My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13001
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2013 10:29:18 AM
Creation date
2/14/2013 10:26:53 AM
Metadata
Fields
Template:
Building Department
Company Name
MERCHANTS STATION LLC
Building Department - Doc Type
Permit
Permit #
12-13001
Building Department - Name
MERCHANTS STATION LLC
Address
7339 7343 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Minimum Battery Size:7 AH. MS-10UD-7E: Same as above with 240 VAC FLPS-7 <br /> Initiating Device Circuits —TB4 (and TB 6 on MS-10UD-7 IpDACT, IPDACT2/2UD Internet Monitoring Module: <br /> o��Y)� Mounts in bottom of enclosure with optional mounting kit (PN <br /> • Alarm Zones 1 -5 on TB 4(MS-5UD-3 and MS-10UD-7). IPBRKT) Connects to primary and secondary DACT tele- <br /> ' ' Alarm Zones 6- 10 on TB6(MS-10UD-7 only) phone output ports for internet communications over customer <br /> � provided ethernet internet connection. Requires compatible <br /> • Supervised and power-limited circuitry. Teldat Visoralarm Central Station Receiver Can use DHCP or <br /> • Operation:All zones Style B(Class B) static IP (See data sheet DF-60407 for more information.) <br /> • Normal Operating Voltage: Nominal 20 VDC IPBRKT: Mounting kit for IPDACT in common enclosure <br /> • Alarm Current: 15 mA minimum. IPSPLT: Y Adaptor option to allow connection of both panel <br /> • Short Circuit Current:40 mA max. dialer outputs to one cable input to IPDACT(sold separately) <br /> • Maximum Loop Resistance 100 ohms. OPTIONAL MODULES <br /> • End-of-Line Resistor• 4 7K ohm, 1/2 watt (P/N 71252 UL- CAC-5X:Optional(Class A)Converter Module.Converts Style <br /> listed) B (Class B) Initiating Device Circuits xo Style D (Class A); and <br /> • Standby Current:2 mA. Style Y (Class B) Notification Appliance Circuits to Style Z <br /> Refer to the Fire•Lite Device Compatibility Documentfor listed (Class A) Connects to J2 on the MS-5UD-3 and MS-10UD- <br /> compatible devices. 7(E)main circuit board and to J7 on the MS-10UD-7(E). <br /> Notification Appliance Circuits — TB5 (and TB 7 on MS- NOTE: Two C/ass A Converter Modules are required for the ten- <br /> 10UD-7 only): zone panel. <br /> • Four NACs 4XTMF: Transmitter module. Provides a supervised output for <br /> • Operation• Sryle Y(Class B) local energy municipal box transmitter and alarm and trouble <br /> reverse polarity. Includes a disable switch and disable trouble <br /> • Special Application power LED A module jumper option allows the reverse polarity circuit <br /> • Supervised and power-limited circuitry to open with a system trouble condition if no alarm conditions <br /> • Normal Operating Voltage Nominal 24 VDC exists. Mounts to the main circuit board connectors J4 and J5 <br /> • Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A COMPATIBLEANNUNCIATORS <br /> maximum per NAC; 7 0 A for MS-10UD-7(E), 3.0 A maxi- <br /> mum per NAC ANN-80: Remote LCD Annunciator Mimics the information <br /> • End-of-Line Resistor:4 7K ohm, 1/2 watt(Part#71252) displayed on the FACP's LCD Red. (For white, order• ANN- <br /> 80-W) <br /> • Max.Wiring Voltage Drop•2 VDC ANN-LED: LED Annunciator with three LEDs for each zone: <br /> Refer to the Fire•Lite Device Compatibility Documentfor com- Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) <br /> patible listed devices. dress panel. Red. (For white,order ANN-LED-W.) <br /> Form C Relays—TB8: ANN-RLED: LED Annunciator with three alarm (red) indica- <br /> • Relay 1 (factory default programmed as Alarm Relay) tors for up to 30 input zones or addressable points. (Red. For <br /> • Relay 2 (factory default programmed as fail-safe Trouble white,order ANN-LED-W.)(See DF-60241) <br /> Relay) ANN-RLY: Relay module. Mounts inside the cabinet. Provides <br /> • Relay 3(factory default programmed as Supervisory Relay) ten Form C relays. <br /> Special Application Resettable Power—T69: ANN-S/PG:SeriaUparallel printer gateway. Provides a connec- <br /> • Jumper selectable by JP31 for resettable or nonresettable tion for a serial or parallel printer <br /> power ANN-1/O: Driver module. Provides connections to a user-sup- <br /> • Operating voltage:24 VDC nominal. plied graphic annunciator <br /> • Maximum available current: 500 mA- appropriate for pow- ACCESSOR/ES <br /> ering four-wire smoke detectors. DP-51050: Optional dress panel. Restricts access to the sys- <br /> • Power-limited circuit. tem wiring while allowing access to the membrane switch <br /> Refer to the Fire•Lite Device Compatibility Document for listed panel. <br /> compatible devices. BB-26: Battery backbox, holds up to two 25 AH batteries and <br /> Remote Sync Output-TB2: Remote power supply synchro- CHG-75 <br /> nization output,only required for the MS-5UD-3.24 VDC nom- gB-55: Battery backbox, holds up to two 25 AH batteries. <br /> inal special application power Maximum current is 40 mA. <br /> End-of-Line Resistor• 4 7K ohm Supervised and power-lim- TR-CE:Optional trim-ring for semi-flush mounted cabinets. <br /> ited circuit. PRN-6F: UL listed printer <br /> Product Line Information <br /> MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel <br /> (includes backbox, FLPS-3 power supply, technical manual, <br /> and a frame & post operating instruction sheet) 120 VAC <br /> operation <br /> MS-5UD-3E: Same as MS-5UD-3 except for 240 VAC opera- <br /> tion. <br /> MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel <br /> (includes backbox, FLPS-7 power supply, technical manual, <br /> and a frame&post operating instruction sheet) <br /> DF-52416:D•07/26/2010—Page 3 of 4 <br />