My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11964
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11964
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/16/2013 11:27:34 AM
Creation date
1/16/2013 11:27:28 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA MEDICAL CLINIC
Building Department - Doc Type
Permit
Permit #
11-11964
Building Department - Name
FLORIDA MEDICAL CLINIC
Address
38135 MARKET SQUARE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� ' Mr. Joseph L. Oliveri <br /> Page 5 of 6 <br /> February 17, 2011 <br /> Re: Facility Name: Florida Medical Clinic Special Procedures Center <br /> Project Name: Expansion <br /> C(ient CodelFile-Project-Submission Number: 14/221-101-005 <br /> M-2 Sheet M2.0: Provide a fire/smoke damper at the duct penetration of the <br /> fire/smoke barrier wall at Equipment Storage #151 and General Equipment <br /> Storage#150. 1052. See Florida Mechanical Code 2007 Chapter 607.5.4. <br /> M-2 Sheet M2.0: The location of Medical Gas Room#139 does not match with <br /> architecture plan. Revise it. <br /> M-3 Sheet M2.0: Indicate direction of air flow for Med Prep #133, Soiled Work#136 <br /> and Soiled Utility#1134. <br /> M-4 Sheet M2.0� Provide a minimum 1 hour fire wall for vacuum pump room and add <br /> fire dampers on duct accordingly. See NFPA 99 2005 Chapter 5.1.3.6.1.1(2) <br /> M-5 Sheet P5: Provide clinical sink in Soiled Wark Room #125. See AIA Guidelines <br /> 2006 Chapter 3.7.2.5.4. <br /> M-6 Sheet P0.1� Provide back flow preventer and indirect waste by air gap for Ice <br /> Maker. <br /> M-7 Provide the location of water hammer arrestors on the plan or riser diagram. <br /> M-8 Sheet MG3: Provide missing key notes 9 on the plan. <br /> M-9 Sheet MG4: Relocate area medical gas alarm panel (AAP-1) from corridor to <br /> nursing station or other location that will provide for surveillance. See NFPA 99 <br /> 2005 Chapter 5.1.9.3.1. <br /> M-10 Sheet MG5: Route receives tank drain to floor drain. <br /> M-11 Sheet MGS: Provide shutoff valves at the discharge of vacuum pump to isolate <br /> each vacuum pump for maintenance or repair See NFPA 99 2005 Chapter <br /> 5.1.3.6.1.2(3). <br /> FIRE PROTECTION <br /> FP-1 Sheet FPO: Indicate the date for the water flow test, which shall be within 180 <br /> days of construction document submission. <br /> FP-2 Provide missing fire protection specification for AHCA review. <br /> FP-3 Provide quick response sprinkler heads for the project. <br />
The URL can be used to link to this page
Your browser does not support the video tag.