Company Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
12-12736
Building Department - Name
FLORIDA HOSPITAL ZEPHYRHILLS
Address
7050 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- � � . . . . • . <br /> � TrueAlarm Sensor Bases* <br /> � Model Description Compatibility Mounting Requirements <br /> 4098-9792 Standard Sensor Base, no options Sensors 4098-9714,-9733,&-9717 4"octagonal or 4"square box, 1-1/2"min. <br /> depth;or single gang box,2"min.depth <br /> Sensor Base with connections for Sensors 4098-9714,-9733,&-9717 <br /> 4098-9789 Remote LED Alarm Indicator or 2098-9808 remote LED alarm 4"octagonal or 4"square box <br /> Unsupervised Relay indicator or 4098-9822 relay <br /> Sensor Base with connections for Sensors 4098-9714,-9733,&-9717 Note:Box depth requirements depend <br /> on total wire count and wire size,refer to <br /> 4098-9791 Supervised Remote Relay and 2098-9737 remote relay(supervised) accessories list below for reference. <br /> connections for Remote Alarm 2098-9808 remote alarm indicator or <br /> Indicator or Unsupervised Relay 4098-9822 relay(unsupervised) <br /> �rueAlarm Sensors <br /> Model Description Compatibility Mounting Requirements <br /> 4098 9714 Photoelectric Smoke Sensor <br /> 4098-9717 lonization Smoke Sensor Bases 4098-9792,4098-9789, Refer to base requirements <br /> and 4098-9791 <br /> 4098-9733 Heat Sensor <br /> TrueAlarm Sensor/Base Accessories <br /> Model Description Compatibility Mounting Requirements <br /> Remote Mounting requires 4"octagonal or <br /> Supervised Relay,mounts remote 4"square box, 1-1/2"minimum depth <br /> 2098-9737 or in base electrical box For use with 4098-9791 base Base Mounting requires 4"octagonal box, <br /> 2-1/8"deep with 1-1/2"extension ring <br /> 2098-9808 Remote Red LED Alarm Indicator Single gang box, 1-1l2"minimum depth <br /> on single gang stainless steel plate <br /> Relay,tracks base LED status Bases 4098-9789 and 4098-9791 <br /> 4098-9822 (unsupervised,mounts only in base 4"octagonal box,2-1/8"deep with 1-1/2" <br /> electrical box) e�ension ring <br /> Required for surtace or semi-flush <br /> 4098-9832 Adapter Plate Bases 4098-9792,-9789,&-9791 mounted 4"square box and for surface <br /> mounted 4"octagonal box <br /> "Refer to Installation Instructions 574-707 and Application Manual 574-709 for additional information. <br /> • - . • <br /> General Operating Specifications <br /> Communications and Sensor Supervisory Power MAPNET II or IDNet,auto-select,24-40 VDC wldata,400 NA typical, <br /> 1 address per base <br /> Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG(0.82 mm2 to 2.08 mm2) <br /> Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current <br /> Remote LED Alarm Indicator and Relay Connections Color coded wire leads,18 AWG(0 82 mm2) <br /> UL Listed Temperature Range 32°to 100°F(0°to 38°C) <br /> Operating with 4098-9717 or 4098-9733 32°to 122°F(0°to 50°C) <br /> Temperature Range with 4098-9714 15°to 122°F(-9°to 50°C) <br /> Humidity Range 10 to 95%RH <br /> Smoke Sensor 4098-9714, Photoelectric Sensor Air velocity=0-2000 ft/min(0-610 m/min) <br /> Ambient Ratings 4098-9717, lonization Sensor Air velocity=0-200 ft/min(0-61 m/min);Altitude is up to 8000 ft(2.4 km) <br /> Housing Color Frost White <br /> 4098-9791 Base With Supervised Remote Relay 2098-9737(see page 2 for contact ratings) <br /> Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC) <br /> Supervisory Current 270µA,from 24 VDC supply <br /> Alarm Current with 2098-9737 Relay 28 mA,from 24 VDC supply <br /> 4098-9822 Unsupervised Relay,Requirements for Bases 4098-9789 and 4098-9791 (see page 2 for contact ratings) <br /> Externally Supplied Relay Coil Voltage 18-32 VDC(nominal 24 VDC) <br /> Supervisory Current Supplied from communications <br /> Alarm Current 13 mA from separate 24 VDC supply <br /> 7yco u n registered trademark of Tyco Intemationa!Services GMBH m�d is used imder lrcense.Sinrplex,the Simplex logo,TrueAlm•m,IDNet,and MAYNET ll m�e trnderaarks of <br /> Tyco Liternatronal Lld mrd its affilintes nnc!nre used under lrcense.NFPA 71 and Natronnl Fire Alnrnr Code are registered trndemnrks of the Nn'ionn!Fire Protectiw�Associntion <br /> �vFPA). <br /> £�Simplex Tyco Safety Products Westminster•Westminster,MA•01441-0001•USA S4098-0019-12 8/2008 <br /> � www.tycosafetyproducts-usa-wm.com <br /> C�2008 Tyco Safety Producrs Westnunster Al!rights reserved Al!specrfrcations and other ii formation shotivn were cz�rrent ns of doc7m7ent revrsion dnte and are subject to clrange without nohce. <br />
The URL can be used to link to this page
Your browser does not support the video tag.