My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14582
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14582
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2014 10:42:21 AM
Creation date
6/12/2014 10:42:18 AM
Metadata
Fields
Template:
Building Department
Company Name
DIALYSIS CENTER
Building Department - Doc Type
Permit
Permit #
13-14582
Building Department - Name
BILL NYE REAL & SIMPLY THREE LL
Address
36819 EILAND BLVD UNIT 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ANIV-8US DEVlCE ADDRESSING After calculating the total worst case current draw,the following <br /> Each ANN-BUS device requires a unique address(ID Number) table specifies the maximum distance the modules can be <br /> in order to communicate with the FACP A maximum of 8 devices �ocated from the FACP on a single wire run. The table ensures <br /> can be connected to the FACP ANN-BUS communication circuit. 6.0 volts of line drop maximum.In general,the wire length is lim- <br /> See the FACP manual for more information ited by resistance,but for heavier wire gauges, capacitance is <br /> the limiting factor. <br /> WIRE REQUIREME/VTS:COMMUIVlCATIONS CIRCUIT These cases are marked in the chart with an asterisk('). Maxi- <br /> The N-ANN-80 connects to the FACP ANN-BUS communica• mum length can never be more than 6,000 feet (1,800 m), <br /> tions circuit. To determine the rype of wire and the maximum wir- regardless of gauge used. See table below. <br /> ing distance that can be used with FACP ANN-BUS accessory w�RE REQUIREMENTS:POWER ClRCUIT <br /> modules,it is necessary to calculate the total worst case current <br /> draw for all modules on a single 4-conductor bus.The total worst • 14 to 18 AWG(0.75-2.08 mm2)wire for 24 VDC power cir- <br /> case current draw is calculated by adding the individual worst cuit is acceptable. <br /> case currents for each module. • All connections are power•limited and supervised. <br /> NOTE: For tota/worst case current draw on a srngle ANN-8US • A maximum of eight N-ANN-80 modules may be connected <br /> reler to appiopriate FACP manual. to this circuit. <br /> Communication Pair Wiring Distance: FACP to LastANN-BUS Module <br /> Total Worst Case p2 Gauge 18 Gauge 16 Gauge 14 Gauge <br /> Current Draw(amps) <br /> 0.100 1,852 ft. 4,688 fl. '6,000 ft. •6,000 fl. <br /> 0.200 926 R. 2,344 R. 3,73�ft. 5,906 ft. <br /> 0.300 617 R. 1,563 ft. 2,488 k. 3,937 fl. <br /> 0.400 463 fl. 1,172 ft. 1,866 fl. 2,953 R. <br /> 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. <br /> 0.600 309 ft. 781 ft. 1,244 R. 1,969 ft. <br /> 0.700 265 ft. 670 ft. 1,066 ft. 1,687 fl. <br /> 0.800 231 H. 586 ft. 933 ft. 1,476 ft. <br /> 0.900 206 ft. 521 ft. 629 k. 1,312 ft. <br /> 1 000(max.) 185 ft. 469 ft. 746 ft. 1,161 ft. <br /> WIRlNG CONFIGURATlOIV ORDERING OPTIDNS: <br /> The following figure iliustrates the wiring between the FACP and N-ANN-80:Black 80 character LCD Annunciator. <br /> ANN-BUS devices. N-ANN-80-W:White,80 character LCD Annunciator <br /> ANN-BUS and power ANN-SBBOKIT B: Black surface mount backbox with angled <br /> wiring are supervised wedge. <br /> and power-limited. ANN-SBBOKIT W: White surface mount backbox with angled <br /> � e A . _ wedge. <br /> TB1 <br /> 4 3 7 <br /> ANN-BUS Device <br /> . O <br /> NFW-50 Te� <br /> I 2 3 A 5 6 7 B <br /> FACP Wiring to ANN-BUS Device <br /> 92009 by Honeywell Inlernational Inc.All rights reserved.Unauthorized use <br /> of Ihis document is striclly prohibited. <br /> 1S0 9001 This document is not intended to be used for installation purposes. <br /> We try to keep our product information up-to•date and accurate. <br /> We cannot cover all specitic applications or anticipate all requiremenis. <br /> EN6IAEEAINB 8 MANIIFACIBRIN6 All specifications are subject to change without notice. <br /> QUALITY SYSiEMS MadeintheU.S.A. <br /> For more intormation,contacl Notifier.Phone:(203)484-7161,FAX (203)484-7118. <br /> www.notifier.com <br /> Page 2 of 2—dn-7114:c•5/22/09 <br />
The URL can be used to link to this page
Your browser does not support the video tag.