My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14769
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14769
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2014 10:01:10 AM
Creation date
7/28/2014 10:01:09 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
13-14769
Building Department - Name
LEITZKE,THOMAS
Address
6024 RIDGEWAY DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i 1 1 � <br /> c <br /> c � <br /> � <br /> ICC-ES Evaluation Report ESR-1601* <br /> Reissued September 1, 2012 <br /> This report is subject to renewal November 1, 2014. <br /> www.icc-es.orq � (800)423-6587 � (562)699-0543 A Subsidiary of the /niemational Code Council� <br /> DIVISION:07 00 00—THERMAL AND MOISTURE instructions. The manufacturers published installation <br /> PROTECTION instructions must be available at the jobsite at all times <br /> Section:07 30 05--Roofing Felt and Underiayment during installation. <br /> REPORT HOLDER: Prior to appliqtion of the underlayment, the roof deck <br /> surtace must be free of frost,dust and dirt,loose nails,and <br /> ALPHA PROTECH ENGINEERED PRODUCTS,INC. ather protrusions.Damaged sheathing must be replaced. <br /> 301 SOUTH BLANCHARD STREET Installation of an approved roof covering can proceed <br /> VALDOSTA,GEORGIA 31601 immediately following application of the roofing <br /> (229)242-1931 underlayment. The underlayment is to be covered by the <br /> www.alohaprotech.com roof covering within the time set forth in the underlayment <br /> manufacturers published installation instructions. For <br /> EVALUATION SUBJECT: reroofing appliptions, the same procedures apply after <br /> removal of the existing roof covering and roofing felts to <br /> REXTM' SYNFELT, REXTREME AND TECHNOPLY expose the roof dedc. <br /> SYNTHETIC ROOF UNDERLAYMENTS 4.2 Applications: <br /> 1.0 EVALUATION SCOPE The underlayment must be installed in accordance with <br /> Compliance with the following codes: Chapter 15 of the IBC or Chapter 9 of the IRC, and must <br /> be laid printed side up horizontally (parallel to the eave) <br /> ■ 2012,2009 and 20061nfemationa!Building Code�(IBC) starting at the lower edge of the roof, with 3-inch(76 mm) <br /> ■ 2012,2009 and 2006/nfemationa!Residenfial Code� horizontal (head) laps and 6-inch (152 mm) vertical (end) <br /> (IRC) laps. <br /> Prope�ties evaluated: The underlayment must be fastened to the roof deck <br /> ■ Physical properties using minimum No. 12 gage [0.109-inch (2.77 mm)] <br /> minimum shank diameter, coROSion-resistant roofing nails <br /> ■ Fire classification having minimum 1-inch-diameter (25.4 mm) plastic caps. <br /> 2.0 USES The fasteners must be spaced 8 inches (203 mm) on <br /> center at vertical and hor¢ontal laps, and 24 inc�es <br /> REX�" SynFelt, REXtreme and TECHNOpIy synthetic (610 mm) on center vertically and horizontally in a <br /> roofing underlayments are altematives to the ASTM D226, staggered pattern in the field of the underlayment, except <br /> Type I and Type II, roofing underlayment specified in in areas subject to high winds where underlayment <br /> Chapter 15 of the IBC and Chapter 9 of the IRC. The fastening must comply with high wind attachment <br /> underlayments are also used as components of classified requirements specified in IBC Section 1507 or IRC Section <br /> roofing assemblies when installed as described in this R905. Fasteners must be long enough to penetrate into the <br /> report. sheathing a minimum of 3/4 inch (19.i mm) or through the <br /> 3.0 DESCRIPTION sheathing, whichever is less. When battens are installed <br /> over the unde�layment, the undeMayment need only be <br /> The roof underlayments consist of a woven polypropylene preliminarily attached pending attachment of the battens or <br /> fabric with a polypropylene coating on each side. The countefiattens. <br /> REXTM' SynFelt, REXtreme and TECHNOpIy synthetic <br /> underlayments have nominal weights, respedively, of 2.56 A single layer of minimum 24-inch-wide (610 mm) <br /> pounds per 100 square feet (125 g/m2), 2.97 pounds per underlayment must be installed and centered vertically at <br /> 100 square feet (145 g/mZ), and 2.05 pounds per 100 all valleys before underlayment in the field, and at atl hips <br /> square fest(100 g/m2),and are produced in rolls of various and ridges after underlayment in the field. <br /> sizes. Where the slope is from 2:12(17 percent slope)up to 4.12 <br /> 4.0 DESIGN AND INSTALLATION (33 percent slope) and the roof is to be covered with <br /> 4.1 General: asphalt shingles, or where the slope is from 2�/Z.12 <br /> (21 percent slope) up to 4:12 (33 percent slope) and the <br /> Installation must comply with the applicable code, this roof is to be covered with concrete or Gay roof 61es, the <br /> report and the manufacturer's published installation underlayment must be horizontally lapped 24 inches <br /> 'Revised November 2012 <br /> lCGES Evaluanon Reports are nor to be construed as represen(rng aesthetics or arry olher attrrbwes nof specifically addresse�l rwr are rhey 1n be cansirued � <br /> as an endorsemen!of the svbject of the report or a recommenalation for its use.There is no warranry by ICC Evalualion Service,LLC,etpress or impliecl,as � <br /> ro orry findrng or other marrer in this report,or as to any praiacr covered by�he nport. �� � <br /> COpyright�2012 Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.