8. SUBSTANTIATING DATA <br /> 1. Test Report Numbers ETC-06-976-18504.0, ETC-06-976-18504.1, and CTLA1911W 6 in <br /> accordance with ANSUDASMA 108-2002 for transverse wind load and <br /> ANSI/DASMA 115-2005 for large missile impact resistance by ETC Laboratories, <br /> 297 Buell Road, Rochester, N.Y and Certified Testing Laboratories, 7252 <br /> Narcoossee Rd Orlando, FI 32822. <br /> 2. Test Reports CTLA 1672W, CTLA 1672W 1, CTLA1672W 3, CTLA1734W, CTLA <br /> 1734W-1,and CTLA 1734W 2 tested in accordance with Miami-Dade County Protocol TAS- <br /> 202 for transverse wind load and TAS-201 and TAS-203 for large missile impact and cyclic <br /> resistance by Certified Testing Laboratories, 7252 Narcoossee Rd. Orlando, FI 32822. <br /> 3. Installation drawings and installation instructions prepared by Wayne-Dalton Corporation <br /> for each option code assembly listed in Table 1 of this report. <br /> 9. CODE REFERENCES <br /> Florida Buildinp Code 2007 Edition <br /> Section 1609 Wind Loads <br /> Section 1714.5.3 1 ANSI/DASMA 108 <br /> 10. REPORT SUMMARY <br /> Upon review of the data submitted by Wayne-Dalton, it is my opinion that the models as <br /> described in this report conform with or are a suitable alternative to the code standards and <br /> sections in the Florida Building Code 2007 edition listed in section 9 of this report. <br /> 11. LIMITATIONS <br /> Any reference in this report to the manufacturer's "most recent" information is a direct <br /> reference to the most recent information submitted by Wayne-Dalton to the Florida Building <br /> Commission as part of their Florida Product Approval application for the option code <br /> assemblies listed in Table 1 of this report. <br /> This evaluation report and the most recent installation instructions, when required by the <br /> buifding official, shall be submitted at the time of permit application. <br /> The design of the supporting structural elements shall be the responsibility of the design <br /> professional for the building structure and in accordance with current building codes for the <br /> loads listed in Table 1 of this report. <br /> The doors shall not be located in areas where the transverse wind loads exceed the <br /> allowable loads shown in Table 1 of this report. <br /> The garage door assemblies listed in Table 1 of this report are not approved for use in the <br /> "High Velocity Hurricane Zone" as defined in the Florida Building Code. <br /> Page 4 of 5 Wayne-Dalton <br />