Laserfiche WebLink
Rhvac-Residentlal&Light Commerclal HVAC Loads Elite Sottware Development,inc. <br /> HVAC Designs WalnutGrove TH 1129 N <br /> Tam a,FL 33615 Pa e 6 <br /> Total Buildin Summa Loads <br /> Component Area Sen Lat Sen Total <br /> Deccri tion Quan Loss Gain Gain Gain <br /> OP LOW E MIN:Gluing•NFRC CODE MIN Operable 2 45.2 723 0 565 565 <br /> Pane Low E,ground reflectance=0.23,outdoor <br /> insect screen with 50%coverage,light color blinds <br /> at 45°with 100°/.coverage,u-value 0.5,SHGC 0.5 <br /> FD LOW E MIN:Glazing-NFRC CODE MIN Glass Door 2 20 320 0 278 278 <br /> Pane low E,ground reflectance=0.23,light color <br /> bUnds at 45°with 100°/.coverage,u-value 0.5, <br /> SHGC 0.5 <br /> 11 N:Door-Metal-Polystyrene Core 40 434 0 343 343 <br /> 12B-0sw:Part-Frame,R-11 insulation in 2 x 4 stud 194.6 567 0 377 377 <br /> cavity,no board insulation,siding finish,wood <br /> studs <br /> 13A-4ocs:Wall-=1ock,board insulatlon only,R-4 board 296.2 1,356 0 775 775 <br /> insulation,open core,siding fnish <br /> 13A-4ocs:Part•Block,board insulation only,R-4 board 92 395 0 263 263 <br /> insulation,open core,siding finish <br /> 168-30-ad:RooflCeiling-Under Attic with Insulation on 1129.3 1,157 0 1,915 1,915 <br /> Attic Fioor(also use for Knee Wall and Partition <br /> Ceilings),vented attic,no radiant barrier,R-30 <br /> insulation,dark asphalt <br /> 22A-pm:Floor-Slab on grade,No edge insulation,no 86 3,247 0 0 0 <br /> insulation below floor,any floor cover,passive, <br /> heavy dry or light wet soil <br /> ---- -_ __ ---- _- -- ---- ------ -- -- --- -- <br /> Subtotals for structure: 8,199 0 4,516 4,516 <br /> People: 3 690 900 1,590 <br /> Equipment: 640 2,040 2,680 <br /> Lightfng: 0 0 0 <br /> Ductwork: 1,646 272 1,422 1,694 <br /> InNltration:Wlnter CFM:105,Summer CFM:54 3,707 1,588 1,072 2,660 <br /> VentilaGon:Wmter CFM 0 Summer CFM 0 0. _0 0 0 <br /> _. _........_ �......... __..._. __ _ _ _. __ _ <br /> Total Building Load Totalc: 13,552 3,190 9,950 13,140 <br /> Check Fi ures <br /> Total Building Supply CFM: 600 CFM Per Square ft.: 0.531 <br /> Square ft.of Room Area: 1,129 Square ft.Per Ton: 1,021 <br /> Volume(ft')of Cond.Space: 9,034 <br /> Buildin Loads <br /> Total Heating Required Inciuding Ventflation Air: 13,552 Btuh 13.552 MBH <br /> Total Sensible Galn: 9,950 Btuh 76 % <br /> Total Latent Gain: 3,190 Btuh 24 % <br /> Total Cooling Required Including Ventilation Air: 13,140 Btuh 1.11 Tons(Based On 75%Sensible Capacity) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D. <br /> All omputed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both senslble and latent loads according to the manufacturer's performance data at your design conditions. <br /> Monday,November 04,2013,12:09 PM <br />