My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13441
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13441
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2013 10:39:35 AM
Creation date
7/18/2013 10:39:33 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR COMMONS
Building Department - Doc Type
Permit
Permit #
12-13441
Building Department - Name
SF ZEPHYR COMMONS LP
Address
7920 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•Capable of four(4),CIaSs"B"circuits <br /> � •Capable of two(2)Class"A"circuits <br /> •Capable of one(1)Class"A"circuit and two(2)Class"B"circuits <br /> •Capable of(8)Class"B"or four(4)Class"A"circuits with optional PS-EXP module <br /> •Temporal(Code 3),constant voltage output,Wheelock Sync output or True input to output follower mode <br /> •Built-in Wheelock synchronization mode that can be fed to any or all of the output circuits <br /> •Input and output can be synchronized with"IN>OUT SYNC"mode(DSM,2nd POWERPATH'""or FACP with <br /> synchronization protocol is required) <br /> -Audible silence capability <br /> •Filtered and electronically regufated output <br /> •2.5 Amp auxiliary power limited output with reset capability (Removed upon AC loss or alarm.Automatic reset 30 seconds after <br /> AC power returns or the alarm condition is over)or 0.075 Amps(PS-6)or 0.240 Amps(PS-8)of auxiliary power limited output <br /> which remains on during AC loss or an alarm condition when configured for 24 hour battery backup <br /> Supervision <br /> •Compatible with 12V or 24V(FWR or DQ FACP <br /> •Signaling appliance circuits are supervised and steered to either IN1 or IN2 <br /> •10K Ohm,t Watt(Wheelock Model#MPEOL)End of Line Resistor(EOLR)for supervision of all outputs <br /> •37 distinguishable trouble diagnostics <br /> •AC loss trouble reported over a separate set of contacts(delay of 1 second) <br /> •All troubles are reported over the common trouble contacts(AC loss can have a delay of 30 seconds or 170 minutes) <br /> •Automatic switchover to standby battery when AC fails <br /> •Thermal and short circuit protection with auto reset <br /> •Input and output status LED indicators <br /> •AC fail supervision <br /> •Battery presence and low battery supervision <br /> •Ground Fault Detection,with diagnostics to indicate which circuit fault is on <br /> •Latching LED's for NAC trouble annunciation and Diagnostic trouble LED's(latching can be disabled) <br /> Power <br /> •Not Battery Dependent <br /> •Automatic switch over to standby batteries when AC fails <br /> •Supports sealed lead acid or gel type batteries <br /> •Fused battery protection <br /> •Thermal and short circuit protection with auto reset <br /> •�upports both 7AH or 12AH batteries in the same cabinet <br />
The URL can be used to link to this page
Your browser does not support the video tag.