DN-6997:C•A1-320
<br /> NH-100(A) Series �� � �' � 1 � :�;
<br /> Intell�gent Addressable Thermal
<br /> Detectors for FireWarden Series by Honeywell
<br /> General _ . - ..•�._ . _
<br /> The NOTIFIER NH-100(A) Series thermal detectors are � ' � ' ' ,
<br /> addressable sensors that use a state-of-the-art thermistor �`� �
<br /> sensing circuit for fast response.These sensors provide open- � �_'��- ��. . � ' � '
<br /> r�2
<br /> area protection and are intended for use wilh the FireWarden ' �,,:.,.� � ..-:._� ,�:���`:,. -
<br /> Series (FireWarden-100-2 and FireWarden-50) and Spartan . ' - � }� . �„�rs.{;��.,;<�,;...}� <:�%:A;;,:a.;_
<br /> (NSP-25)addressable Fire Alarm Control Panels(FACPs) �;���h�4=` . , ��`f•- ���.�.�"�'.,,,':<i�?i,+R' �
<br /> �� r: � ,lf-rb � �
<br /> ';�,�.' , I,r. �l,.��k:•�'i�9�� �
<br /> The NH-100(A) and NH•100R(A)sensors provide fixed tem- �1�'f. , _� =:: .,,,.j�,+. -
<br /> perature alarm detection at 135°F (57°C). The NH-100R(A) • , ,. :,::_�z'•._;,_, ,;?,::;_,�;�:�'•/
<br /> sensor also responds to rate-of-rise conditions of greater than �'
<br /> 15°F(8.3°C)per minute. The NH-100H(A)is a fixed high-tem- �'r..�:•-�`'`"'�"j`��;,
<br /> 0 0 �'�• c i'•.,:;,Y/1'`,� g
<br /> perature detector that activates at 190 F (88 C) These ther- ;� ='-_: ;�,.,t -
<br /> mal detectors provide addressable property proiection in a
<br /> variety of applications. NH-100(A)in B210LP(A) Base m
<br /> Two LEDs on each sensor light to provide a local,visible sen-
<br /> sor indication.Remote LED annunciator capabiliry is available
<br /> as an optional accessory,RA100Z. • Low standby current.
<br /> • 94-SV plastic flammability rating.
<br /> F'eatures Optlons:
<br /> SLC loop: • Remote LED output connection to optional RA100Z remote
<br /> • Two-wire SLC loop connection. LED annunciator.
<br /> • Unit uses base for wiring. • Flanged surface mounting kit.
<br /> addressiny: Installation
<br /> • Addressable by device.
<br /> Rotary,decimal addressing: 01 -99 with FireWarden-100- NH-100(A) Series plug-in intelligent thermal detectors use a
<br /> • 2,NSP-25,01 -50 with FireWarden-50. detachable base to simplify installation, service and mainte-
<br /> nance.Installation instructions are shipped with each detector
<br /> Architecture: Mount base(all base types)on an electrical backbox which is
<br /> � Sleek,low-protile,srylish design. at least 1.5"(3.81 cm)deep.For a chart of compatibfe junction
<br /> • State-of-the-art thermistor technology for fast response. boxes,see ON-60054
<br /> • Integral communications and built•in device-rype identifica- NOTE:8ecause ol Ihe�nherent supervision provided by the SLC
<br /> tion. loop, end-ol-line resistors are not required. Wiring 'T-taps" or
<br /> • Built-in tamper resistant feature. branches are permifted tor Sryle 4(Class"B')wrrrng only.
<br /> • Buil[-in functional test switch activated by external magnet. A�lpI1C1t1011S
<br /> Operation:
<br /> • Factory preset at 135°F(57°C)for the NH-100(A)and NH- Use thermal detectors for protection of property.
<br /> 100R(A); 190°F(88°C)for the NH-t00H(A). (�onstruction
<br /> • Rate-of-rise triggers at 15°F(8.3°C)per minute for the NH-
<br /> 100R(A) These detectors are constructed of off-white fire-resistant
<br /> • 360°-tield viewing angle of the visual alarm indicators(two Plastic. The NH-100(A) Series plug-in intelligent thermal
<br /> bicolor LEDs) LEDs blink green in Normal condition and detectors are designed to commercial standards and offer an
<br /> turn on steady red in Alarm attractive appearance.
<br /> • Visible�EDs"blink"every time the unit is addressed. Operation
<br /> Mechanicals;
<br /> • Sealed against back pressure. Each NH-100(A)Series detector uses one of 99(FireWarden-
<br /> 100-2, NSP-25)or 50(FireWarden-50)possible addresses on
<br /> • SEMS screws for wiring of the separate base. a control panel SLC loop. It responds to regular polls from the
<br /> • Designed for direct-surface or electrical-box mounting. control panel and reports its type and ihe status.If it receives a
<br /> • Plugs into separate base for ease of installation and main- test command(rom the panel(or a local magnet test),it stimu-
<br /> tenance. lates its electronics and reports an alarm. It blinks its LEDs
<br /> � Separate base allows interchange of photoelectric, ioniza- when polled and turns the LEDs on when commanded by the
<br /> tion and thermal sensors. panel.The NH-100(A) Series offers features and performance
<br /> that represent the latest in thermal detector technology.
<br /> Other system features:
<br /> • Remote test feature from the panel.
<br /> � Walk test with address display
<br /> ON-699TC•12l07i2011—Pa9e 1 of 2