My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13462
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13462
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2013 11:32:29 AM
Creation date
7/22/2013 11:26:17 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
12-13462
Building Department - Name
FLORIDA HOSPITAL OF ZEPHYRHILLS
Address
7050 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 • � ► - \ ' • - <br /> Panel MOdule Selection (shaded model numbers are optional modules) <br /> � Supervisory Actual Alarm Current Actual Alarm <br /> Model Description Current Supervisory <br /> 4009-9201 120 VAC input gasic Panel 85 mA 85 mA 185 mA 185 mA <br /> 4009-9301 240 VAC input <br /> +NAC loads +NAC loads <br /> 4009-9807 Additional Four Point NAC 40 mA + (add below) (add below) <br /> 4009-9808 Dual Class A Adapter(current _ _ _ — <br /> included in basic panel value) <br /> 4009-9809" IDNet Repeater 70 mA 70 mA <br /> 4009-9810*t Fiber Optic Receiver, Ciass B 65 mA + 65 mA + <br /> 4009-9811*t Fiber Optic Receiver, Class X 80 mA 80 mA <br /> IDNet Devices, 0 7 mA each, maximum of 100 Total devices + Total devices (A�) + <br /> (see note 5) x 0.7 mA each x 0.7 mA each <br /> Auxiliary Power Output, calculate per total 500 mA + 500 mA �A2� + <br /> device requirements(see note 5) maximum maximum <br /> Total Supervisory Current= (A) + <br /> Total 4009 IDNet NAC Extender Panel Alarm Current= (B1) <br /> "Only one of these three modules can be chosen for a single 4009 IDNet NAC Extender <br /> t NOTE: IDNet Fiber Optic Transmitter current is supplied from the host fire alarm control panel. <br /> NAC Loads <br /> NAC Type NAC Circuit# NAC Alarm Current <br /> Circuit 1 + <br /> Circuit 2 + <br /> Standard Panel NACS,2 A maximum per NAC (see note 5) Circuit 3 + <br /> Circuit 4 + <br /> Circuit 5 + <br /> Circuit 6 + <br /> Optional Four Point NAC Module, 1.5 A maximum per NAC(see note 5) Circuit 7 + <br /> Circuit 8 + <br /> Total NAC Loads Alarm Current= (C) <br /> Total 4009 IDNet NAC Extender Panel Alarm Current(enter 61 from above;�_ (B2) + <br /> P1'oCedul'e: Total Alarm Current= (�) <br /> 1. Calculate total panel supervisory current(A) <br /> 2. Calculate total panel alarm current(61)[convert mA to A,example.350 mA=0.35 A]. Copy(B1)into block(B2) <br /> 3. Calculate total NAC loads alarm current from notification appliance ratings(C). <br /> 4. Add(C)+ (B2)to determine total alarm current(D). <br /> 5. Total of IDNet Device Current(A1)+Auxiliary Power Output Current(A2)+ NAC Loads Alarm C;urrent(C)is 8 A <br /> maximum. <br /> 6. Refer to Simplex battery selection document 900-012 for recommended battery size for specific standby requirements <br /> (i.e 24 hours supervisory, 5 minutes of alarm). Internal cabinet space is provided for batteries up to 12.7 Ah <br /> Tyco is a registered trnden:ark of Tyco International Services GntbH and is used under license.Srmplex,the Sintplex logo,L feAlarm,IDNet,W ALKTEST,SntartSync,and <br /> TraeAlert nre trademarks ofTyco Internanonal Ltd nnd its affilrates and are used zmden c�ense. <br /> S.7�S i m p I Ex SimplexGrinnell LP Wesfminster•Westminster,MA•01441-0001•USA S4009-0002-9 <br /> www.simplexgrinnell.com <br /> G 2011 Tyca.All rights r�eserved All specifrcations nnd other inforniation shown were ct�rrent ns ofdoam�ent revision da�e and nre subject to change wrthout notice. <br />
The URL can be used to link to this page
Your browser does not support the video tag.