Laserfiche WebLink
-�- wrightsoft� <br /> Manual S Compliance Report Da e; R0313082 <br /> , Right Unit sY: TMN <br /> Ryman Construction <br /> 36413 SR 54,2ephyfiills,FL 33541 Phone:813-782-0825 <br /> � � ` � • <br /> For: Driftwood Townhomes <br /> Zephyrhills, FL <br /> • • • • � <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 16374 Btuh Entering coil DB: 81.2°F <br /> Outdoor design WB: 77.3°F Latent gain: 4247 Btuh Entering coil WB: 65.8°F <br /> Indoor design DB: 75.0°F Total gain: 20621 Btuh <br /> Indoor RH: 50% Estimated airflow: 780 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Rheem or Equiv. Model: RPNL-024JAZ+RHSL-HM2417++RCSL-H`2417 <br /> Actual airflow: 780 cfm <br /> Sensible capacity: 17550 Btuh 107% of load <br /> Latent capacity: 5850 Btuh 138% of load <br /> Total capacity: 23400 Btuh 113% of load SHR: 75% <br /> • • . <br /> Design Conditions <br /> Outdoor design DB: 42.5°F Heat loss. 12691 Btuh EMering coil DB: 68.0°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data a�Actual Design Conditions <br /> EquipmeMtype: SpIitASHP <br /> Manufacturer: Rheem or Equiv. Model: RPNL-024JAZ+RHSL-HM2417++RCSL-H"2417 <br /> Actual airtlow: 780 cfm <br /> Output capacity: 22800 Btuh 180% of load Capacity balance: 34 °F <br /> SupplemeMal heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airtlow: 780 cfm <br /> Output capacity: 5.0 kW 134% of load Temp. rise: 0 °F <br /> The above equipmerrt was selected in accordance with ACCA Manual S. <br /> ,;� wri htsoft` 2073-Mar-1814:54:36 <br /> 9 Right-SuRe�Universal 2012 12.1.05 RSU07440 <br /> Page 2 <br /> �`C�\HVAC\aWork File1R0313082-Driftwood Townhomes\R0313082.rup Calc=MJ8 House Front faces: S <br />