Laserfiche WebLink
�S. <br /> �mplex TrueAlarrri Analog Sensing <br /> UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensars — Photoelectric, <br /> MEA (NYC)Acceptance* lonization, and Heat; Standard Bases and Accessories <br /> � <br /> �; . <br /> TrueAlarm analog sensing provides: I�i�g�., u��V�,! <br /> • Digital transmission of analog sensor values via �"'�: ,.�'�; <br /> IDNetTM or MAPNET II�two-wire communications** � � fi=� <br /> For use with the following Simplex°products: �+ � <br /> ��. <br /> • 4010 and 4100U Series control panels;and 4008 Series <br /> control panels with reduced feature set(refer to data "'� <br /> sheet S4008-0001 for details) <br /> • 4020,4100,and 4120 Series control panels,Universal <br /> Transponders and 2120 TrueAlarm CDTs equipped for 4098-9714 TrueAlarm Photoelectric <br /> MAPNET II operation Sensor Mounted in Base <br /> Fire alarm control panel provides: <br /> • Peal<value logging allowing accurate analysis of each � " • • <br /> sensor for individual sensitivity selection <br /> � Digital Communication of Analog Sensing. <br /> • Sensitivity monitoring satisfying NFPA 72 sensitivity TrueAlarm analog sensors provide:an analog <br /> testing requirements;automatic individual sensor measurement digitally communicated to the host control <br /> calibration check verifies sensor integrity panel using Simplex addressable communications.At the <br /> • Automatic environmental compensation,multi-stage control panel,the data is analyzed and an average value is <br /> alarm operation,and display of sensitivity directly in determined and stored.An alarm or other abnormal <br /> percent per foot condition is determined by comparing the sensor's present <br /> • Ability to display and print detailed sensor information value against its average value and time. <br /> in plain English language Intelligent Data Evaluation.Monitoring each sensor's <br /> PhotoelectriC smoke sensors provide: average value provides a continuously shifting reference <br /> • Seven levels of sensitivity from 0.2%to 3.7% point.This software filtering proce;ss compensates for <br /> environmental factors(dust,dirt,etc.)and component <br /> Heat sensors provide: aging,providing an accurate refere-nce for evaluating new <br /> • Fixed temperature sensing activity.With this filtering,there is a significant reduction <br /> • Rate-of-rise temperature sensing in the probability of false or nuisance alarms caused by <br /> • Utility temperature sensing <br /> shifts in sensitivity,either up or down. <br /> lonization smoke sensors provide: Control Panel Selection.Peak activity per sensor is <br /> . o 0 o stored to assist in evaluating speciiic locations.The alarm <br /> Three levels of sensitivity;0.5/o,0.9/o,and 1.3/o set point for each TrueAlarm sensor is determined at the <br /> General features: host control panel,selectable as more or less sensitive as <br /> • UL listed to Standard 268 the individual application requires. <br /> • Louvered smoke sensor design enhances smoke Timed/Multi-Stage Selection. Sensor alarm set points <br /> capture by directing flow to chamber;entrance areas can be programmed for timed auto matic sensitivity <br /> are minimally visible when ceiling mounted selection(such as mare sensitive ai:night,less sensitive <br /> • Designed far EMI compatibility during day). Conh•ol panel programming can also provide <br /> multi-stage operation per sensor.For example,a 0.2% <br /> • Magnetic test feature is provided level may cause a warning to prompt investigation while a <br /> • Optional accessories include remote LED alarm 2.5%level may initiate an alarm. <br /> indicator and output relays Sensor Alarm and Trouble LED Indication.Each <br /> Additional base reference: sensor base's LED pulses to indicate communications <br /> • For isolator bases,refer to data sheet 54098-0025 with the panel.If the control panel determines a sensor is <br /> • For sounder bases,refer to data sheet 54098-0028 in alarm,or is dirty or has some other type of trouble,the <br /> • For photo/heat sensors,refer to data sheet S4098-0024 details are annunciated at the control panel and that sensor <br /> (single address)and S4098-0033 (dual address) base's LED will be turned on steadily.During a system <br /> alarm,the control panel will control the LEDs such that <br /> " These products have been approved by the Califomia State Fire Marshal(CSFM)pursuant to ari L,ED IriCI1C8tlri a trouble will return to UISlri t0 1101 <br /> Section 13144.1 of the California Health and Safety Code.See CSFM Listings g p g j� <br /> 7272-0026:218,7271-0026:231,7270-0026:216,and 7300-0026:217 for allowable values identify the alarmed sensors. <br /> and/or conditions concerning material presented in this document.It is subject to <br /> re-examination,revision,and possible cancellation.Accepted for use—City of New York "TrueAlarm analog sensors are protected by one or more of the following U.S.Patents: <br /> Department of Buildings—MEA35-93E.Additional listings may be applicable,contact your 5,155,468;5,173,683;5,400,014;5,543,777;5,710,541;D383,407;D388,352;D392,573. <br /> local Simplex product supplier for the latest status.Listings and approvals under Simplex MAPNET II and IDNet addressable communicalions designs are protected by U.S.Patent <br /> Time Recorder Co.are the properly of Tyco Safety Products Westminster No.4,796,025. <br /> S4098-0019-12 8/2008 <br />