My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13462
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13462
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2013 11:32:29 AM
Creation date
7/22/2013 11:26:17 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
12-13462
Building Department - Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Address
7050 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� 1 • 1 • 1 • 1 � ► � •- • � • <br /> Surtace mount box: __� ° o 0 0 0 0 <br /> Simplex model 2975-9217 <br /> (ordered separately) <br /> Flush mount masonry box: o n �� o o O <br /> use 6-gang box, RACO#960,2-1/2"deep �� � � � ° ° o O <br /> (64 mm),or RACO#965,3-1l2"(89 mm) <br /> deep,or equal(supplied by others) � � <br /> 0 0 � � � ° O O <br /> Flush mount ganged boxes: � <br /> use 6-gang box, 1-1l2"(38 mm) � � <br /> minimum depth;six,RACO#400 O O <br /> or equal, (supplied by others) <br /> 0 0 0 0 <br /> 0 0 0 0 0 o IDNet fiber optic transmitter: <br /> 4090-9107,Shown,Class X(Style 7)output <br /> 4090-9105, Not shown,Class B(Style 4)output <br /> INSTALLATION NOTE: <br /> Fiber optic cable bend radius shouid be 2"(51 mm) <br /> minimum,or per Manufacturer's specification. <br /> 0 0 0 0 0 0 <br /> Six-gang blank cover plate Mulberry Metal <br /> Products 97156 or equal(by others) <br /> _ � . � � LED Status Indicators are provided for the following: <br /> Power-up Self-Diagnostics.Upon power-up,the • Each NAC(standard and optional)has a dedicated <br /> 4009 IDNet NAC Extender tests each module and yellow LED that: <br /> perfoims earth fault diagnostics.Trouble conditions are — During supervision provides a slow flash to indicate <br /> communicated to the host control panel and are also a short circuit condition and a fast flash to indicate <br /> displayed on diagnostic status LEDs in the 4009 IDNet an open circuit <br /> NAC Extender. When connected via lDNet — During an alarm,the LED follows the NAC output <br /> communications,detailed status information is available (on steady or flashing with coded output) <br /> at the host.When controlled with conventional NAC . Four, general status yellow LEDs provide nine <br /> inputs,common troubles are signaled by providing a <br /> polarized open circuit that disconnects the NAC wiring separate indications listed in priority of urgency.As a <br /> from its end-of-line resistor but still allows a reversed trouble is eliminated,any remaining trouble(s)will <br /> polarity alarm to be received. then be indicated until the 4009 IDNet NAC Extender <br /> is returned to normal operation. <br /> Door Mounted Reference Label.The 4009 IDNet <br /> NAC Extender has a detailed programming and • AC power status is indicated by a green LED that is <br /> diagnostic label inside the front door that provides a quick on when AC is normal.During low AC(brownout) <br /> reference for both installation and checkout. conditions or with no AC,the LED is off.Additional <br /> power and battery status is indicated by the general <br /> status LEDs. <br /> � S4009-0002-9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.