Wind Load Bracinp <br /> All option code assemblies listed in Table 1 of this report are braced on the inside of the <br /> doors with three inch horizontal spanning U-bars. Each U-bar is made of either 18-gage or <br /> 20-gage ASTM A653-00 steel with a minimum yield strength of 80 ksi and are finished with <br /> an ASTM A525 minimum G-40 galvanized coating. The gage and quantity of U-bar braces <br /> varies depending on the amount of windload resistance required and the height of the door <br /> In addition to three-inch horizontal spanning U-bars, some of the option code assemblies <br /> listed in Tables 1 and 2 of this report are braced with vertical aluminum posts made up of <br /> 0.125-inch thick 6063-T6 aluminum alloy The post is a telescoping post assembly The <br /> outer member outside diameter is 1 75" wide x 4.00" long. The inner member outside <br /> diameter is 1 47" wide x 3 72" long <br /> 6. INSTALLATION <br /> All option code assemblies listed in this report are to be installed in accordance with the <br /> most recent manufacturer's published installation instructions/drawings and this report. <br /> The most recent manufacturer's installation instructions/drawings shall be strictly adhered <br /> to and a copy of these instructions/drawings shall be available at all times on the job site <br /> during installation. <br /> 7. ALLOWABLE TRANSVERSE WIND LOADS <br /> Design wind load pressures for garage doors shall be determined in accordance with <br /> section 1609 of the 2007 Florida Building Code and shall not exceed the allowable <br /> transverse wind loads shown in the following tables. <br /> Table 1: Models 8000/8100/8200 Allowable Transverse Wind Loads and Impact Rating <br /> Windload Maximum Size Positive Negative Glazing Door Impact <br /> Specification Design Design Available Resistant <br /> O tion Code Width Hei ht PSF PSF Reinforcement Yes/No Yes/No <br /> 1100 9'-0" 14'-0" 15.90 18.20 3", 20 gage U-bars Yes No <br /> 1101 9'-0" 14'-0" 22.90 26.30 3", 20 gage U-bars Yes No <br /> 1102 9'-0" 14'-0" 26.90 30 80 3", 20 gage U-bars Yes No <br /> 1103 9'-0" 14'-0" 35 70 41 00 3", 20 gage U-bars Yes No <br /> 1104�'� 9'-0" 14'-0" 46 00 52.00 3", 20 gage U-bars Yes Yes <br /> 1120 16'-0" 14'-0" 12.40 13.80 3", 20 gage U-bars Yes No <br /> 1121 16'-0" 14'-0" 15.30 17 00 3", 20 gage U-bars Yes No <br /> 1122 16'-0" 14'-0" 23.00 25 00 3", 20 gage U-bars Yes No <br /> 1123�'� 16'-0" 14'-0" 30 00 33.50 3", 18 gage U-bars Yes Yes <br /> 1124�'� 16'-0" 14'-0" 34 40 38.30 3", 18 gage U-bars Yes Yes <br /> 1125�'� 16'-0" 14'-0" 46 00 52.00 3", 18 gage U-bars Yes Yes <br /> 1140 18'-0" 14'-0" 12.40 13 80 3", 20 gage U-bars Yes No <br /> 1141 18'-0" 14'-0" 18.50 20 70 3", 18 gage U-bars Yes No <br /> 1142�'� 18'-0" 14'-0" 34 40 38 30 3", 18 gage U-bars Yes Yes <br /> 1143�'� 18'-0" 8'-0" 34 40 38 30 3", 20 gage U-bars +(1) Aluminum Post Yes Yes <br /> 1144�'� 18'-0" 8'-0" 46 00 52.00 3", 20 gage U-bars +(1) Aluminum Post Yes Yes <br /> Note 1 The option code assemblies indicated in Table 1 have optional glazing that has been tested for impact <br /> resistance, and therefore may be used with optional glazing in the wind borne debris region. <br /> Page 3 of 5 Wayne-Dalton <br />