My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-12801
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-12801
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2013 1:03:56 PM
Creation date
1/28/2013 12:59:33 PM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA MEDICAL CLINIC
Building Department - Doc Type
Permit
Permit #
12-12801
Building Department - Name
FLORIDA MEDICAL CLINIC
Address
38135 MARKET SQUARE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. FMM-101(A) Mini Monitor Module D(mensions: 1.3" (3.302 cm) high x 2 75° (6.985 cm)wide x <br /> 0.65"(1.651 cm)deep. <br /> • Built-in type identification automatically identifies this device <br /> as a monitor module to the panel. Wire length:6"(1524 cm)minimum. <br /> • Powered directly by two-wire SLC loop.No additional power <br /> � requirea. FZM-1(A) Interface Module <br /> • High noise(EMF/RFI)immunity. • Supporis compatible two-wire smoke detectors. <br /> • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power <br /> • Direct-dial entry of address: 01 —159 on FlashScan loops; source. <br /> 01 —99 on CLIP loops. • High noise(EMF/RFI)immunity. <br /> • SEMS screws with clamping plates for ease of wiring. <br /> 3 �q 15 0 � ADDRESS o � • Direct-dial entry of address:01 —159 on FlashScan loops, <br /> � �3 � 2 � z 01 —99 on CLIP loops. <br /> 3 1z ((\� 3 LOOP 3 • LED flashes during normal operation;this is a programma- <br /> 11 ��O 4 O, 4 ble option. <br /> � 10 5 � 5 • LED latches steady to indicate alarm on command from <br /> � 9 $ � 6 9 g 7 6 contro)panel. <br /> TENS ONES The FZM-1(A) Interface Module is intended for use in intelli- <br /> ' � gent, addressable systems, where the individual address of <br /> each module is selected using built-in rotary switches. This <br /> � � Y module allows intelligent panels to interface and monitor two- <br /> wire conventional smoke detectors. It transmits the status(nor- <br /> � —wi W V mal,open,or alarm)of one full zone of conventional detectors <br /> � � � m back to the controi panel. All two-wire detectors being moni- <br /> tored must be UL compatible with the modufe. The FZM-1(A) <br /> can be used to replace MMX-2(A) modules in existing sys- <br /> tems. <br /> FZM-1(A) APPLICATIONS <br /> The FMM-101(A) Mini Monitor Module can be installed in a Use the FZM-1(A)to monitor a zone of two-wire smoke detec- <br /> single-gang junction direcUy behind the monitored unit. Its tors.The monitored circuit may be wired as an NFPA Style B <br /> small size and light weight allow it to be installed without rigid (Class B)or Style D(Class A)Initiating Device Circuit.A 3.9 K <br /> mounting. The FMM-101(A) is intended for use in intelligent, ohm End,of-Line Resistor(provided)terminates the end of the <br /> two-wire systems where the individual address of each module Style B or D (class B or A) circuit (maximum IDC loop resis- <br /> is se�ected using rotary switches. It provides a two-wire initiat- tance is 25 ohms). Install ELR across terminals 8 and 9 for <br /> ing device circuit for normally-open-contact fire alarm and Style D application. � <br /> security devices. The FMM-101(A) can be used to replace <br /> MMX-101(A)modules in existing systems. FZM-1(A)OPERATION <br /> FMM-]Ol A APPL/CATIONS Each FZM-1(A) uses one of the available module addresses <br /> � � on an SLC loop. It responds to regular polls from the control <br /> Use to monitor a single device or a zone of four-wire smoke panel and reports its type and the status(open/normal/short) <br /> detectors,manual fire alarm pull stations,waterflow devices,or of its Initiating Device Circuit (IDC) A flashing LED indicates <br /> other normaliy-open dry-contact devices. May aiso be used to that the module is in communication with the control panel. <br /> monitor normally-open supervisory devices with special super- The LED latches steady on alarm (subject to current limita- <br /> visory indication at the control panel. Monitored circuiUdevice tions on the loop). <br /> is wired as an NFPA Style B(Ciass B) Initiating Device Circuit. <br /> A 47K ohm End-of-Line Resistor(provided)terminates the cir- FZM-1(A)SPEClFICATIONS <br /> cuit. Nominal operating voltage: 15 to 32 VDC. <br /> FMM-101(A)OPERATION Maximum current draw:5.1 mA(LED on) <br /> Each FMM-101(A) uses one of the available module Maximum IDC wir(ng resistance:25 ohms. <br /> addresses on an SLC loop. It responds to regular polls from Average operating current: 300 NA, 1 communication and 1 <br /> the control panel and reports its type and the status(open/nor- LED flash every 5 seconds,3.9k eol. <br /> mai/short)of its Initiating Device Circuit(IDC). <br /> EOL resistance:3.9K ohms. <br /> FMM-101(A) SPEClFICATIONS External supply voltage (between Terminals T3 and T4): <br /> Nominal operating voltage. 15 to 32 VDC. DC voltage: 24 volts power limited. Ripple voltage. 0.1 Vrms <br /> Average operating current: 350 NA, 1 communication every maximum.Current:90 mA per module maximum. <br /> 5 seconds, 47k EOL; 600 NA Max. (Communicating, IDC Temperature range:32°F to 120°F(0'C to 49°C). <br /> Shorted). Humidity range: 10%to 93%noncondensing. <br /> Maximum IDC wiring resistance:40 ohms. Dimenslons: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x <br /> Maximum IDC Voltage:11 Volts. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x <br /> Maximum IDC Current:400 NA. 2.125"(5.398 cm)deep box. <br /> EOL resistance:47K ohms. <br /> Temperature range:32°F to 120°F(0°C to 49°C). <br /> Humidity range: 10%to 93%noncondensing. <br /> Page 2 of 4—DN-6720:C•10/06/2010 <br />
The URL can be used to link to this page
Your browser does not support the video tag.