. . . . . . . . . � . . . . <br /> NAC Input Selections.The 4009 IDNet NAC The TrueAlert Notification Appliance product line <br /> Extender can be selected to: includes addressable and non-addressable operation. <br /> • Track input NAC operation or to provide a locally Non-addressable models are available with 2-wire <br /> generated code,selectable per NAC input SmartSync operation or conventic+nal4-wire operation. <br /> The following details apply to use with the 4009 IDNet <br /> • If selected far local coding,NAC outputs can be either NAC Extender: <br /> Temporal Coded or 60 Beats/min March Time Coded, <br /> one code selection per extender(input NACs must be on • TrueAlert non-addressable madels with SmartSync <br /> continuous with Alarm) operation allow audible notification to be separately <br /> • Additionally,NAC outputs can be selected to provide controlled over the same wire pair that controls visible <br /> the Simplex strobe synchronization signal.This signal notification <br /> will synchronize the flashes of synchronized strobes but • 4009 IDNet NAC Extenders can be selected to provide <br /> will be ignored by free-run strobes and audible devices. SmartSync operation whether controlled by IDNet <br /> (Strobes are for operation by noncoded NACs.) communications or conventional NACs <br /> NAC input to NAC output control can be selected for • IDNet control allows output I�fACs to be individually <br /> standard and optional NACs per the following table: selected for conventional or SmartSync operation <br /> Conventional NAC Output Operation Options • With NAC input control,all output NACs are selected <br /> Input A B C for either conventional or SmartSync operation <br /> NAC 1 NACs 1 &2,5&6 NACs 1-4 NACs 1-8 . Refer to data sheet S4009-OOQ3 for TrueAlert <br /> NAC 2 NACs 3&4,7&8 NACs 5-8 None Addressable operation details; contact your local <br /> SmartSync NAC Output Operation Simplex product supplier for iurther information on <br /> Input NAC Control Function specific TrueAlert notification appliances <br /> NAC 1 Strobe Control All NAC outputs(1-8) <br /> NAC 2 Horn Control <br /> ■ _ • � • � • � • . • - ■ . • <br /> Up to eight(8)output NACs total;hardwire control can be <br /> selected to map NAC inputs to different combinations of <br /> NAC outputs depending on system requirements <br /> NAC 1 input <br /> (see Note 1) <br /> ---_------_ � Conventional NACs R <br /> � � -=_=���__ - - - - \� <br /> � � With hardwire control, <br /> o ""° ""' NAC outputs are� <br /> � a Output conventional or�ll <br /> ----- ----� - ' � NACs SmartSync operation <br /> - - �ma=��°a_�=€= <br /> � -=-__-----° / <br /> � 4009 IDNet NAC� - - <br /> i Extender i � � i <br /> Fire Alarm Control Panel i i ��� i <br /> i i SmartSync operation ___� <br /> with Conventional NACs i �______________________ <br /> i <br /> � Class A operation,either mode,requires <br /> NAC 2 input � 4009-9808 Dual Class A Adapter <br /> (optional,see Note 1) � <br /> i <br /> � To additional 4009 IDNet NAC Extenders(up to four(4), <br /> i <br /> �---------- 4009 IDNet NAC Extenders per NAC);see Note 2 <br /> Notes: <br /> 1 For separate audible and visible output NAC control,or SmartSync NAC output operation,two(2)input NACs are required. <br /> NAC 1 is"on-until-reseY'and NAC 2 is"on-until-silenced." <br /> 2.To synchronize strobe flash outputs for up to four(4)4009 IDNet NAC Extenders,use the synchronized strobe <br /> output from a Synchronized Flash Module(4905-9914 for Class B operation,4905-9922 for Class A operation)or, <br /> if available,from a NAC selected to provide synchronized strobe flash output. NOTE:DO NOT USE a NAC selected <br /> for SmartSync operation for this function. <br /> Refer to Installation Instrucfions 574-181 for additional information and application guidance <br /> 4 S4009-0002-9 <br />