FDM'I(A� Dl1aI MOI11t01' MOdl1Ie —161.002/23/3(AFP-200:FMM-1/-101, FZM-1) <br /> The FDM-1(A)Dual Monitor Module is intended for use in intelli- —161.002/42/1 (NFS-640:FMM-1/-10i) <br /> gent, two-wire systems. It provides two independent iwo-wire • Lloyd's Regfster: <br /> initiating device circuits (IDCs) at two separate, consecutive —03/60011/Ei (FMM-1/-101, FZM-i) <br /> • addresses. It is capable of monitoring normally open contact fire _g4/60004/E2(AFP-200:except FDM-1) <br /> alarm and supervisory devices; or either normally open or nor- <br /> mally closed security devices. The module has a single panel- —02/60007(NFS-640:FDM-7) <br /> controlled LED. • FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 <br /> NOTE:The FDM-1(A)provides two Style B(Class B)IDC circuits (NFS2-3030) <br /> ONLY Sryle D(C/ass A)IDC circuits are NOT supported in any <br /> aPproar;o�. Product Line Information <br /> FDM-1(A)SPECIFlCATIONS NOTE:A"suffix indicates ULC-listed model. <br /> Normal operating voltage range: 15 to 32 VDC. FMM=1'(A): Monitor module. <br /> Maxlmum current draw:6.4 mA(LED on) FMM-101(A): Monitor module,miniature. <br /> Average operating current:750 NA(LED flashing). FZM-1(A): Monitor module,two-wire detectors. <br /> Maximum IDC wiring resistance: 1,500 ohms. F,DM-1(A):Monitor module,dual,two independent Class B cir- <br /> Maximum IDC Voltage: 11 Volts. cuits. <br /> Maximum IDC Current:240 NA SMB500:Optional surface-mount backbox. <br /> EOL resistance:47K ohms. NOTE: See installation instructions and refer to the SLC Wiring <br /> Manual,PN 51253. <br /> Max(mum SLC Wfring resistance:40 Ohms. <br /> Temperature range:32°to 120°F(0°to 49°C). <br /> Humidity range: 10%to 93%(non-condensing). <br /> Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x <br /> 2.125'(5.398 cm)deep. <br /> FDM-1(A) AUTOMATICADDRESSING <br /> The FDM-1(A)automatically assigns itself to two addressable <br /> points, starting with the originai address. For example, if the <br /> FDM-1(A) is set to address "26", then it will automatically <br /> assign itself to addresses"26"and"2T'. <br /> NOTE:"Ones"addresses on the FDM-1(A)are 0,2,4,6,or 8 only. <br /> Terminals 6 and 7 use the first address,and termrnals 8 and 9 use <br /> the second address. <br /> QCAUTION: <br /> Avoid duplicating addresses on the system. , <br /> Installation <br /> FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly <br /> to a standard 4" (10.16 cm) square, 2.125" (5.398 cm)deep, <br /> eiectrical box.They may aiso be mounted to the SMB500 sur- <br /> face-mount box. Mounting hardware and installation instruc- <br /> tions are provided with each module. All wiring must conform <br /> to applicable local codes, ordinances, and regulations. These <br /> modules are intended for power-limited wiring only. <br /> The FMM-101(A)module is intended to be wired and mounted <br /> without rigid connections inside a standard electrical box. All <br /> wiring must conform to applicable local codes,ordinances,and <br /> regulations. <br /> Agency Listings and Approvals <br /> In some cases, certain modules may not be listed by certain <br /> approval agencies, or listing may be in process. Consult fac- <br /> tory for latest listing status. <br /> • UL:S635 <br /> • ULC:S635 <br /> • FM Approved <br /> • CSFM:7300-0028:0219 <br /> • MEA:457-99-E <br /> • U.S.Coast Guard: <br /> DN-6720:C•10/O6/2010—Page 3 of 4 <br />