Laserfiche WebLink
- ' - - <br /> i � Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. � <br /> Advanced Air Solutions Inc. Kline Residence i <br /> I ,_Tampa FL 33634_ <br /> �! j Sy_stem 1L_Zone 1_Summary_Loads (Avera�e Load Procedure for_Rooms) __ P�e7I � <br /> i Component Area Sen Lat Sen Total f <br /> ' Description Quan Loss Gain Gain Gain <br /> I 1A-cm-o. Glazing-Single pane, operable window, clear, 144 5 0 0 8,867 8,867 ', <br /> metal frame no break, u-value 1.27, SHGC 0 75 <br /> 11A: Door-Wood-Hollow Core 42 0 0 612 612 <br /> 13A-2ocb� Wall-Block, board insulation only, R-2 board 1237.5 0 �� 5,g22 5 g22 � <br /> insulation, open core, brick finish <br /> I 166-13� Roof/Ceiling-Under Attic with Insulation on Attic 1434 4 0 0 5,522 5,522 <br /> Floor(also use for Knee Walls and Partition Ceilings), <br /> Vented Attic, No Radiant Barrier, Dark Asphalt i <br /> Shingles or Dark Metal, Tar and Gravel or i <br /> Membrane, R-13 insulation � <br /> I!, FLOOR ON SLAB. Floor-Over open crawl space or 1434.4 0 0 710 710 <br /> garage, Custom, FLOOR ON THE SLAB <br /> Subtotals for structure. 0 0 21,533 21,533 <br /> IPeople 4 80Q 920 1,720 <br /> Equipment: 0 1,200 1,200 <br /> Lighting. 200 682 682 <br /> Ductwork: 0 0 2,918 2,918 � <br /> Infiltration: Winter CFM: 0, Summer CFM:44 0 1,387 967 2,354 <br /> System 1, Zone 1 Load Totals 0 2,187 28,220 30,407 I <br /> � � Check Figures � <br /> , Supply CFM� 1,284 CFM Per Square ft.. p 895 * I I� <br /> � Square ft. of Room Area. 1,434 Square ft. Per Ton: 5 6 6 <br /> Volume(ft') of Cond. Space: (clg.) 11,475 <br /> I ` Based on area of rooms being heated or cooled(whichever governs system) rather than entire floor area. <br /> - - <br /> ' (Zone Loads - - - — <br /> - --- -- -- - <br /> - - -- --- , <br /> Total Sensible Gain — —� � <br /> 28,220 Btuh 93 % �i <br /> I Total Latent Gain. 2,187 Btuh 7 % ' <br /> Total Cooling Required. 30,407 Btuh 2.53 Tons(Based On Sensible+ Latent) <br /> Ij �i Notes - - <br /> - -- -- - <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. —� <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. ' <br /> ' All computed results are estimates as building use and weather may vary. � <br /> � Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at � <br /> your design conditions. <br /> � , <br /> i <br /> I � <br /> ,I � <br /> � <br /> � <br /> Thursday,April 26, 2012, 3.45 PM 'I <br /> - - - - - - _ <br /> C.\UserslJaosnlDesktoplHEATHER KLINE rhv <br />