<br /> 6.6.4 For tile roof installations.
<br /> Installation is governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition.
<br /> Use is limited to System 1, Option 4, Section 3.02D in place of the"No. 30"felt. The"starter
<br /> strip" and "full-width-sheet" referenced therein shall be proportionate to the width of the
<br /> i ;�t: . ..t- �..tb':.,TIO?'' p��IVT`" pro���r_ , . . ... �... �� . .'��..i,__i iQp; �� _ ,� ., , ._ .,.. .
<br /> - � 5 5 -For non-tile roof;-�st�"�`��^5; _ ,.� , ,
<br /> 6.6.5.1 Standard Installation with Single Layer; roof slope > 4:12
<br /> Starting at the eave, fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the
<br /> field of the roll 12-inch o.c. in two, equaliy spaced, staggered center rows.
<br /> Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum
<br /> 6-inch end-laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced,
<br /> staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart.
<br /> 6.6.5.2 Standard Installation with Double Layer; 2:12 < roof slope < 4:12
<br /> Starting at the eave, fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the
<br /> field of the roll 12-inch o.c. in two, equally spaced, staggered center rows.
<br /> Continue upslope in a similar manner, with minimum 22.5-inch side-laps and minimum 6-
<br /> inch end-laps. Fasten 6-inch o.c. along the low edge and end laps and 12-inch o.c. in two,
<br /> equally spaced, staggered center rows in the field. Ensure all end laps are staggered at least
<br /> 3-feet apart.
<br /> 6.7 StormSafe'"' Anchor Sheet:
<br /> 6 7 1 StormSafe"" Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply
<br /> underlayment systems.
<br /> 6 7.2 Fasteners shall be 1-inch diameter plastic- or steel-capped corrosion resistant nails;
<br /> corrosion-resistant nails & 1-5/8-inch tin-caps; or Drill-Tec screws and plates.
<br /> 6.7.3 For tile roof installations:
<br /> Installation is governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition.
<br /> Use is limited to System 1, Option 6, Section 3.02F, System 2, Option 5, Section 3.02E,
<br /> System 4A, Option 5, Section 3.02E or System 46, Option 4, Section 3.02D in place of the
<br /> "No. 30"felt and as a base-layer beneath UnderRoof�"' 2. The attachment requirements shall
<br /> be proportionate to the width of the StormSafe'"' product.
<br /> 6.7.4 For non-tile roof installations:
<br /> Starting at the eave, fasten the eave edge and 6-inch wide end-laps 6-inch o.c. Fasten in the
<br /> field uf the roll 12-inch o c. in two, equally spaced, staggered center rows.
<br /> Continue upslope in a similar manner, maintaining minimum 3-inch side-laps and minimum
<br /> 6-inch end-laps. Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced,
<br /> staggered center rows in the field. Ensure all end laps are staggered at least 3-feet apart.
<br /> One the same day, install LibertyTM SBS Self-Adhering Base/Ply; Ruberoid� SA Base/Ply;
<br /> Storm�uard�; UnderRoofT"^ 2; UnderRoof'^' HT; Weather Watch� or Weather Watch � XT
<br /> over the StormSafeT'" Anchor Sheet.
<br /> 6.8 RoofProT"' SBS-lNodified All-Pur�ose Underlavment and Shinqle-Mate'"' Roof Deck
<br /> Protection•
<br /> 6.8.1 Install RoofPro'"' and Shingle-Matr"^ in compliance with manufacturer's published installation
<br /> instructions and the requirements for ASTM D226, Type I and II unde�rlayments in FBC
<br /> Sections 1507 for the type of prepared roof covering to be installed. A double layer is
<br /> required for 2.12 < roof slope < 4•12. No hammer tacks or staples are permitted.
<br /> Exterior Research and Design, LLC. Evaluation Report 01506.04.08-R6
<br /> Certificate of Authorization#9503 FL10626-R6
<br /> Revision 6: 12/13/2011
<br /> Page 7 of 11