Laserfiche WebLink
ESR-1601 I Most�dely Accepted and Trusted Page 2 of 2 <br /> (610 mm)to the centeriine of the underlying course to form codes listed in Section 1 0 of this report, subject to the <br /> two layers with 6-inch (152 mm) vertical laps. Seams in following conditions: <br /> laps must be sealed with adhesives complying with ASTM 5.7 Installation must comply with this report and the <br /> D4586,Type 1.Subsequent courses of underlayment must manufacturer's published installation instructions, and <br /> be installed parallel to the eave, from the lower edge me applicable code. In the event of conflict between <br /> upwards to the ridge, in a shingle manner The �e published installation instructions and this report, <br /> underlayment must be mechanically fastened as specified the more restrictive must govem. <br /> in Section 4.2. <br /> 4.3 Ice BarNer: 5.2 Installation must be limited to roofs with a minimum <br /> slope of 2:12 (17 percent slope) or to the minimum <br /> In areas of the roof required to have an ice barrier under slope required for the roof covering in accordance <br /> Chapter 15 of the IBC or Chapter 9 of the IRC, two layers with the applicable code,whichever is greater <br /> of the underlayment must be cemented together with a <br /> roofing cement complying with ASTM D4586, for a 5.3 Installation must be limited to use with roof coverings <br /> minimum distance of 24 inches (610 mm) inside the that do not involve hot asphalt or coal-tar pitch. <br /> exterior wall line of the building. The roof underlayment, in 5.4 Installation must be limited to solid substrates <br /> the field of the roof,must overlap the ice barrier complying with the applicable code. <br /> 4.4 Flashing: 5.5 Installation must be limited to use with approved roof <br /> Flashing must be in accordance with the applicable code. coverings that are mechanicatly fastened through the <br /> Flashing around protrusions must be over the lower course underlayment to the sheathing or rafters, or to use <br /> of the underlayment and under the upper course of the with approved roof coverings that are mechanically <br /> underlayment,to prevent water badcup.When used,metal fastened to battens or counterbattens that are <br /> drip edges must be installed beneath the underlayment at mechanically fastened through the underlayment to <br /> the eaves and over the underlayment at rakes. the sheathing or rafters. <br /> 4.5 Classified Roofs: 5.6 Installation must be limited to roofs with ventilated <br /> Under the 2012 and 2009 IBC and IRC, the roofing attic spaces in accordance with the requirements of <br /> underlayments may be used as components of Gassified the applicable code. <br /> roof assemblies consisting of Class A or C glass fiber mat 5.7 The products are manufactured in Valdosta, Georgia, <br /> shingle or Class C asphalt organic felt shingle complying under a qualiry control program with inspections by <br /> with the applicable code,when ins talled in accordance with R,qDCO(AA-650). <br /> this report over a minimum /�-inch-thidc (11.9 mm) <br /> plywood deck. 6.0 EVIDENCE SUBMITTED <br /> Under the 2006 IBC, the underlayment may be used in 6.1 Data in accordance with the ICC-ES Acceptance <br /> Class A or Class B roof assemblies that utilize the roof Criteria for Roof Underlayments (AC188), dated <br /> coverings specified in the excep6on to Sections 1505.2 February 2012. <br /> and 1505.3. Under the 2006 IRC, the underlayment may <br /> be used with roof coverings of bridc, masonry, slate, Gay 6.2 Report of testing in accordance with ASTM E108 <br /> or concrete roof tile, concrete roof deck, ferrous or copper (UL 790). <br /> shingles or sheets, and metal sheets and shingles where 7,0 IDENTIFICATION <br /> such roof coverings are permitted to be used in lieu of a <br /> Class A assembly under Section R902.1 Each roll of the product described in this report must be <br /> 5.0 CONDITIONS OF USE marked with the manufacturer's name (Alpha ProTech <br /> Engineered Products, Inc.) and address, the product <br /> The REXTM' SynFelt, REXtreme and TECHNOpIy synthetic name, the date of manufacture, the evaluation report <br /> roof underlayments described in this report comply with,or number (ESR-1601), and the name of the inspection <br /> are suitable altematives to what is specified in, those agency(RADCO). <br />