Laserfiche WebLink
��� � ��.� <br /> C,g Deck-ArmorT'" Premium Breathable Roof Deck Protection: <br /> 6 9 1 Deck-Armor shall not be left exposed for longer than 30-days after installation <br /> 6.9,2 Deck-Armor shall be installed in compliance with the requirements for ASTM D226 <br /> underiayment in FBC Sections 1507 for the type of prepared roof covering to be installed <br /> 6.9 3 Fasteners shall be plastic cap corrosion resistant nails or staples with pl<3stic caps. <br /> 6.9 4 Install a leak barrier of WeatherWatch� or StormGuard� at vulnerable leak areas, including <br /> but not limited to eaves, valleys, rakes, skylights and dormers. At eavE�s and valleys, install <br /> the leak barrier prior to installation of Deck-Armor�"'. Along the rake, install Deck-Armor'"' <br /> leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the Deck- <br /> Armor'"' and exposed decking. At other areas, install the leak barrier over the Deck- <br /> Armor�"' . <br /> 6.9 5 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth <br /> Edition, use is limited to System 1, Option 4, Section 3.02D in place of the "No. 30" felt. In <br /> this case, the "starter strip" and "full-width-sheet" referenced therein shall be proportionate <br /> to the width of the Deck-ArmorT`" product. <br /> 6.10 For non-tile roof installations: <br /> 6 10 1 Standard Installation with Single Layer, roof slope > 4:12 <br /> 6.10.1 1 Starting at the eave, fasten the eave edge and 6-inch wide end-laps 6-inch o c. Fasten in <br /> the field of the roli 12-inch o.c. in two, equally spaced, staggered center rows <br /> 6.10.1 2 Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum <br /> 6-inch end-laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, <br /> staggered center rows in the field Ensure all end laps are staggered at least 3-feet apart. <br /> 6 10 2 Standard Installation with Double Layer; 2� 12 < roof slope < 4:12 <br /> 6 10.2 1 Starting at the eave, fasten the eave edge and 6-inch wide end-laps 6-inch o.c Fasten in <br /> the field of the roll 12-inch o.c. in two, equally spaced, staggered cente°r rows <br /> 6 10.2.2 Continue upslope in a similar manner, with minimum 28 5-inch side-laps and minimum 6- <br /> inch end-laps. Fasten 6-inch o c. along the low edge and end laps arid 12-inch o c. in two, <br /> equally spaced, staggered center rows in the field. Ensure all end laps are staggered at <br /> least 3-feet apart. <br /> 6 10 3 Special Installation, roof slope > 2:12 <br /> 6.10 3.1 Starting at the eave, fasten the eave edge and 12-inch wide end-laps 6-inch o c Fasten in <br /> the field of the roll 12-inch o c. in two, equally spaced, staggered center rows <br /> 6 10 3.2 Continue upslope in a similar manner, maintaining minimum 6-inch shde-laps and minimum <br /> 12-inch end-laps. Fasten 6-inch o.c. in the laps and 12-inch o.c iri two, equally spaced, <br /> staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart. <br /> E.10 3 3 Apply butyl adhesive based seam tape or waterproof cloth duct tape over all laps and <br /> fasteners <br /> Exterior Research and Design, LLC. Evaluation Report 01506.04.08 <br /> Certificate of Authorization #9503 FL10626 <br /> Date of Issuance: 04/25/2008 <br /> Page8of9 <br />