- - -- - - -- - - - - - - - - - - --- - <br /> I Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> � i Advanced Air Solutions Inc. Kline Residence <br /> , Tampa,FL_33634_ <br /> - --- - <br /> - - — - - - - - --- ----- --�-e 5 <br /> -- -- - - - -- -- ---- ---— - <br /> TotalBuildin Summa Loads <br /> I --- <br /> - �' --- rY <br /> � I Component Area Sen Lat Sen Total <br /> � Description Quan Loss Gain Gain Gain <br /> 1A-cm-o: Glazing-Single pane, operable window, clear, 144 5 0 0 8,867 8,867 ' <br /> metal frame no break, u-value 1.27, SHGC 0 75 <br /> � 11A. Door-Wood-Hollow Core 42 0 0 612 612 � <br /> 13A-2ocb� Wall-Block, board insulation only, R-2 board 1237.5 0 0 5,822 5,822 <br /> ' insulation, open core, brick finish <br /> � 166-13. Roof/Ceiling-Under Attic with Insulation on Attic 1434 4 0 q 5,522 5,522 I <br /> Floor(also use for Knee Walls and Partition Ceilings), <br /> Vented Attic, No Radiant Barrier, Dark Asphalt <br /> Shingles or Dark Metal, Tar and Gravel or <br /> Membrane, R-13 insulation <br /> FLOOR ON SLAB: Floor-Over open crawl space or 1434 4 0 Q 710 710 � <br /> garage, Custom, FLOOR ON THE SLAB <br /> ' Subtotals for structure: 0 0 21,533 21,533 <br /> � People: 4 800 920 1,720 , <br /> Equipment: 0 1,200 1,200 <br /> Lighting 200 682 682 I, <br /> Ductwork: 0 620 2,918 3,538 <br /> Infiltration. Winter CFM: 0, Summer CFM• 44 0 1,387 967 2,354 <br /> Ventilation Winter CFM 0, Summer CFM 0 0 0 0 0 , <br /> Total Building Load Totals. 0 2,807 28,220 31,027 I <br /> i I Check Figures � I <br /> Total Building Supply CFM: 1,284 CFM Per Square ft.. 0.895 * <br /> , Square ft. of Room Area. 1,434 Square ft. Per Ton. 555 <br /> Volume(ft3)of Cond. Space: (clg.) 11,475 <br /> " Based on area of rooms being heated or cooled (whichever governs system) rather than entire floor area. ' <br /> - --— - <br /> - <br /> - - - - <br /> -- -- -- -- --- - -- ---- - - - - -- ---� <br /> � Building Loads <br /> Total Sensible Gain: 28,220 Btuh 91 % <br /> Total Latent Gain. 2,807 Btuh 9 % ' <br /> Total Cooling Required Including Ventilation Air: 31,027 Btuh 2.59 Tons(Based On Sensible+ Latent) <br /> � - - - - - - - -- - -- - - -- - -- <br /> I ! Notes --- -- - --� , <br /> � Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> I Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D ' <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at � <br /> I your design conditions. i <br /> � I <br /> I <br /> � <br /> i <br /> i <br /> I <br /> I <br /> , I <br /> I j <br /> ; <br /> i <br /> I <br /> I <br /> C.1UserslJao n - - - - - - - I <br /> s \Desktop\HEATHER KLINE.rhv Thursday,April 26, 2012, 3 45 PM <br />