My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13716
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13716
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/13/2013 1:54:42 PM
Creation date
9/13/2013 12:05:59 PM
Metadata
Fields
Template:
Building Department
Company Name
LOAN FUNDING SOLUTIONS II LLC
Building Department - Doc Type
Permit
Permit #
12-13716
Building Department - Name
LOAN FUNDING SOLUTIONS II LLC
Address
38130 PRETTY POND RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' dn-6927.a <br /> FCPS-24S6(C/E) � FCPS- � N ()T I F I E ��R <br /> 24S8(C/E) � <br /> 6- � s•Amp 24-vo�t by H o n eywe I I <br /> Remote Power Su lies <br /> General <br /> The FCPS-24S6E (6-amp) and FCPS-24SSE (8-amp) are <br /> remote power supplies with battery charger The FCPS-24S6/- <br /> 24S8 may be connected to any 12 or 24 volt fire alarm control <br /> panel (FACP) or may be used as stand-alone supplies. Pri- <br /> mary applications include notification appliance (beil) circuit <br /> (NAC)expansion(to support ADA requirements and NAC syn- <br /> chronization) or auxiliary power to support 24 volt system <br /> accessories. The FCPS-24S6/-24S8 provides regulated and <br /> filtered 24 VDC power to four notification appliance circuits ;. <br /> configured as either four Class B(Style Y)or Class A(StyVe Z, <br /> with ZNAC-4 option module) Alternately, the four outputs may <br /> be configured as ali non-resettabie, all resettable or two non- <br /> resettable and two resettabie. The FCPS-24S6/-24S8 also <br /> contains a battery charger capable of charging up to 18 AH <br /> batteries. FCPS-24S6C& FCPS-24S8C are ULC-listed. <br /> IJOTE: Unless otherwise specified, the terms FCPS-24S6 and <br /> FCPS-24S8 used in thrs document refers to the standard FCPS- <br /> 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the <br /> FCPS-24S6E and FCPS-24S8E <br /> � <br /> Features • Includes integral battery charger capable of charging up to <br /> • UL-Listed NAC synchronization using System Sensor, 18 AH batteries. Cabinet capable of housing 7 0 AH batter- <br /> Wheelock, or Gentex"Commander�"appiiances. ies. <br /> • Operates as a "sync-follower" or as a "sync-generator" • Battery charger may be disabled via DIP switch for applica- <br /> (default) See note on page 2. tions requiring larger batteries. <br /> • Contains two fuily-isolated inpuUcontrol circuits - triggered • Fixed, clamp-type terminal blocks accommodate up to 12 <br /> from FACP NAC (NAC expander mode) or jumped perma- AWG(3.1 mm2)wire. <br /> nentiy"ON"(stand-aione mode). <br /> • Four Class B (Style Y) or four Class A (Style Z, with Specifications <br /> ZNAC-4 module) NACs. Primary(AC}Power: <br /> • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8} full laad out- <br /> put, with 3 amps maximum/circuit, in NAC expander mode ' FCPS-24S6Cl-24S8C 120 VAC,60 Hz,3.2A maximum. <br /> (UL 864) • FCPS-24S6E/-24S8E. 240 VAC, 50 Hz, 1 6A maximum. <br /> • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous • Wire Size minimum#�14 AWG(2.Omm2)with 600 V insula- <br /> output in stand-alone mode(UL 1481) tion. <br /> • Compatible with coded inputs;signals passed through. Control Input Circuit: <br /> • Optional power-supervision relay(EOLR-1) • Trigger Input Voltage: 9 to 32 VDG <br /> • In stand-alone mode, output power circuits may be config- . Trigger Current: 2.0 mA(16-32 V), Per Input: 1 0 mA(9 <br /> ured as: resettabie, (reset line from FACP required), -16 V). <br /> non-resettable,or a mix of two and two. Trouble Contact Rating: 5 A at 24 VDC <br /> • Fully regulated and filtered power output- optimai for pow- Auxiliary Power Output: Specific app(ication power 500 mA <br /> ering four-wire smoke detectors, annunciators, and other <br /> system peripherais requiring regulated/filtered power maximum. <br /> • Power-limiting technology meets UL power-limiting require- Output Circuits: <br /> ments. • +24 VDC filtered, regulated. <br /> • Form-C normally-closed trouble relay. • 3.0 A mauimum for any one circuit. <br /> • Fully supervised power supply,battery,and NACs. • Total continuous current for all outputs(stand-alone mode): <br /> • Selectable earth fault detection. —FCPS-24S6: 4 0 A ma�cimum. <br /> • AC trouble report selectable for immediate 2-hour delay. —FCPS-24S8: 6 0 A maximum. <br /> • Works with virtuaily any UL 864 fire alarm control which uti- • Totai short-term current for all outputs(NAC expander mode). <br /> lizes an industry-standard reverse-polariry notification cir- _FCPS-24S6. 6.0 A maximum. <br /> cuit(including unfiltered a�d unregulated bell power). <br /> Requires input trigger voltage of 9-32 VDC —FCPS-24S8: 8.0 A m�imum. <br /> � Secondary Power(Battery)Charging Circuit: <br /> • Self-contained in compact, locking cabinet- 15"H x 14.5"W <br /> x 2.75"D(cm:38 1 H x 36.83W x 6.985D) • Supports lead-acid batteries only. <br /> • Float-charge voltage. 27 6 VDC <br /> dn-6327:a•04/30/09—Page 1 ot 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.