Rhvac-Residential 8 Light Commercial HVAC Loads Elite Software Development,Inc.
<br /> �Advanced Air Solutions Inc. Kline Residence
<br /> I Tampa FL 33634___ �
<br /> —
<br /> - ---- -- - - - - -- - age 6
<br /> - - -- -- - --
<br /> -- -- -- --
<br /> - - - - -- - — ---I
<br /> ; S stem 1 S stem 1 Summa Loads ,
<br /> j -�—- - --Y-- -- -- -- rY -- -
<br /> IComponent Area Sen �at Sen Total i
<br /> , ' Description Quan Loss Gain Gain Gain '
<br /> 1A-cm-o� Glazing-Single pane, operable window, clear, 144 5 0 0 8,867 8,867
<br /> metal frame no break, u-value 1.27, SHGC 0 75
<br /> � 11A. Door-Wood -Hollow Core 42 0 0 612 612 I
<br /> I 13A-2ocb Wall-Block, board insulation onfy, R-2 board 1237.5 0 0 5,822 5,822 '
<br /> insulation, open core, brick finish
<br /> i 166-13: Roof/Ceiling-Under Attic with Insulation on Attic 1434 4 0 0 5,522 5,522
<br /> Floor(also use for Knee Walls and Partition Ceilings),
<br /> Vented Attic, No Radiant Barrier, Dark Asphalt ;
<br /> Shingles or Dark Metal, Tar and Gravel or '
<br /> Membrane, R-13 insulation II
<br /> ',I FLOOR ON SLAB Floor-Over open crawl space or 1434 4 0 Q 710 710 I
<br /> , garage, Custom, FLOOR ON THE SLAB
<br /> Subtotals for structure: 0 � 21,533 21,533
<br /> People: 4 800 920 1,720
<br /> ! Equipment: � 1,200 1,200
<br /> �� Lighting. 200 682 682
<br /> Ductwork: 0 620 2,918 3,538 I
<br /> Infiltration. Winter CFM. 0, Summer CFM: 44 0 1,387 967 2,354 �
<br /> Ventilation: Winter CFM: 0, Summer CFM 0 0 0 0 0
<br /> System 1 System 1 Load Totals. 0 2,807 28,220 31,027
<br /> I �Check Figures
<br /> Supply CFM: 1,284 CFM Per Square ft.• p g95 • I
<br /> Square ft. of Room Area. 1,434 Square ft. Per Ton. 555
<br /> Volume(ft')of Cond. Space: (clg.) 11,475
<br /> ' * Based on area of rooms being heated or cooled (whichever govems system) rather than entire floor area. I 'I
<br /> - ---
<br /> -- --
<br /> - - - -
<br /> ;System Loads - --
<br /> --- — -- -- -- -
<br /> -- --- ---
<br /> Total Sensible Gain. 28,220 Btuh 91 % I�
<br /> � Total Latent Gain. 2,807 Btuh 9 % �
<br /> Total Cooling Required Including Ventilation Air 31,027 Btuh 2.59 Tons (Based On Sensible+ Latent) I
<br /> - -- - —
<br /> - -
<br /> , otes — -- - - ---- - -- - -- ---�
<br /> , Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D
<br /> I All computed results are estimates as building use and weather may vary
<br /> � Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's perFormance data at
<br /> , your design conditions.