Laserfiche WebLink
� <br /> NMM-100P(A) Mini iNonitor Module Dimensions: 1.3°(3.302 cm)high x 2.75°(6.985 cm) wide x <br /> 0.65"(1.651 cm)deep. <br /> • Built-in rype identification automatically identifies this device <br /> as a monitor module to the panel. Wire length:6"(15.24 cm)minimum. <br /> � Powered directly by two-wire SLC loop.No additional power <br /> required NZM•100(A) Interface Module <br /> • High noise(EMF/RFI)immunity. • Supports compatibie lwo-wire smoke detectors. <br /> � Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power <br /> • Direct Decade entry of address: 01 -99 on FireWarden- source. <br /> 100-2,01 -50 on FireWarden-50 • High noise(EMF/RFI)immunity. <br /> _ __ _ _ � • SEMS screws with clamping plates for ease of wiring. <br /> m �5 o I ADDRESS o ' • Direct Decade entry of address, 01 -99 on FireWarden- <br /> 3 13���'��� Z � � \ 2 � 100-2,01 -50onFireWarden-50. <br /> 3 �Z' � 3I` L O O P � �' '�3 • LED flashes during normal operation. <br /> �� � � `�'� a • LED latches steady to indicate alarm on command from <br /> ��9���6 5, _._ 9���g 5 control panel. <br /> 8 � 8 � The NZM-100 A Interface Module is intended for use in intelli- <br /> TENS ONES � � <br /> �� _. ,,� � gent, addressabie systems, where the individual address of <br /> - � � '�'' each module is selected using built-in rotary switches. This <br /> ;; module allows intelligent panels to interface and monitor two- <br /> i wire conventional smoke detectors.It transmits the status(nor- <br /> �I ` F' � � mal,open,or alarm)oi one full zone of conventional detectors <br /> �� , �;,� W � U back to the control panel. All two-wire detectors being moni- <br /> �I � > � � m tored must be UL compatible with the module. <br /> j ;� NZM-100(A) APPLICATIONS <br /> � i Use the NZM-100(A) to monitor a zone of two-wire smoke <br /> detectors. The monitored circuit may be wired as an NFPA <br /> � I �� Style B(Class B)or Style D(Class A)Initiating Device Circuit. <br /> The NMM-100P(A) Mini Monitor Module can be instafled in a A 3.9 K ohm End-of-Line Resistor (provided) terminates the <br /> single-gang junction directly behind the monitored unit. Its end of the Style B or D (class B or A)circuit(maximum IDC <br /> small size and light weight allow it to be installed without rigid loop resistance is 25 ohms). Install ELR across terminals 8 <br /> mounting.The NMM-100P(A)is intended for use in intelligent, and 9 tor Sryle D application <br /> two-wire systems where the individual address of each module <br /> is selected using rotary switches. It provides a two-wire initiat- NZM-100(A)OPERATION <br /> ing device circuit for normally-open-contact fire alarm and Each NZM-100(A) uses one of the available module <br /> security devices. NMM-100P(A) addresses on an SLC loop. It responds to regular polis from <br /> NMM-100P(A)APPLICATlONS the control panel and reports its type and the status(open/nor- <br /> mal/short)of its Initiating Device Circuit(IDC).A flashing LED <br /> Use to monitor a single device or a zone of four-wire smoke indicates that the module is in communication with the control <br /> detectors,manual fire alarm pull stations,waterflow devices,or panel. The LED latches steady on alarm (subject to current <br /> other normally-open dry-contact devices. May also be used to limitations on the loop). <br /> monitor normatly-open supervisory devices with special super- <br /> visory indication at the control panel. Monitored circuiUdevice NZM-f00(A)SPECIFlCATIONS <br /> is wired as an NFPA Style B(Class B)Initiating Device Circuit. Nominal operating voltage: 15 to 32 VDC. <br /> A 47K ohm End-of-Line Resistor(provided)terminates the cir- <br /> cuit. Maximum current draw:5.1 mA(LED on). <br /> NMM-100P(A)OPERATION Maximum IDC wiring resistance:25 ohms. <br /> Each NMM-100P(A) uses one of the available module Average operating current: 300 uA, 1 communication and 1 <br /> addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. <br /> the control panel and reports its rype and the status(open/nor- EOL resistance:3.9K ohms <br /> mal/short)of its Initiating Device Circuit(IDC). External supply voltage (between Terminals T3 and T4): <br /> NMM-t 00P(A) SPECIFlCATJONS DC voltage: 24 volts power limited. Ripple voltage: 0 1 Vrms <br /> maximum.Current:90 mA per module maximum. <br /> Nominal operating voltage� 15 to 32 VDC. Temperature range:32°F to 120°F(0°C to 49°C) <br /> Average operating current: 350 vA, 1 communication every o , <br /> 5 seconds, 47k EOI, 600 NA Max. (Communicating, IDC Humidity range: 10/o to 93/o noncondensing. <br /> Shorted) Dlmensions: 4.5" (1143 cm) high x 4" (1016 cm) wide x <br /> Maximum IDC wiring resistance:40 ohms. 1•25" (3.175 cm) deep. Mounts to a 4" (10 16 cm) square x <br /> 2.125"(5.398 cm)deep box <br /> Maximum IDC Voltage: 11 Volts. <br /> Maximum IDC Current:400 uA. <br /> EOL resistance:47K ohms. <br /> Temperature range:32°F to 120°F(0°C to 49°C). <br /> Humidity range: 10%to 93%noncondensing. <br /> Page 2 014—DN-6999.0•1 010 6/2 0 1 0 <br />