DN-7097 C1
<br /> SpectrAlert� Advance ���.' � ' � �f7
<br /> Selectable Output �
<br /> Notification Appliances by Honeywell
<br /> �
<br /> General , - �.,
<br /> System Sensor0 SpectrAlerlO Advance selectable-output ' " �""•'�"'"-
<br /> horns,strobes and hom/strobes are rich with features guaran- � �, '=�� a +
<br /> teed to cut installation times and maximize profits. The Speo- ,�-�.�,�,?��)'� t �
<br /> trAlert Advance series of notification appliances is designed to ':�`''��a�:��.,•,o
<br /> simplity your installations, with features such as: plug-in Indoor Ceiling Outdoor Ceilingo
<br /> designs,instant feedback messages to ensure correct installa-
<br /> tion of individual devices, and eleven field-selectable candela HornlStrobe Strobe
<br /> settings for wall and ceiling strobes and horn/strobes.
<br /> More specifically, when installing Advance products, first :� �'
<br /> _i .� ,=:::�•,.=
<br /> attach a universal mounting plate to a four-inch square, four- �x ` � � a
<br /> inch octagon, or double-gang junction box. The two-wire i�' ° �
<br /> mounting plate attaches to a single-gang junction box. ,�s a ;;;,� �
<br /> ' =i`�":•;:' �. �`.
<br /> Then, connect the notification appliance circuit wiring to the "' �
<br /> SEMS terminals on the mounting plate. Indoor Wall Indoor Ceiling
<br /> Finally,attach the horn,strobe,or horn/strobe to the mounting HornlStrobe Strobe
<br /> plate by inserting the producYs tabs in the mounting plate's -
<br /> grooves. The device will rotate into position, locking the prod- `� ---
<br /> ucYs pins into the mounting plate's terminals. The device will ��" _ �
<br /> temporarily hold in place with a catch until it is secured with a _ _ a
<br /> captured mounting screw. „' '�
<br /> �;s, . �. , I`
<br /> SpectrAlert Advance products allow you to choose: r.= , ,,_;.- �o
<br /> • 12 or 24 volts. Indoor Wall Outdoor Wall n
<br /> • 15, 15l75,30,75,95, 110, 115, 135, 150, 177,or 185 can- Horn Strobe
<br /> dela by way of a rear-mounted slide switch and front view- • Outdoor products rated from-40°F and 151°F(-40°C and
<br /> ing window 66°C).
<br /> • Horn tones and volume by way of a rotary switch. • Outdoor products rainproof per UL50 (NEMA 3R) and
<br /> • The SpectrAlert Advance series includes outdoor notifica- Weatherproof per NEMA 4X,IP56
<br /> tion appliances. Outdoor strobes and horn/strobes (two- • Minimal intrusion into the backbox
<br /> wire and four-wire)are available for wall or ceiling.Outdoor • Horn rated at 88+dbA at 16 volts.
<br /> horns are available for wall only.All System Sensor outdoor . Rotary switch for tone selection.
<br /> products are rated between-40°F and 151°F (-40°C and . Three horn volume settings.
<br /> 66°C)in wet or dry applications.
<br /> Models available: • Electrically compatible with existing SpectrAlert products.
<br /> • Indoor wall-mount: horn, strobe, 2•wire horn/strobe, 4-wire Engineering Specifications
<br /> horn/strobe.
<br /> • Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire SpectrAlert Advance horns, strobes, and horn/strobes shall
<br /> horn/strobe. mount to a standard 4 0"x 4.0" x 1.5" (10.16 x 10.16 x 3.81
<br /> Outdoor wall-mount: horn, strobe, 2-wire horn/strobe, 4- cm)backbox,4.0"(10?6 cm)octagonal backbox,or a double-
<br /> • wire horn/strobe. gang backbox Two-wire products shall also mount to a single-
<br /> gang 2.0"x 4.0"x 1 875"(5.08 x 10 16 x 4 763 cm)backbox.A
<br /> • Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire universal mounting plate shall be used for mounting ceiling
<br /> horn/strobe. and wall products. The notification appliance circuit wiring
<br /> shall terminate at the universal mounting plate. Also, Spec-
<br /> Features trAlert Advance producis, when used with the Sync•Circuitr"'
<br /> Module accessory, shall be powered from a non-coded notifi-
<br /> • Plug-in design cation appliance circuit output and shall operate on a nominal
<br /> • Same mounting plate for wali-and ceiling•mount units. 12 or 24 volts. When used with the Sync•Circuit Module, 12-
<br /> • Shorting spring on mounting piate tor continuity check volt rated notification appliance circuit outputs shall operate
<br /> before installation be[ween 9 and 17,5 volts; 24-volt rated notification appliance
<br /> • Captive mounting screw. circuit outputs shall operate between 17 and 33 volts. Indoor
<br /> SpectrAlert Advance products shall operate between 32°F and
<br /> • Tamper-resistance capability. 120°F(0°C and 49°C)from a regulated DC,or full-wave-recti-
<br /> • Field-selectable candela settings on wall and ceiling units: fied, unfiltered power supply. Strobes and horn/strobes shall
<br /> 15, 15/75,30,75,95, 110, 1 15, 135, 150, 177, 185. have(ield-selectable candela settings including 15, 15/75, 30,
<br /> • Automatic selection of 12 or 24 volt operation at 15 and 15/ 75,95, 110, 115, 135, 150, 177, 185
<br /> 75 candela.
<br /> • Outdoor wall and ceiling products.
<br /> - - �
<br /> DN-7087:C1•11;9/I 1-Page 1 of 4