My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13441
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13441
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2013 10:39:35 AM
Creation date
7/18/2013 10:39:33 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR COMMONS
Building Department - Doc Type
Permit
Permit #
12-13441
Building Department - Name
SF ZEPHYR COMMONS LP
Address
7920 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ANN-BUS DEVICE ADDRESSING Atter calculating the totai worst case current draw, the following <br /> Each ANN-BUS device requires a unique address(ID Number) �ble specifies the maximum distance the modules can be <br /> in order to communicate with the FACP A maximum of 8 devices located from the FACP on a single wire run. The table ensures <br /> can be connected to the FACP ANN-BUS communication circuit. 6.0 volts of line dr�p maximum. in general,the wire length is lim- <br /> See the FACP manual for more information. ited by resistance, but for heavier wire gauges, capacitance is <br /> the limiting factor <br /> WIRE REQUIREMENTS:COMMUNICATIDIVS CIRCUlT These cases are marked in the chart with an asterisk(') Maxi- <br /> The ANN-80 connects to the FACP ANN-BUS communications mum length can never be more than 6,000 feet (1,800 m), <br /> circuit. To determine the type of wire and the maximum wiring regardiess of gauge used. See table below. <br /> distance that can be used with FACP ANN-BUS accessory mod- W�RE REQUIREMENTS:POWER CIRCUlT <br /> ules, it is necessary to calculate the total worst case current <br /> draw for all modules on a single 4-conductor bus.The total worst • 14 to 18 AWG (0 75-2.08 mm2) wire for 24 VDC power cir- <br /> case current draw is calculated by adding the individuai worst cuit is acceptable. Power wire distance limitation is set by 1.2 <br /> case currents for each module. volt ma�cimum line drop form source to end of circuit. <br /> NOTE: For tota/ worst case current draw on a single ANN-BUS • All connections are power-limited and supervised. <br /> refer to appropriate FACP manual. • A maximum of eight ANN-80 modules may be connected to <br /> this circuit. <br /> Communication Pair Wiring Distance: FACP to Last ANN-BUS Module <br /> Total Worst Case 2y Gauge 18 Gauge 16 Gauge 14 Gauge <br /> Current Draw(amps) <br /> 0 100 1,852 ft. 4,688 ft. '6,000 ft. `6,000 ft. <br /> 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. <br /> 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. <br /> 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. <br /> 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. <br /> 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. <br /> 0 700 265 ft. 670 ft. 1,066 ft. 1,687 ft. <br /> 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. <br /> 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. <br /> 1.000(max.) 185 ft. 469 ft. 746 ft. 1,181 ft. <br /> WIRlNG CONFIGURATlON ORDERING OPTIONS: <br /> The following figure iilustrates the wiring between the FACP and ANN-80:Red 80 character LCD Annunciator. <br /> ANN-BUS devices. ANN-60-W:White,80 character LCD Annunciator <br /> ANN-BUS and power ANN-SB80KIT R: Red surface mount backbox with angled <br /> wiring are supervised wedge. <br /> and power-limited. ANN-SBBOKIT W: White surtace mount backbox with angled <br /> � B A , wedge. <br /> re, <br /> � 3 2 1 <br /> ANN-BUS Device <br /> ' ' A O <br /> MS-9050UD TB3 <br /> 1 2 3 4 5 6 7 6 <br /> FACP Wiring to ANN-BUS Device <br /> FireLite�Aiarms is a registered trademark ot Honeywell International Inc. <br /> (�YL009 by Honeywell International inc.All rights reserved.Unauthorized use <br /> ot this document is strictly prohibited. <br /> '�O �oo� This document is not intended to be used for installation purposes. <br /> We try to keep our product information up-to-date and accurate. <br /> We cannot cover all specific applications or anticipate all requirements. <br /> 91i�I�IR 6 MIIfACI�lI�i All specifications are subject to change without notice. <br /> QlALITI' SISTENS MadeinmeU.S.A. <br /> For more information,contact Fire�Lite Alarms.Phone:(B00)627-3473,FAX.(877)699-4105. <br /> www.firelite.com <br /> Page 2 of 2—df-52417:c•0522/09 <br />
The URL can be used to link to this page
Your browser does not support the video tag.