My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-12736
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-12736
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2013 1:19:24 PM
Creation date
1/25/2013 1:16:36 PM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
12-12736
Building Department - Name
FLORIDA HOSPITAL ZEPHYRHILLS
Address
7050 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TrueAlarm Sensor Bases and Accessories . - . . <br /> • TrueAlarm sensor bases contain integral addressable <br /> Base mounted address selection: electronics that constantly monitor the status ofthe <br /> detachabie photoelectric,ionization,or heat sensors.Each <br /> • Address remains with its programmed location sensor's output is digitized and transmitted to the system <br /> • Accessible from front(DIP switch under sensor) fire alarm control panel every four seconds. <br /> General features: Since TrueAlarm sensors use the same base,different <br /> • Automatic identification provides default sensitivity sensor types can be easily interchanged to meet specific <br /> when substituting sensor types location requirements. This feature also allows intentional <br /> • Integral red LED for power-on(pulsing),or alarm or sensor substitution during building construction.When <br /> trouble(steady on) conditions are temporarily dusty,instead of covering the <br /> • Locking anti-tamper design mounts on standard outlet smoke sensors(causing them to b��disabled),heat sensors <br /> box may be installed without reprogra�nming the control <br /> panel.Although the control panel will indicate an <br /> • Magnetically operated functional test incorrect sensor type,the heat sensor will operate at a <br /> . default sensitivity providing heat detection for building <br /> protection at that location. <br /> 4098-9792,Standard sensor base <br /> 4098-9789,Sensor base with wired connections for: ' ' <br /> • 2098-9808 Remote LED alarm indicator or 4098-9822 <br /> relay(unsupervised) <br /> Electricai Box Requirements:(boxes are by others) <br /> 4098-9791,Sensor base with supervised relay driver Without relav•4��octagonal or 4��:;quare, 1-1/2��deep; <br /> output(not compatible with 2120 CDT): single gang,z��deep <br /> • Relay operation is programmable and can be manually �n_relav:a'�octagona�or a��square,1-1/2��deep, <br /> operated from control panel with 1-1/2��extension ring <br /> • Use with remote mount 2098-9737 relay a��(�oz mm)syuare sox a��(102 mm)Octagonal Box <br /> • Also includes wired connections for remote LED alarm surface mount reference <br /> indicator or 4098-9822 relay - <br /> • • • • C C � C C <br /> 2098-9737, Remote or local mount supervised relay: <br /> • DPDT contacts for resistive/suppressed loads,power 1-112��(ss mm) <br /> minimum box depth <br /> limited rating of 3 A@ 28 VDC;non-power limited Flush mount reference,mount even with final <br /> rating of 3 A@ 120 VAC(requires external 24 VDC surface,or with up to 1i4"(6.4 mm)maximum recess <br /> coilpower) ,------------------------------------------------� <br /> ;2098-9737 Relay(mounts in 4098-9822 Relay(mounts � <br /> 4098-9822, LED AnnunCiation Relay: ;base electrical box or remotely) iri base electrical box) � <br /> • Activates when base LED is on steady,indicating local � � <br /> alarm or trouble ' ' <br /> • DPDT contacts for resistive/suppressed loads,power � � <br /> � � <br /> limited rating of 2 A@ 28 VDC;non-power limited ' ' <br /> rating of 1/2 A@ 120 VAC,(requires externa124 VDC ; � <br /> coil power) � � <br /> 4098-9832,Adapter plate: ; Relay Size: 2-1/z"X 1-1/2"X 1"(3 75 cubic inches) � <br /> ; (64mmX38mmX25.4mm) i <br /> • Required for surface or semi-flush mounting to � � <br /> � NOTE:Review total wire count,wire size,and accessories � <br /> 4"square electrical box and for surface mounting to � being wired to determine required box volume. � <br /> 4"octagonal box � <br /> ------------------------------------------------� <br /> • Can be used for cosmetic retrofitting to existing 6-3/8" �;.. 6-3/S^(�s2 n,m) -►i <br /> diameter base product � -� <br /> 2098-9808, Remote red LED Alarm � f 4098-9832 Adapter Plate,reauired for <br /> Indicator: ��4�� mounting to urfac mounted boxes <br /> (6.4 mm) and 4"square I�ush box <br /> • Mounts on single gang box <br /> ALARM 4-7/8" 124 mm <br /> (shown in illustration to right) p It-- ( >--►I <br /> 15/16" <br /> (24 mm) p � <br /> £i Simplex <br /> TrueAlarm Bases <br /> � 4098-9789,-9791,8�-9792 <br /> 2 S4098-0019-12 8/2008 <br />
The URL can be used to link to this page
Your browser does not support the video tag.