My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13441
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13441
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2013 10:39:35 AM
Creation date
7/18/2013 10:39:33 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR COMMONS
Building Department - Doc Type
Permit
Permit #
12-13441
Building Department - Name
SF ZEPHYR COMMONS LP
Address
7920 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/ <br /> COOPER Notification <br /> POWERPATH�" NAC POWER SUPPLIES <br /> PS-EXP <br /> PS-6 PS-8 <br /> Description <br /> The Wheelock Series PS-6 and PS-8 are 24VDC, filtered and The PS-6 and PS-8 Power Supplies are UL Listed under UL <br /> regulated, supervised remote power supply/battery chargers are Standard 864, 9th Edition to be used with any 24 volt Listed <br /> used for supervision and expanded power driving capability of Fire Regulated notification appliances.They include the capability <br /> Alarm Notification Appliance Circuits. The PS-6 provides 6 amps of to synchronize Wheelock strobes and horns and to silence the <br /> power distributed across 4 outputs,while the PS-8 provides 8 Amps horn signal when horn/strobes are opereting on two wires. <br /> across 4 output. In addition the PS-8 provides additional room in <br /> the chassis for accessories like an Addressable Control Module, with <br /> mounting studs. Approvals <br /> The Power Supplies may be connected to any 12V or 24V (FWR or 'Approvals Include:UL Standard 864,1481,California State <br /> DQ Fire Alarm Control Panel (FACP) by using a Notifitation Appliance Fire Marshal(CSFM), Factory Mutual(FM) <br /> Circuit (NAC) or a"Dry Contact". Primary applications include NAC •Compliant with NFPA 72 <br /> expansion (supports ADA requirements) and auxiliary power to <br /> support system accessories.This unit provides filtered and regulated �nputs <br /> 24VDC, up to four (4) Class"B; two (2) Class "A", or two (2) Class •120VAC,50/60Hz,4.25 Amps(PS-6/8)and 532 Amps <br /> "B"and one (t) Class"A" Notification Appliance Circuits. With the (PS-8)Operating Power in Alarm <br /> optional plug-in PS-EXP module the unit supports (8) Class"B"or .240VAC,60Hz,2.42 Amps(PS-GE and 3.22 Amps(PS-8E)' <br /> (4) Class"A"Notification Appliance Circuits. Additionally, an auxiliary Operating Power in Alarm <br /> power output of 2.5 Amps (disconnected upon AC power loss or an .24VDC Battery Backup Connection <br /> alarm condition) or up to 0.240 A of constant power on the PS-8 and ,Two(2),12V or 24V NAC Initiating Circuits(8-33V at SmA) <br /> 0.075 A of constant power on the PS-6. FWR or DC <br /> The Wheelock Power Supplies can accommodate 7 or 12 AH batteries .Two(2)"Dry"Contact initiating Circuits <br /> inside its lockable chassis. Using an external battery cabinet it can .Accepts two(2)Class"A"or two(2)Class"B"circuit inputs <br /> charge up to 33 AH batteries (pending UL testing). Two FACP NAC ,guilt in battery charger for sealed lead acid or gel type <br /> circuits or two"Dry"contact initiating circuits can be connected to the batteries <br /> inputs.These inputs can then be directed to control supervision and <br /> power delivery to any combination of the four(4)outputs.Each output <br /> is rated at 3.0 Amps (Class"B") or (Class"A") and can be programmed <br /> to generate a steady or Code 3 Temporal Horn sound and a strobe Outputs <br /> output under alarm condition.Total load for the PS-6 and PS-8 NAC �NAC outputs are 24VDC,3.0 Amps each,power limited <br /> circuits must not exceed the power supplies rated output. •8 Amps on PS-8 and 6 Amps on the PS-6 total alarm current <br /> The Power Suppliesunder non-alarm condition provides independent <br /> supervision for Class "A" and Class °B" FACP NAC circuits. In the <br /> event of circuit trouble, the FACP will be notified via the POWERPATH <br /> steered input (IN1 or IN2). In addition there are two sets of trouble <br /> reporting terminals, one �sed for AC power loss reporting and the <br /> other for all troubles.The AC power loss reporting, on the common <br /> trouble terminals and on IN1 or IN2, can be delayed for either 30 <br /> seconds or 170 minutes.The AC power loss terminals will always <br /> report the trouble within 1 second after loss of AC power <br /> U� =�: FM <br /> APPROII� <br /> ...Features continued on next page <br />
The URL can be used to link to this page
Your browser does not support the video tag.