My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14032
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14032
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2014 11:46:36 AM
Creation date
3/24/2014 11:46:33 AM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
13-14032
Building Department - Name
RYMAN CONSTRUCTION INC
Address
6773 BASSWOOD CIR LOT 20
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job: R0313082 <br /> � wri htsoft• Project Surr�rr�ary Date: <br /> 9 Right Unit By: TMN <br /> � Ryman Construction <br /> 36413 SR 54,Zephyrtrills,FL 33541 Phone:613782-0625 <br /> r <br /> �`: ° � ' � • <br /> For: Driftwood Townhomes <br /> Zephyrhills, FL <br /> Notes: Load Calculation was obtained from an electroniccopy of drawing. <br /> �: � . . <br /> Weather Tampa International AP, FL, US <br /> Winter Design Conditior�s Summer Design Conditions <br /> Outside db 43 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 28 °F Design TD 16 °F <br /> Daily range � <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 9232 Btuh Structure 9990 Btuh <br /> Ducts 19G3 Btuh Ducts 1402 Btuh <br /> Central vent(49 cfm) 1496 Btuh Cer�tral vent(49 cfm) 887 Btuh <br /> Humidification 0 Btuh Blower 4096 Btuh <br /> Piping 0 Btuh <br /> Equipment load 12691 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 16374 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Tight <br /> Fireplaces 0 Structure 1145 Btuh <br /> Ducts 1263 Btuh <br /> Heating Cooling Central vent(49 cfm) 1839 Btuh <br /> Area(ft2) 1374 1374 Equipment latent load 4247 Btuh <br /> Volume(ft') 10993 10993 <br /> Air changes/hour 0.16 0.08 Equipment total load 20621 Btuh <br /> Equiv.AVF (cfm) 29 15 Req.total capacity at 0.72 SHR 1.9 ton <br /> Heating Equipment Sumr� ary Cooling Equipment Summary <br /> Make Rheem or Equiv. Make Rheem or Equiv. <br /> Trade Split System HP Trade Split System HP <br /> Model RPNL-024JAZ Cond RPNL-024JAZ <br /> AHRI ref 3544211 Coil RHSL-HM2417++RCSL-H"2417 <br /> AHRI ref 3544211 <br /> Efficiency 8.5 HSPF Efficiency 11.0 EER, 13 SEER <br /> Heating input , Sensible cooling 16848 Btuh <br /> Heating output 22800 Btuh @ 47°F Latent cooling 6552 Btuh <br /> Temperature rise 27 °F Total cooling 23400 Btuh <br /> Actual air flow 780 cfm Actual air flow 780 cfm <br /> Air flow factor 0.070 cfm/Btuh Air flow factor 0.068 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.79 <br /> Calculations approveci by ACCA to meet all requirements of Manual J 8th Ed. <br /> .t WI'1 �1t50'f� 2013-Mar-1814:54:36 <br /> ��+ � 9 Right-Suite�Universal 2012 12.1.05 RSU07440 Page 2 <br /> ""`^`C:\HVAC\aWork File\R0373082-DriTtwood Townhomes\R0313D82.rup Calc=MJ8 House Front faces: 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.