Laserfiche WebLink
September 16,2004 DN-7001 •A1-380 <br /> � o NOT-BG12LX <br /> JN QT 1 F 1 E R Addressable Manual Pull Station <br /> for FireWarden-100 <br /> Section. Addressable <br /> GENERAL Patented, U.S. Patent No. D428,351; 6,380,846 <br /> U.S. Pateni Pend/ng; 091686,286 <br /> The NOTIFIER NOT-BG12LX is a state-of-the-art, dual-ac- <br /> tion (i.e., requires two motions to activate the station) pull <br /> station that includes an addressable interface(mounted in- <br /> side)for NOTIFIER's addressable FireWarden-100 fire alarm <br /> control panel. Because the NOT-BG12LX is addressable, o L <br /> the control panel can display the exact location of the acti- <br /> vated manual pull station.This leads fire service personnel LISTED <br /> quickly to the location of the alarm. <br /> FEATURES sss2 <br /> • Aesthetically pleasing, highly visible,dual-action design. <br /> • Meets ADA 5 Ib. maximum pull force. <br /> • Easily operated(dual-action). -h..�-��. <br /> • Attractive shape and textured finish. - �, � <br /> • Mounts, semi-flush, to a standard single-gang (2.125" '�.� , <br /> [5.398 cm] minimum depth), double-gang, or 4 0"(10.16 � <br /> cm)square electrical box. � <br /> • When the handle latches in down position,the word"AC- � <br /> TIVATED"appears at the top of the handle in bright yellow � <br /> to ciearly indicate the station has been operated. <br /> • Key/lock reset; needs only a 1/4-turn to lock/unlock. i� '? <br /> t <br /> • Includes Braille text on station handle. :, <br /> • Captive screw terminals wire-ready for easy connection ':�, <br /> to SLC loop(accepts up to 12 AWG/3 1 mm2 wire). � <br /> • Optional trim ring (BG-TR). � <br /> • Meets UL 38, Standard for Manually Actuated Signaling ; <br /> Boxes. � <br /> • Maintenance personnel can open station (for inspection � <br /> and testing)without causing an alarm condition. • � <br /> • Built-in bicolor LED,which is visible through the handle of 4�, <br /> the station, flashes red in normal operation and latches n - �• ---- -�-=n=-��-, �-.:,.;: <br /> on steady red when in alarm. m <br /> ENGINEERING SPECIFICATIONS <br /> Manual Fire Alarm Stations shall be non-code, with a key- The NOT-BG12LX <br /> operated reset lock in order that they may be tested,and so Addressable Manual Pull Station <br /> designed that after actual Emergency Operation,they can- <br /> not be restored to normal except by use of a key. An oper- by the Americans with Disabilities Act(ADA)or per national/ <br /> ated station shall automatically condition itself so as to be local requirements. Manual Stations shali be Underwriters <br /> visually detected as activated.Manual stations shall be con- Laboratories listed. <br /> structed of red-colored LEXANO(or polycarbonate equiva- <br /> lent) with clearly visible operating instructions provided on Manual stations shall connect with two wires to one of the <br /> the cover The word FIRE shall appear on the front of the control panel SLC Ioops.The manual station shall,on com- <br /> stations in white letters, 1.00 inches(2.54 cm)or larger. Sta- mand from the control panel, send data to the panel repre- <br /> tions shall be suitable for surface mounting on matching senting the state of the manual switch.Manual stations shall <br /> backbox SB-10 or SB-I/O;or semi-flush mounting on a stan- provide address setting by use of rotary decimal switches. <br /> dard single-gang, double-gang, or 4 0" (10.16 cm) square ELECTRICAL SPECIFICATIONS <br /> electrical box,and shall be installed within the limits defined <br /> Normal operating voltage:24 VDC. <br /> LEXANO is a registered trademark of GE Plastics, Maximum SLC loop voltage:28.0 VDC <br /> a subsidiary of General Electric Company Maximum SLC loop current:230 NA. <br /> NOTIFIER�is a Honeywell company <br /> This document is not intended to be used for installation purposes.We try to keep our '�O 9001 <br /> product information up-to-date and accurate. We cannot cover all specific applications <br /> or anticipate all requirements.All specifications are subject to change without notice.For ��r <br /> more information, contact NOTIFIER. Phone; (203) 484-7161 FAX. (203)484-7115 ■•�•'+'+�� <br /> ENCINEERIII�!MAMUFACIOIINC <br /> �J N OTI F 1 E R'' �2 Clintonville Road,Northford,Connecticut 06472 Q U A L I T l S y S T E M S <br /> DN-7001•09/16l04 — Page 1 of 2 <br />