Laserfiche WebLink
� Corporate Office and Remittance: <br /> . w . 2150 Rosedale Road, Quakertown, PA 18951 <br /> PA Contr.#PA019043 <br /> Florida Branch Office: <br /> 29716 US Highway 27, Dundee, FL 33838 <br /> Florida Contr #CCC1325665 FL Business Lic. #23289 <br /> Jurin Roofing Services, Inc. Tel (800)710-7525 Fax(215)536-2661 www.jurinroofing.com <br /> 6. Contract Provisions and Exclusions (conx) <br /> 6.3 Dispute Resolution - In the event of a dispute between the parties hereto, the parties shall seek to <br /> mediate the dispute. If inediation is not successful, arbitration shall be promptly conducted. Both <br /> mediation and arbitration shall be held in the county where the Project is located. <br /> 6.4 Electrical Conduit- Owner represents there is no electrical conduit embedded within the existing <br /> roofing to be removed or attached directly to the underside or topside of the roof deck upon which <br /> contractor will be installing the new roof. Owner will indemnify Jurin Roofing Services, Inc. from <br /> any personal injury, damage, claim or expense because of the presence of electrical conduit, shall <br /> render the conduit harmless so as to avoid injury to Jurin Roofing Services, Inc. personnel, and shall <br /> compensate Jurin Roofing Services Inc. for additional time and expense resulting from the presence of <br /> such materials. <br /> 6.5 Fumes and Emissions - Customer acknowledges that roofing involves the use of solvent based materials. <br /> Odors and emissions from roofing products will be released and noise will be generated as part of the <br /> roofing operations to be performed by Jurin Roofing Services, Inc. Customer shall be responsible for <br /> interior air quality, including controlling mechanical equipment, HVAC units, intake vents, wall vents, <br /> windows, doors and other openings to prevent fumes and odors from entering the building. Customer <br /> is aware that roofing products emit fumes, vapors and odors during application process. Customer <br /> shall indemnify and hold harmless Jurin Roofing Services, Inc. from claims from third parties relating <br /> to fumes and odors that are emitted during the normal roofing process. <br /> 6.6 Indemnify and Hold Harmless Clause - Jurin Roofing Services, Inc. agrees to indemnify and hold <br /> harmless the Owner from all claims, damages, losses and expenses for personal injury, including death <br /> and property damage, to the extent caused by a negligent act or omission by Jurin Roofing Services, <br /> Inc. or someone for whose acts Jurin Roofing Services, Inc. is responsible. Jurin Roofing Services, <br /> Inc. is not obligated to provide indemnity for damages, losses, claims or expenses to the extent due to <br /> the negligence or fault of indemnities or others for whose conduct Jurin Roofing Services, Inc. is not <br /> responsible. Similarly, Owner shall indemnify and hold harmless Jurin Roofing Services, Inc. from all <br /> claims for bodily injury, including death or other damages, to the extent due to the negligence of <br /> Owner or the fault of its agents, representatives or employees. Owner agrees to hold harmless and <br /> indemnify Jurin Roofing Services, Inc. from any and all future construction defect claims. <br /> 6.7 Mold growth exclusion - Jurin Roofing Services, Inc. and Owner are committed to acting promptly so <br /> that roof leaks are not a source of potential interior mold growth. Owner will make periodic <br /> inspections for signs of water intrusion and act promptly, including notice to Jurin Roofing Services, <br /> Inc., if Owner believes there are roof leaks, to correct the condition. Upon receiving notice Jurin <br /> Roofing Services, Inc. will make repairs promptly so that water entry through the roofing installed by <br /> Jurin Roofing Services, Inc. is not a source of moisture. Jurin Roofing Services, Inc. is not <br /> responsible for indoor air quality. Owner shall hold harmless and indemnify Jurin Roofing Services, <br /> Inc. from claims due to poor indoor air quality and resulting from a failure by Owner to maintain the <br /> interior of the building in a manner to avoid growth of mold. <br /> 6.8 Customer acknowledges that tear-off of existing roofing materials and re-roofing of an existing building <br /> may cause disturbance, dust or debris to fall into the interior. Customer agrees to remove or protect <br /> property directly below the roof in order to minimize potential interior damage. Jurin Roofing <br /> Services, Inc. shall not be responsible for disturbance, damage, and cleanup or loss of use or loss to <br /> PRJ#2290: Townview Center-TJ MAXX—Penthouse Removal Page 3 of 5 <br />