Laserfiche WebLink
I , ' � . � � <br /> 120 VAC Input(4009-9201) 3A @ 102-132 VAC,60 Hz <br /> Input 240 VAC Input(4009-9301) 1 5A @ 204-264 VAC,50/60 Hz <br /> Ratings Hardwire Control from External Conventional reverse polarity operation <br /> NACs, input Requirements 5 mA maximum; 16 to 33 VDC <br /> Total Rating 8 A, Special Application appliances <br /> 6 A, Regulated 24 DC appliance power <br /> Standard NACs 2 A each, Special Application or Regulated 24 DC appliance power <br /> Optional NACs 1 5 A each, Special Application appliances <br /> (requires 4009-9807) 1 A each, Regulated 24 DC appliance power <br /> Special Application Simplex 4901,4903,4904,and 4906 Series non-addressable horns, strobes, <br /> Output Ratings and combination horn/strobes and speaker/strobes(contact your Simplex <br /> Appliances product representative for compatible appliances) <br /> Regulated 24 DC Power for other UL listed appliances, use associated external synchronization <br /> Appliances modules where required <br /> Strobe Operation Up to 33 strobes per NAC can be synchronized; output NACs configured for <br /> Simplex synchronized strobe operation are synchronized to each other <br /> Auxiliary Output 500 mA @ 24 VDC nominal <br /> Optional Modules Ratings <br /> Input Power 70 mA @ 24 VDC,system supplied <br /> IDNet Input, One Address Maximum distance from IDNet source is 2500 ft(762 m) <br /> IDNet Repeater Repeated IDNet output for up to 100 devices(total IDNet devices not to exceed <br /> Module 250 per channel) <br /> (4009-9809) IDNet Output Specifications Maximum distance to farthest device is 2500 ft(762 m) <br /> Total distance including"T-taps"is 10,000 ft(3048 m) <br /> Class A loop maximum distance is 2500 ft(762 m), no"T"taps <br /> Fiber Optic Receiver Modules <br /> 4009-9810, Class B, 65 mA @ 24 VDC,system supplied <br /> Input Current 4009-9811, Class X,80 mA @ 24 VDC,system supplied <br /> IDNet Output Specifications Same as those for Repeater Module(see above) <br /> Fiber Optic Transmission Distance 3000 ft(914 m)maximum <br /> General(LED status indicators are listed on page 7,dimensions and mounting details are on page 6) <br /> Operating Temperature 32°to 120°F(0°to 49°C) <br /> Operating Humidity Range 10%to 90%RH from 32° F to 104° F(0°C to 40°C) _ <br /> Wiring Connections" Terminal blocks for 18 AWG(stranded)to 12 AWG(solid) <br /> • - • • •- • <br /> Input Voltage 18 9-32 VDC from compatible listed fire alarm supply <br /> 4090-9105, Class B, 30 mA @ 24 VDC _ <br /> Input Current 4090-9107, Class X, 35 mA @ 24 VDC <br /> Multimode, graded index, 50/125Nm,62.5/125 Nm, 100/40 Nm, or 200 Nm <br /> Fiber Optic Connections and cable Type ST connectors <br /> requirements 4090-9105, Class B operation,two fiber cables required <br /> 4090-9107, Class X operation,four fiber cables required <br /> Module Size(with mounting bracket) 6-13/16"W x 3-3l4" H x 1-1/8"D(173 mm x 95 mm x 29 mm) <br /> Green LED flashing=transmit <br /> On-board Status Indicators Red LED flashing=receive <br /> Separate red LED on 4090-9107=Class X receive <br /> Communications Simplex IDNet <br /> Fiber Optic Transmission Distance 3000 ft(914 m)maximum <br /> Wiring Connections` Terminal blocks for 18 AWG(stranded)to 12 AWG(solid) <br /> Operating Humidity 10%to 90%RH from 32°to 104° F(0°to 40° C) _ <br /> Operating Temperature 32° F to 120° F(0°to 49°C) <br /> 'Metric wire equivalents� 18 AWG=0 82 mm2; 12 AWG=3.31 mm2 <br /> 5 S4009-0002-9 <br />