My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11964
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11964
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/16/2013 11:27:34 AM
Creation date
1/16/2013 11:27:28 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA MEDICAL CLINIC
Building Department - Doc Type
Permit
Permit #
11-11964
Building Department - Name
FLORIDA MEDICAL CLINIC
Address
38135 MARKET SQUARE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' � Mr. Joseph L. Oliveri <br /> Page 3 of 6 <br /> February 17, 2011 <br /> Re: Facility Name: Florida Medical Clinic Special Procedures Center <br /> Project Name: Expansion <br /> Client Code/File-Project-Submission Number: 14/221-101-005 <br /> GENERAL <br /> G-1 Provide an Infection Control Risk Assessment (ICRA) signed by an infection <br /> control representative for the existing outpatient facility adjacent to the new <br /> construction. The Guidelines for Design and Construction of Hospitals and Health <br /> Care Facilities, (The Guidelines, 2006 edition), Chapter 1.5-1.2.1 <br /> ARCHITECTURAL <br /> A-1 Sheet T2: Under the heading "APPLICABLE CODES" reference the 2006 edition <br /> of NFPA 101 Life Safety Code. <br /> A-2 Sheet D1 b: Provide a fire rated polyethylene barrier separating the demolition to <br /> be done in the existing corridor where door openings will be filled in. <br /> A-3 Sheet D1b: Provide a fire rated polyethylene barrier or temporary wall separating <br /> the work adjacent to existing Computer Room 161 during Phase 1 of <br /> construction <br /> A-4 Sheet LS3: Provide a wall-type designation for a 1-hour fire rated barrier in the <br /> LIFE SAFETY LEGEND. <br /> A-5 Sheet LS3: Provide a 1-hour rated fire/smoke barrier separating all smoke <br /> compartments. NFPA 101, Chapter 20.3.7.5 <br /> A-6 Sheet LS3: Show the 1-hour fire/smoke compartment barrier as tracking on the <br /> back wall of the Business Office/Medical Records 113 and show the rest of the <br /> walls in that room as 1-hour fire rated. NFPA 101, Chapter 20.3.7 5 <br /> A-7 Sheet LS3: Provide an exit sign on the ambulatory surgical center (ASC) side of <br /> Door 118 leading to the existing corridor. NFPA 101, Chapter 20 2.4.1 <br /> A-8 Sheet LS3: Show different wall type designations for the 1-hour fire rated <br /> barriers and the fire/smoke barrier in Equipment Storage 151 and General <br /> Equipment Storage 150. <br /> A-9 Sheet LS3: Show the location of fire extinguishers on the overall Life Safety Plan. <br /> NFPA 101, Chapter 20.3.5.3 <br /> A-10 Sheet A1 b: Provide a 20-minute fire rated door at Door 110b located within the <br /> smoke compartment barrier and coordinate with the door schedule. <br />
The URL can be used to link to this page
Your browser does not support the video tag.