My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14344
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14344
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2014 10:25:19 AM
Creation date
4/23/2014 10:25:16 AM
Metadata
Fields
Template:
Building Department
Company Name
POPEYES
Building Department - Doc Type
Permit
Permit #
13-14344
Building Department - Name
COHEN,RICHARD TRST & WILLIAM JEN
Address
7441 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION IV — SVSTE�11 DESIGN <br /> UL EX3470 ULC EX3470 Page 4-43.4 <br /> ■ 7-1-09 REV,0 <br /> OVERLAPPING NOZZLE COVERAGE(Continued) <br /> �Overlapping Coverage—Option 2 General Design Limltatlons <br /> For each group of protected applianceS under a common hood(s), . �f overlapping appliance protection is mixed with dedicated appli- <br /> the overlapping nozzles must be located from right to leR so that ance protection on the same pipe system,THE OVERLAPPING <br /> each end nozzie is located a maximum of 11.5 in.(29.2 cm)inside APPLtANCE PROTECTION PIPING REQUIREMENTS MUST <br /> the outside edge of the cooking hazard of each end appliance,and gE FOLLOWED. <br /> the inside overlapping nozzles must be located between the two <br /> �end nozzles at a maximum spacing of 25.5 in.(64.8 cm). '• Overlapping protection requires the �se of 3.0 gal (1 i.4 l.) <br /> Hazard Zone tank(s)and a maximum of six(6)flows per tank. <br /> The hazard zone is defined as a theorelical,flat and level,rectan- ' In installations using tanks only intended for overlapping protec- <br /> guEar surface,that includes all of the cooking hazards of the pro- tion,a single Double Tank nitrogen expellant gas cartridge can <br /> tected appliances under a common hood(s).The purpose of the be utilized with up to three(3)3.0 gal(11.4 L)tanks. <br /> hazard zone is to provide a means of Iocating the applfances and • In installations using both overlapping protection and conven- <br /> the overlapping nozzles, as well as aiming the overlappfng noz- tional non-overlapping protection (ex. hood/duct or dedicated <br /> zles.The hazard zone measures 28 in. (7i 1 mm} deep by the appliance protection), a single Double Tank nitrogen expellant <br /> length of the cooking hazard(s).The cen#erline of the hazard zone gas cartridge can be utilized wlth up to three(3)3.0 gal(19 4 L) <br /> must bisect ihe 28 in.(711 mm)depth(from(ront to back)and run tanks,as long as none of the 3.0 gal (11.4 L) tanks exceed a <br /> from right-to-left for the full width of lhe hazard zone. total flow output ot more than six(6)flows. <br /> • If more than six (6} flows wilV be used In a conventional non- <br /> Overlapping Nozzle Appliance Protection overlspping tank, it cannot share the same cartridge as tanks <br /> Overlapping Nozzle Appliance Protection is defined as protection intended for overlapping protection. In this case,an additionaf <br /> of coolcing appliances by nozzles spaced uniformly at unitorm ele- Regulated Actuator Assembly with another expellant gas car- <br /> vations under a common hood(s).Overlapping protection of appli- ► tridge will be required. <br /> ances is continuous for the tull length of the hood or divided when . �e 245 nozzle,Part No.419340,must be used for"end of zone" <br /> group(s) of protected appliances are separated by coun#ers or protection. <br /> applfences not requiring protection. <br /> Futl hood contlnuous protection is defined as overla in noz- ' The 280 nozzle, Part IVo.419341, must be used for zone pro- <br /> pP 9 tection. <br /> zle appliance proteCtion that covers the appliance line-up located <br /> under the total hood length.All appliances requlring protection are ' ' Maximum depth of zona is 28 in.(71.1 cm). <br /> the appliances under the hood that can be an ignition source of • Refer to overlapping system piping requiremants listed ln Table 2. <br /> grease in the hood,grease removak device or the duct. ► . Nozzle must be located 0 in.to 12 in.(0 cm to 30.5 cm)forward <br /> Group protection is defined as overlapping nozzle appliance pra of zone centerline,aimed back at the zone centerline. <br /> tection that protects individual hazard zones located under a com- . . Nozzles must be spaced a maximum of 11.5 in.(29.2 cm)from <br /> mon hood.These "groups" of appliances may be separated by � <br /> appliances noF requiring protection,such as steam equipment or each end of hazard and then a maximum of 25.5 in.(64.8 em) <br /> work iables, or by dedicated appliance protection,such as sala- on center for the remaining overlapping nozzles until the com- <br /> mander broilers. plete hazard is covered. <br /> �See Figure 95 {full hood continuous protection) and Figure 96 <br /> (multiple group protection). • �or appliance hazard surfaces with Ilsted protection exceed- <br /> ing ihe standard hazard ione of 28 in.(71 cm)in depth,the haz- <br /> Dedlcated�lozzle Appliance Protectlon ard surface(s)must be aligned with the back edge of the hazard <br /> Appliance protection using dedicated nozzle coverage is defined zone,with the front edge overhanging the front edge of the zone. <br /> as protection of cooking appliances with enclosed cooking haz- See Appliance Chart,Table 1. <br /> ards, such as upright broilers, which cannot be protected with • For appliance hazard surfaces that exceed the Ifstect protec- <br /> averlapping nozzles and therefore must be proiected with nozzles tlon sizes, multiple zones must be utilized.Align entire hazard <br /> dedicated to the appliance. surface area within the multiple zones. <br /> • All hood,duct,and individual appliance prokection are as speci- <br /> fied in the R-102 Design, InstaAation, Recharge and Mainten- <br /> ance Manual,Part No.418087. <br /> • All appllance protection currentiy listed in the R-102 Design <br /> Manual,Part No.418087,is also approved protection.Zone pro- <br /> tection can be consldered optional protection. <br />
The URL can be used to link to this page
Your browser does not support the video tag.