My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14582
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14582
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2014 10:42:21 AM
Creation date
6/12/2014 10:42:18 AM
Metadata
Fields
Template:
Building Department
Company Name
DIALYSIS CENTER
Building Department - Doc Type
Permit
Permit #
13-14582
Building Department - Name
BILL NYE REAL & SIMPLY THREE LL
Address
36819 EILAND BLVD UNIT 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Detector Sensitivity Test NP-100RA:Same as NP-100R with ULC Listing for use wilh a <br /> DNRA duct detector housing;B210LPA base included. <br /> Each detector can have its sensitivity tested (required per <br /> NFPA 72,Chapter 14 on Inspection, Testing and Maintenance) lNTELLlGENT BASES <br /> when installed/connected to a FireWarden-100-2 or FireWar- NOTE:'A"su/lix indicates ULC Lrsted modef. <br /> den-50 addressable tire alarm control panel.The results of the <br /> sensitivity test can be printed off the FireWarden-100-2 or Fire- NOTE:For details about intellrgent bases and their mounting,see <br /> Warden-50 for record keeping. DN•60054. <br /> B210LP(A): Piug-in detector base (included); standard U S <br /> Specification flanged low-profile mounting base. <br /> Voltage range: 15-32 VDC(peak) 6210LPBP:Bulk pack of B210LP;package contains 10 <br /> Standby current:300 NA @ 24 VDC 6501(A):Standard European flangeless mounting base. <br /> LED current:6.5 mA @ 24 VDC{latched"ON"). B501BP:Bulk pack of B501;package contains 10. <br /> Air velocity:4,000 ft./min.(20 m/sec.)maximum B200SR(A): Intelligent sounder base capable oF producing <br /> sound output with ANSI Temporal 3 or continuous tone. <br /> Size:2 1"(5.33 cm)high;base determines diameter Replaces 8501 BH series bases in retrofit applications. <br /> -B210LP(A):6 1"(15.5 cm)diameter 8224R6(A): Plug-in System Sensor relay base. Screw termi- <br /> -B501(A):4 1"(10.4 cm)diameter nals:up to 14 AWG(2.0 mmz) Relay type:Form•C.Rating:2.0 <br /> -6200SR(A):6.875"(17 46 cm)diameter A C� 30 VDC resistive; 0 3 A@ 110 VDC inductive; 1 0 A � <br /> -B224RB(A):62"(15.748 cm)diameter. 30 VDC inductive. <br /> Weight:3.6 oz.(102 g) g224g�(A): Plug-in System Sensor isolator detector base. <br /> Maximum 25 devices behveen isolator bases(see DN-6994). <br /> Operatfng temperature range: for NP-f00(A):0°C to 49°C ACCESSORlES <br /> {32°F to 120°F);for NP-100T(A):0°C to 38°C(32°F to 100°F). <br /> NP-fUDR(A):installed in a ONR(A)/DNRW-20°C to 70°C(-4°F F110: Retrofit fiange to convert B210LP(A) to match the <br /> to 158°F). B710LP(A) protile, or to convert older high-profile bases to <br /> Temperature:0°C-49°C(32°F-120°F) fow-profile. <br /> Relative humidity: 14%-93%,non-condensing. F110BP:Bulk pack of F 110;package contains 15. <br /> F210:Replacement flange for B210LP(A)base. <br /> LISt111gS RA100Z(A):Remote LEO annunciator 3-32 VDC.Mounts to <br /> Listings and approvals below apply to the NP-100(A), NP- a U.S. single-gang eleclricai box. For use with 6501(A) and <br /> 100T(A), and NP-100R(A) detectors. In some cases, certain B210LP(A)bases only <br /> modules may not be listed by certain approval agencies, or SMB600:Surface mounting kit <br /> listing may be in process. Consult factory for latest listing sta- M02-04-OO:Test magnet. <br /> tus. <br /> UL Listed:S 1115. M02-09-00:Test magnet with telescoping handle. <br /> • ULC Listed:S911 XR2B: Detector removal tool. Allows installation and/or <br /> CSFM:7272-0028:0231 removal of detector heads from bases in high ceiling app�ica- <br /> � tions. <br /> • MEA.243-02-E Vol.2. XP-4: Extension pole for XR26.Comes in three 5-toot (1 524 <br /> � Maryland State Fire Marshal:permit 2173. m)sections. <br /> • FM approved T55-127-010: Detector removal tool without pole. <br /> Product Line Information BCK-200B:Black detector covers for use with NP-100(A)only; <br /> box of 10. <br /> NOTE:'A"sulfix indicates ULC Listed model. WCK-2008: White detector covers for use with NP-100(A) <br /> NP-100: Adressable photoelectric detector; 6210LP base only;box of 14 <br /> included. <br /> NP-100A: Sames as NP-100 with ULC Listing;8210LPA base <br /> included. <br /> NP-100T: Same as NP-100 but with therma( element <br /> 6210LP base included. <br /> NP-100TA: Same as NP-100T with ULC Listing; 6210LPA <br /> base included. <br /> NP-100R: Remote teSt capable addressable phOt0218CtfIC NOTIFIEfiO and FireWarden� are registered trademarks o( Honeywell <br /> detector for use with a DNRA/DNRW duct detector housing; internasonai inc. <br /> 6210LP base included. o2ot� All rights reserved. Unaulhorized use of this document is strictly <br /> prohibited. <br /> '�O 9001 This document is not intended to be used for installation purposes. <br /> We try to keep our product information up•to-date and accurate <br /> _ We cannot cover all specific applications or anticipate all requirements. <br /> H�iINEEAIN6 6 MAMOFACTOAIN6 All specifications are subject to change without notice. <br /> QUAIITY SYSTFMS MadeintheU.S.A. <br /> For more information,contact Notifier.Phone:(203)484-7161.FAX.(203)484-7118. <br /> www.notifier.com <br /> Page 2 0l 2—DN-6995:C•12/07/2011 <br />
The URL can be used to link to this page
Your browser does not support the video tag.