Job: R0313082 <br /> � wri htsofC Project Summary Date: <br /> 9 Left Unit By: TMN <br /> � Ryman Construction <br /> 36413 SR 54,2ephyrhips,FL 33541 Phone:813-782-0825 <br /> ° • ' � � <br /> For: Driftwood Townhomes <br /> Zephyrhills, FL <br /> Notes: Load Calculation was obtained from an electronic copy of drawing. <br /> 6 - • � • <br /> Weather� Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 43 °F Outside db 91 ''F <br /> Inside db 70 °F Inside db �5 'F <br /> Design TD 28 °F Design TD 16 °F <br /> Daily range � <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 9232 Btuh Structure 10402 Btuh <br /> Ducts 1963 Btuh Ducts <br /> Central vent(49 cfm) 1496 Btuh Central vent (49 cfm) 887 Btuh <br /> Humidification 0 Btuh Blower 4096 Btuh <br /> p�pin9 0 Btuh <br /> Equipment load 12691 Btuh Use manufacturer's data Y <br /> Rate/swing multidier 1.00 <br /> 111flltration Equipment sensible load 17263 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Tight <br /> Fireplaces 0 Structure 1263 Btuh <br /> Ducts <br /> Heating Cooling Central verrt(49 cfm) 1839 Btuh <br /> Area(ftz 1374 1374 Equipment latent load 4247 Btuh <br /> Volume�ft') 10993 10993 <br /> Air changes/hour 0.16 0.08 Equipment total load 21510 Btuh <br /> Equiv.AVF(cfm) 29 15 Req.total capacity at 0.75 SHR 1.9 ton <br /> Heating Equipment Sumrr�ary Cooling Equipment Summary <br /> Make Rheem or Equiv. Make Rheem or Equiv. <br /> Trade Split System HP Trade Split System HP <br /> Model RPNL-024JAZ Cond RPNL-024JAZ <br /> AHRI ref 3544211 Coil RHSL-HM2417++RCSL-H*2417 <br /> AHRI ref 3544211 <br /> Efficiency 8.5 HSPF E�ciency 11.0 EER, 13 SEER <br /> Heating input Sensible cooling 17550 Btuh <br /> Heating output 22800 Btuh @ 47°F Latent cooling 5850 Btuh <br /> Temperature rise 27 °F Total cooling 23400 Btuh <br /> Actual air flow 78�J cfm Actual air flow 780 cfm <br /> Air flow factor 0.070 cfm/Btuh Air flow factor 0.064 cfMBtuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.80 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> 2013-Mar-18 14:54:36 <br /> .ti, '�' wrightsoft' Righl-Suite�Universal 2012�2.1.05 RSU07440 Page 1 <br /> �A C:\HVAC\aWork File\R0313082-Driftwood Townhomes1R0313082.rup Calc=MJ8 House Front faces: S <br />