Laserfiche WebLink
��SimplEx LifeAlarm° Fire Alarm Controls <br /> U�, U�C, CSFM Listed,�FM Approved,� 4009 I DNetTM NAC Extender for Control from 4010, 4010ES, <br /> MEA (NYC)Acceptance" 4100ES/4100U IDNet Communications, or Conventional NACs <br /> � <br /> Provides additional notification appliance circuit � � <br /> (NAC) capacity with flexible operation modes and <br /> power-limited design Upto 8 NACs <br /> Four, Class B NACs are standard: � � <br /> • Rated 2 A each for conventional reverse polarity 4009 IDNet <br /> 24 VDC notification appliances and providing NAC E�ender � � <br /> multiple operation modes =���������_ <br /> • Can be selected to provide synchronization for <br /> Simplex visible notification strobe flashes "" Optional IDNet <br /> • Capable of controlling TrueAlert�non-addressable Channel Repeater <br /> �� <br /> notification appliances operating with SmartSyncTnz ��_______�� <br /> two-wire control mode** �' ��� `.� �•� - <br /> Input control options: ; ��� `. �� <br /> � 2-Wire IDNet � � <br /> IDNet addressable communications from a Simplex Communications o� �� `��� `�`� <br /> mode14010,4010ES,4100U,or 4100ES Fire Alarm • � � <br /> ,�,� � Fiber Optic IDNet �� <br /> Control Panel i Communications or �� <br /> • Or from one or two conventional 24 VDC NACs with � �� � NAC Control <br /> multiple output control options _�%; <br /> IDNet communications control benefits: �-�- ipNe�F�ber <br /> • Provides status monitoring and individual NAC control Optic Transmitter <br /> using a single address per 4009 IDNet NAC Extender <br /> • Supports IDNet"Device Level"earth fault location 4010(shown)or � <br /> WALKTESTT'" operation is available with either 4010ESl4100ESl4100U <br /> input choice Alarm Control Panel <br /> Internal 8 A ower su I /batte char @C: Fire Alarm Control Panel with <br /> p pp y rY g Conventional NACs <br /> • Charges internal batteries up to 12.7 Ah or up to 18 Al� <br /> batteries in external cabinet 4009 IDNet NAC Extender Connection Reference Drawing <br /> • Provides status monitoring of battery,input power,and . . . <br /> earth faults <br /> • Rated 8 A for"Special Application"appliances; ADA Compliance.Complying with the notification <br /> including Simplex 4901,4903,4904,and 4906 Series requirements ofADA(Americans with Disabilities Act) <br /> horns,strobes,horn/strobes,and speaker/strobes may require more notification appliance power than is <br /> Rated 6 A for"Regulated 24 DC"appliance power available within the fire alarm control panel.When <br /> � additional power is required,a Simplex 4009 IDNet NAC <br /> Optional 4009 IDNet NAC Extender modules: Extender can provide up to 8 A of NAC power with up to <br /> • IDNet Communications Repeater provides Class B or eight,supervised reverse polarity NACs. <br /> Class A output Location Flexibility.The 4009 IDNet NAC Extender <br /> • IDNet Communications Fiber Optic Receiver/Repeater, can be mounted close to a compatible dedicated host <br /> available as Class B or Class X panel or can be located remotely for convenient power <br /> • Four additional Class B NACs,rated 1.5 A for Special distribution. Multiple operation modes and multiple <br /> Application appliances, 1 A for Regulated 24 DC connection options further increase location flexibility <br /> appliance power Additional Information.For additional operation detail <br /> • Class A,Two Circuit Adapter Module and application information,refer to Installation <br /> UL Listed to Standard 864 Instructions 574-181 and field wiring diagram 842-068. <br /> . , <br /> ' ULC listed model is 4009-9202CA.This product has been approved by the California <br /> ��N@t C011lll'1U111Cat1011 flbG't'OptIC tfallSlllltt@CS: State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and <br /> • Fol'8ppIlCStiOnS t'eC]u1T'ing tlle ClatB lritegi'ity 3Va11Sble Safety Code.See CSFM Listing 7300-0026:214 for allowable values andlor conditions <br /> concerning material presented in this document.It is subject to re-examination,re�ision, <br /> Wltl1 f b0T Opt1C COri1IriUri1Cat10nS and possible cancellation.Accepted for use-City of New York Department of Buildings <br /> • AV311ab10 aS Class B Ol'C18SS X -MEA35-93E.Additional listings may be applicable;contact your local Simplex product <br /> supplier for the latest status.Listings and approvals under Simplex Time Recorder Co <br /> • MOUritS lri SY3riC11PCl S1X-glrig eleCtT1C31 bOX are the property of SimplexGrinnell LP,Westminster <br /> External battery cabinet for 18 Ah batteries "4100U requires revision 11 software or higherfor compatibility 4010 requires revision 2 <br /> software or higher for compatibility <br /> S4009-0002-9 <br />