DN-6724:63 <br /> u.s :�.x <br /> � FCM-1 (A) &�;FRM�=1"(A�� N OT1 F 1 E R� <br /> .��..��_ ; .�� �J <br /> Series <br /> � Control and Relay Modules by Honeywell <br /> � <br /> General <br /> FCM-1(A)Control Module: The FCM-1(A)Addressable Con- <br /> trol Module provides Notifier intelligent fire alarm control pan- '���a e '' ,�� <br /> els a circuit for Notification Appliances (horns, strobes, "�"' �; ' !�q <br /> speakers,etc.).Addressability allows the FCM-1(A)to be acti- '�_ <br /> vated, either manually or through panel programming, on a �, ;,. <br /> select(zone or area of coverage)basis. -;,�.,, •� ;. <br /> FRM-1(A)Relay Module: The FRM-1(A) Addressable Relay ""�`"""�'' ��'•..�.�! <br /> Module provides the system with a dry-contact output for acti- : ,,,�,,,�,,,i,, + „ ���r� <br /> vating a variety of auxiliary devices, such as fans, dampers, 4 <br /> control equipment,etc.Addressability allows the dry contact to "�!" `"""� �`r� <br /> ,,,,,»�7�«�:.�."., <br /> be activated, either manually or through panel programming, +.��` ,,,,,,�;,,,�,„,.,r„„„ � <br /> uMUkvW4�4MitP <br /> on a select basis. �,,, <br /> FlashScan�(U.S. Patent 5,539,389) is a communication pro- M„:: p <br /> tocol developed by NOTIFIER Engineering that greatly ��� �� <br /> enhances the speed of communication between analog intelli- „ <br /> gent devices. Intelligent devices communicate in a grouped ; <br /> fashion. If one of the devices within the group has new infor- , ' Y ���� I��I i� � ii+ f' � '''(� s <br /> mation,the panel CPU stops the group poll and concentrates --� < � <br /> on single points.The net effect is response speed greater than , <br /> five times that of other designs. FCM-1(A) <br /> Features <br /> • Built-in type identification automatically identifies these ' The FCM-1(A)is configured for a single Ciass B(Style Y)or <br /> devices to the control panel. Class A(Style Z)Notification Appliance Circuit. <br /> • Internal circuitry and relay powered directly by two-wire • The FRM-1(A) provides two Fornn-C dry contacts that <br /> SLC loop.The FCM-1(A)module requires power(for horns, ' switch together <br /> strobes,etc.),or audio(for speakers)._ <br /> • Integral LED "blinks" green each time a communication is Operation <br /> received from the control panel and turns on in steady red Each FCM-1(A)or FRM-1(A)uses one of 159 possible module <br /> when activated. addresses on a SLC loop (99 on,CLIP loops). It responds to <br /> • LED blink may be deselected globally(affects all devices). regular polls from the control panel and reports its type and <br /> • High noise immunity(EMF/RFI). status, including the open/normal/short status of its Notifica- <br /> • The FCM-1(A) may be used to switch 24-volt NAC power, tion Appliance Circuit (NAC). The LED blinks with each poll <br /> received. On command, it activates its internal relay. The <br /> audio(up to 70.7 Vrms). FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) <br /> • Wide viewing angle of LED. notification or control circuits. <br /> • SEMS screws with clamping plates for wiring ease. Upon code command from the panel, the FCM-1(A) will dis- <br /> • Direct-dial entry of address 01— 159 for FlashScan loops, connect the supervision and connect the external power sup- <br /> 01 —99 for CI.IP mode loops. ply in the proper polarity across the load device. The <br /> • Speaker, and audibleNisual applications may be wired for disconnection of the supervision provides a positive indication <br /> Class B or A(Style Y or Z). to the panel that the control relay actually turned ON. The <br /> external power supply is always relay isolated from the com- <br /> Applications munication loop so that a trouble condition on the external <br /> power supply will never interfere with the rest of the system. <br /> The FCM-1(A)is used to switch 24 VDC audible/visual power, Rotary switches set a unique address for each module. The <br /> high-level audio (speakers). The FRM-1(A) may be pro- address may be set before or after mounting. The built-in <br /> grammed to operate dry contacts for applications such as door TYPE CODE (not settable)will identity the module to the con- <br /> hoiders or Air Handling Unit shutdown, and to reset four-wire troi panel,so as to differentiate between a module and a sen- <br /> smoke detector power. sor address. <br /> NOTE:Refer to the SLC Manual(PN 51253)for details regarding <br /> re/easing applications with the FCM-1(A). Refer to the FCM-I-REL Specifications for FCM-��/�� <br /> datasheet(DN-60390)for new F1ashScar�re/easing applications. <br /> Normal operating voltage: 15 to 32 VDC. <br /> Construction Maximum current draw: 6.5 mA(LE[)on). <br /> • The face plate is made of off-white heat-resistant plastic. Average operating current: 350 NA direct poll,375 NA group <br /> • Controls include 1wo rotary switches for direct-dial entry of poll with LED flashing, 485 NA Max. (LED flashing, NAC <br /> address(01-159) shorted.) <br /> DN-6724:83•2/17/2011—Page 1 of 2 <br />