Laserfiche WebLink
SYSTEM SPECIFICATIONS <br /> System Capacity is.s5° (42.29 cm.) wide x 5.20° (13.34 cm.) deep. Trim Ring <br /> • Intelligent Signalling Line Circuits. � RR-CE-B).22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. <br /> ... .............. <br /> • Addressable device capacity... ... ..... ......... •••198 Shipping Specifications <br /> • Programmable software zones........ .............. ....99 . <br /> Weight:26.9 Ibs. (12.20 kg.) Dimensions: 20.00"(50.80 cm.) <br /> • Annunciators............... .. ..... ... ........... •.32 high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. <br /> Electrical Specifications Temperature and Humidity Ranges <br /> AC Power• FireWarden-100-2: 120 VAC, 60 Hz, 3.0 amps. This system meets NFPA requirements for operation at 0 - <br /> FireWarden-100-2(E). 240 VAC, 50 Hz, 1.5 amps. Wire size: 49°C/32 - 120°F and at a relative humidity 93% t 2% RH <br /> minimum 14 AWG (2.00 mmz)with 600 V insulation. (noncondensing) at 32°C t 2°C (90°F t 3°F). However, the <br /> Battery• Two 12 V 18AH lead-acid batteries. Battery charger useful life of the system's standby batteries and the electronic <br /> capacity: 7 - 18 AH FireWarden-100-2 cabinet holds maxi- components may be adversely affected by exVeme tempera- <br /> mum of two 18 AH batteries. ture ranges and humidity. Therefore, it is recommended that <br /> Communication Loop: Supervised and power-limited. this system and its peripherals be installed in an environment <br /> with a normal room temperature of 15-27°C/60-80°F <br /> Notification Appliance Circuits: Each terminal block pro- <br /> vides connections for two Style Y (Class B) or one Style Z NFPA Standards <br /> (Class A) for a total of four Style Y (Class B) or two Style Z <br /> (Class A) NACs. Maximum signaling current per circuit: 2.5 The FireWarden-100-2 complies with the following NFPA 72 <br /> amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 Fire Alarm Systems requirements: <br /> UL listed)for Style Y(Class B) NAC. Refer to panel documen- -LOCAL (Automatic, Manual, Waterflow and Sprinkler <br /> tation and Notifier Device Compatibility Document for listed Supervisory). <br /> compatible devices. -AUXILIARY(Automatic, Manual and Waterflow) (requires <br /> Two Programmable Relays and One Fixed Trouble Relay: 4XTM) <br /> Contact rating:2.0 amps @ 30 VDC(resistive),0.5 amps @ 30 _REMOTE STATION (Automatic, Manual and Waterflow) <br /> VAC(resistive). Form-C relays. <br /> (Where a DACT is not accepted, the alarm, Vouble and <br /> Special Application Power(24 VDC Nominal): Jumper supervisory relays may be connected to UL 864 listed <br /> selectable (JP4)for conversion to resettable power output. Up transmitters. For reverse polarity signaling of alarm and <br /> to 0.5 amps total DC current available from each output. trouble,4XTM is required.) <br /> Power-limited. -PROPRIETARY(Automatic,Manual and Watertlowj <br /> Four-Wire Resettable Special Application Smoke Detector -CENTRAL STATION (Automatic, Manual and Waterflow, <br /> Power(24 VDC nominal): Up to 0.5 amps for powering four- and Sprinkler Supervised). <br /> wire smoke detectors. Power-limited. Refer to Notifier Device _AUTO DETECTOR SELF TEST <br /> Compati6ility Documenf for listed compatible devices. <br /> Remote Sync Output: Remote power supply synchronization pgency Listings and Approvals <br /> output. Nominal special application power 24 VDC. Maximum <br /> current:40 mA. End-of-Line Resistor•4.7K ohm.Output linked The listings and approvals below apply to the basic FireWar- <br /> to NAC 1 control.Supervised and power-limited. den-100-2 control panel. In some cases,certain modules may <br /> not be listed by certain approval agencies,or listing may be in <br /> Telephone Intertace: Requires dedicated business tele- Process.Consult factory for latest listing status. <br /> phone number with a minimum of 7 volts DC.Obtain dedicated <br /> phone line directly from your local phone company.Do not use • UL.S635 <br /> shared phone lines or PBX(digital)type phone line extensions. • FM approved <br /> • CSFM•7165-0028:235 <br /> Cabinet Specifications • MEA. 120-O6-E,Volume 2 <br /> Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x <br /> 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x <br /> FireWarden� and Notifier� are registered Vademarks of Honeywell <br /> International Inc.Microsoft�and Windows�are registered Vademarks of the <br /> Microsoft Corporation. <br /> m2007 by Honeywell International Inc.All rights reserved.Unauthorized use <br /> of this document is sVictly prohibited. <br /> '�O �oo` This document is not intended to be used for installation purposes. <br /> 1 We try to keep our product information up-to-date and accurate. <br /> We cannot cover all specific applications or anticipate all requirements. <br /> �y���pp g Mpy�ry��yp�� All specifications are subject to change without notice. <br /> an���Tr srsrE�s MadeintheU.S.A. <br /> For more information,contact Notifier.Phone:(203)484•7161,FAX.(203)484-7118. <br /> www.notifier.com <br /> Page 4 of 4—DN-7101.A•09l2'I/07 <br />