Laserfiche WebLink
' DN-6935.D•H-2Q2 <br /> FSP-851 (A) Ser�es �� N QT 1 F f E R�R <br /> intelligent Plug-In Photoelectr�c <br /> Smoke Detectors with FlashScanO by H a r�eywe I( <br /> � - <br /> General <br /> Notifier FSP-851(A) Series intelligent plug-in smoke detectors =; �� . <br /> with integral communication provide features that surpass co�- <br /> ventional detectors. Detector sensitivity can be programmed in <br /> the control panel software. Sensitivity is continuously monitored <br /> and reported to the panel. Point ID capability allows each detec- <br /> tor's address to be set with rotary, decimal address switches, <br /> providing exact detector location for selective maintenance <br /> when chamber contamination reaches an unacceptable level. <br /> The FSP-851(A) photoelectric detector's unique optical sensing �•� <br /> chamber is engineered to sense smoke produced by a wide <br /> range of combustion sources. Dual electronic thermistors add <br /> 135°F (57°C) fixed-temperature thermal sensing on the FSP- _ <br /> 851 T(A) The FSP-851 R(A)is a remote test capabie detector for <br /> use with DNR(A)/DNRW duct detector housings. FSP-851(A) m <br /> series detectors are compatible with Notifier Onyx and CLIP FSP-851(A) In B210LP(A} Base <br /> series Fire Alarm Control Panels(FACPs) <br /> FlashScanO(U S. Patent 5,539,389)is a communication proto- _gp00SR(A):6.875"(17 46 cm)diameter <br /> col developed by Notifier that greatly increases the speed of _g�4RB(A):6.2'(15.748 cm)diameter <br /> communication between analog intelligent devices. Intelligent <br /> devices communicate in a grouped fashion. If one of the devices —g�461(A):6.2"(15.748 cm)diameter <br /> in the group has new information, the panel's CPU stops the Shipping Wefght:5.2oz. (147g). <br /> group poll and concentrates on singie points. The net effect is Operating Temperature range: FSP-85i(A), 0°C to 49°C <br /> response speed greater than five times that of earlier designs. (32°F to 120°F). FSP-851 T(A), 0°C to 36°C (32°F to 100°F). <br /> Low temperature signal for FSP-851T(A) at 45°F +/- 10°F <br /> Features (722°C+/-5.54°C). FSP-851 R(A)installed in a DNR(A)/DNRW, <br /> • Sieek, low-profile design. -20°C to 70°C(-4°F to 158°F). <br /> • Addressable-analog communication UUULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/ <br /> Stable communication technique with noise immunity. min.),suitable for installation in ducts. <br /> • Low standby current. Relative Humidity: 10%-93%noncondensing. <br /> • Two-wire SLC connection. Thermal Ratings: Fixed-temperature setpoint 135°F(57°C) <br /> • Compatible with FlashScanO and CLIP protocol systerr�s. DETECTOR SPACING AND APPLlCAT10/YS <br /> • Rotary, decimal addressing(1-99 on CLIP systems, 1-159 on Notifier recommends spacing detectors in compiiance with <br /> FlashScan systems) NFPA 72. In low airflow applications with smooth ceiiing, space <br /> • Optlonal remote,single-gang LED accessory. detectors 30 feet (9 144m) fior ceiling heights 10 feet (3.148m) <br /> • Dual LED design provides 360°viewing angie. and higher For specific information regarding detector spacing, <br /> • Visible bi-color LEDs blink green every time the detector is P�acement, and special applications refer to NFPA 72. System <br /> addressed, and iliuminate steady red on alarm (FlashScan Smoke Detector Application Guide, document A05-1003, is <br /> systems only). available at systemsensor.com <br /> • Remote test feature from the panel. ELECTRIEAL SPECIFICATIONS <br /> • Walk test with address display (an address on 121 will blink Voltage Range: 15-32 volts DC peak. <br /> the detector LED� 12-[pause]-1(FfashScan systems only). Standby Current(max. avg.): 300uA @ 24VDC (one commu- <br /> • Built-in functional test switch activated by external magnet. nication every five seconds with LED enabled) <br /> • Built-in tamper-resistant feature. LED Current(max.):6.5mA @ 24 VDC("ON") <br /> • Sealed against back pressure. <br /> • Constructed of off-white fire-resistant plastic, designed to �nstallation <br /> commercial standards,and offers an attractive appearance. <br /> • 94-5V plastic flammabi(ity rating. FSP-851(A) plug-in detectors use a separate base to simpiify <br /> SEMS screws for wiring of the separate base. instailation, service, and maintenance. A special tool allows <br /> � maintenance personnel to plug in and remove detectors without <br /> • Optional relay, isotator, and sounder bases. using a ladder <br /> Mount base(all base types)on an electrical backbox which is at <br /> Specifications least 1 5" (3.81 cm) deep. For a chart of compatibVe junction <br /> Sensitivity:0.5%to 2.35%per foot obscuration boxes,see DN-60054 <br /> Size:2.1" (5.3 cm)high; base determines diameter NOTE: 1) Because of inherent supervision provided by ihe SLC <br /> loop, end-of-line resistors are not required. Wiring 7-taps" or <br /> —B210LP(A):6 1" (15.5 cm)diameter branches are permrtted for Style 4 (Class 'B) wiring. 2) When <br /> —8501(A):4 1"(10 4 cm)diameter using relay or sounder bases, consuft the ISO-X(A) installafion <br /> —6200S(A):6.875"(17 46 cm)diameter. <br /> DN-6935:D•12/U82011—Page 1 of 2 <br />