��cr� <br /> Tyco Suppression <br /> Systems . <br /> ANSULINCORPORATED � <br /> S��� MARINETTE,W554E 3-2542 <br /> IS09001REGISTERED �"^^^'V.ansul.com <br /> GENERAL BULLETIN NO. 4260 <br /> Date: May 23, 2000 <br /> To: All Authorized Restaurant System Distributors and OEM's <br /> From: Dave Pelton — Market Development Manager <br /> Subject: PIRANHAO Fire Suppression Systems Fire Sprinkler Connection <br /> Since the commercial introduction of PIRANHA Water-Assisted Suppression Systems back in January `98 we <br /> have been working hard to provide you with the best and most advanced restaurant fire suppression system <br /> i� t�s indus#r,�. <br /> To that end we are pleased to announce that connection to an alternative water supply source such as a fire <br /> sprinkler system is permitted. Noted below is an overview of the requirements. <br /> Before considering any PIRANHA dedicated waterline connection, make certain the connection and the water <br /> source to be used, is adequate for the number and size of PIRANHA system tank(s) needed. The water source <br /> connection and the dedicated waterline for the PIRANHA system, must be designed and installed in <br /> accordance with the appropriate NFPA standard(s) (i.e., NFPA 13—sprinkler waterline connection; NFPA 17A <br /> & NFPA 96 — domestic waterfine connection), the UL 300, PIRANHA Design, fnstallation, and Maintenance <br /> Manual (P/N 423385), and the authority having jurisdiction. <br /> NOTE:The piping requirements in NFPA 13 need ONLY be followed, when the PIRANHA dedicated <br /> waterline is connected to a wet pipe sprinkler system, and apply only to the waterline portion of <br /> the PIRANHA system. The requirements in NFPA 13 DO NOT apply to the PIRANHA system or <br /> the waterline connection when the dedicated waterline is connected to the domestic water supply. <br /> The PIRANHA system has been tested, evaluated, and listed to be used WITHOUT any additional back-flow <br /> prevention needed. However, if the PIRANHA system is to be connected to an existing sprinkler system, or is <br /> to be included as an addition to a sprinkler system currently being designed or under construction, make certain <br /> all back-flow prevention, existing or intended, is reviewed and approved prior to PIRANHA system installation <br /> by the appropriate authority having jurisdiction. <br /> • "ONLY" connections to wet pipe sprinkler systems are acceptable. Gry pipe and pre-action type sprinkler <br /> systems are NOT PERMITTED for use with PIRANHA. <br /> • The dedicated PIRANHA system waterline tap to the sprinkler system must be made by an appropriately <br /> licensed sprinkler fitter/contractor_ All pipe, fittings, and hangers from the sprinkier tap/connection to the <br /> PIRANHA system water valve in the ANSUL AUTOMANo Regulated Release Assembly and/or Regulated <br /> Actuator Assembly(s) must be made in accordance with the "applicable" requirements of NFPA 13. Use of <br /> plastic pipe and fittings for this connection is not acceptable. <br /> • For fire sprinkler system connection the minimum PIRANHA dedicated waterline pipe or tube size must be <br /> 1". Multiple PIRANHAtank systems may require larger size pipe as required. <br />