Laserfiche WebLink
�' CO Fire Suppression <br /> � & Bui/din Products <br /> 9 <br /> Technical Services 800-381-9312�+1-401-781-8220 <br /> www.tyco-fire.com <br /> Model CV-iFR <br /> Riser Check Valves <br /> 2 to 12 Inch (DN50 to DN300) <br /> General � <br /> . . Never remove any piping component <br /> Descr�pt�on nor correct or modify any piping defi- .�;;� <br /> The TYCO Modei CV-1 FR Riser Check ciencies without first de-pressurizing -� ,� <br /> and draining the system. Failure to do <br /> Valve is a compact and rugged swing- so may result in serious personal injury, <br /> type unit that allows water flow in one property damage,and/or impaired de- <br /> direction and prevents flow in the op- vice performance. '` <br /> posite direction.A resilient elastomer <br /> seal facing on the spring-loaded clap- The Model CV-1FR Riser Check Ualve <br /> per ensures a leak-tight seal and non- described herein must be installed and <br /> sticking operation.The Model CV-1 FR mainfained in compliance wifh this <br /> Check Valves are designed to minimize document and with the applicable stan- . <br /> water hammer caused by flow reversal. dards of the National Fire Protection •�- <br /> Association, in addition to the stan- <br /> The Model CV-1 FR Riser Check Valve dards of any authorities having juris- <br /> is furnished with grooved ends and can diction.Failure to do so may impair the <br /> be installed using GRINNELLGrooved performance of this device. �nstallation <br /> Couplings or GRINNELL Figure 71 <br /> Flange Adapters. The Model CV-1 FR Owners are responsible for maintain- The Model CV-1 FR Riser Check Valves <br /> Valves have been designed with a ing their fire protection system and are to be installed in accordance with <br /> removable cover for ease of field main- devices in proper operating condition, the following instructions: <br /> tenance.These valves can be installed The installing contractor or manufac- <br /> horizontally(with cover in the upward turer should be contacted wifh any 1.The arrow cast on the Body must <br /> position)or vertically with the flow in the questions. point in the direction of the flow. <br /> upward direction.Refer to Figure 6. 2.Valves installed vertically must be <br /> To facilitate their use in wet-type auto- /echnical positioned with the flow in the up- <br /> matic sprinkler system risers,the Model ward direction. <br /> CV-iFR Riser Check Valves are provid- �ata 3.Valves installed horizontally must be <br /> ed with threaded outlets for pressure positioned with the Cover facing up. <br /> gauges and a drain connection.They Approvals Refer to Figure 6. <br /> provide a more compact and economi- UL,C-UL,and FM <br /> cal alternative to an alarm check valve 4.Grooved end pipe couplings used <br /> where a water motor alarm is not re- Sizes with the Model CV-1FR Riser <br /> quired. Provisions must be made for 2 to 12 Inch(DN50 to DN300) Check Valve must be installed in <br /> a local alarm using an approved flow accordance with manufacturer's <br /> Maximum Working Pressure instructions. <br /> switch(not included). 300 psi(20,7 bar) <br /> The Model CV-1 FR Riser Check Valve is Valve Assembly Finish <br /> also Listed for use in conjunction with Red, non-lead paint <br /> the TYCO Model DV-5 Deluge Valve in <br /> Preaction Systems under air pressure <br /> without the use of prime water. <br /> The Model CV-1 FR Riser Check Valves <br /> are a redesign for the Central Figure <br /> 590FR and GRINNELL Figure 590FR. <br /> Page 1 of 6 OCTOBER 2010 TFP950 <br />