<br /> I Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
<br /> � i Advanced Air Solutions Inc. Kline Residence
<br /> , Tampa,FL_33634_
<br /> - --- -
<br /> - - — - - - - - --- ----- --�-e 5
<br /> -- -- - - - -- -- ---- ---— -
<br /> TotalBuildin Summa Loads
<br /> I ---
<br /> - �' --- rY
<br /> � I Component Area Sen Lat Sen Total
<br /> � Description Quan Loss Gain Gain Gain
<br /> 1A-cm-o: Glazing-Single pane, operable window, clear, 144 5 0 0 8,867 8,867 '
<br /> metal frame no break, u-value 1.27, SHGC 0 75
<br /> � 11A. Door-Wood-Hollow Core 42 0 0 612 612 �
<br /> 13A-2ocb� Wall-Block, board insulation only, R-2 board 1237.5 0 0 5,822 5,822
<br /> ' insulation, open core, brick finish
<br /> � 166-13. Roof/Ceiling-Under Attic with Insulation on Attic 1434 4 0 q 5,522 5,522 I
<br /> Floor(also use for Knee Walls and Partition Ceilings),
<br /> Vented Attic, No Radiant Barrier, Dark Asphalt
<br /> Shingles or Dark Metal, Tar and Gravel or
<br /> Membrane, R-13 insulation
<br /> FLOOR ON SLAB: Floor-Over open crawl space or 1434 4 0 Q 710 710 �
<br /> garage, Custom, FLOOR ON THE SLAB
<br /> ' Subtotals for structure: 0 0 21,533 21,533
<br /> � People: 4 800 920 1,720 ,
<br /> Equipment: 0 1,200 1,200
<br /> Lighting 200 682 682 I,
<br /> Ductwork: 0 620 2,918 3,538
<br /> Infiltration. Winter CFM: 0, Summer CFM• 44 0 1,387 967 2,354
<br /> Ventilation Winter CFM 0, Summer CFM 0 0 0 0 0 ,
<br /> Total Building Load Totals. 0 2,807 28,220 31,027 I
<br /> i I Check Figures � I
<br /> Total Building Supply CFM: 1,284 CFM Per Square ft.. 0.895 *
<br /> , Square ft. of Room Area. 1,434 Square ft. Per Ton. 555
<br /> Volume(ft3)of Cond. Space: (clg.) 11,475
<br /> " Based on area of rooms being heated or cooled (whichever governs system) rather than entire floor area. '
<br /> - --— -
<br /> -
<br /> - - - -
<br /> -- -- -- -- --- - -- ---- - - - - -- ---�
<br /> � Building Loads
<br /> Total Sensible Gain: 28,220 Btuh 91 %
<br /> Total Latent Gain. 2,807 Btuh 9 % '
<br /> Total Cooling Required Including Ventilation Air: 31,027 Btuh 2.59 Tons(Based On Sensible+ Latent)
<br /> � - - - - - - - -- - -- - - -- - --
<br /> I ! Notes --- -- - --� ,
<br /> � Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> I Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D '
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at �
<br /> I your design conditions. i
<br /> � I
<br /> I
<br /> �
<br /> i
<br /> i
<br /> I
<br /> I
<br /> , I
<br /> I j
<br /> ;
<br /> i
<br /> I
<br /> I
<br /> C.1UserslJao n - - - - - - - I
<br /> s \Desktop\HEATHER KLINE.rhv Thursday,April 26, 2012, 3 45 PM