Rhvac-Res(dential&Light Commerctal HVAC Loads Elite Software Development,lnc. <br /> HVAC Designs Wa/nut Grove TH 1129 N <br /> Ta a,FL 33615 Pa e 7 <br /> S stem 1 Room Load Summa <br /> Htg Min Run Run Clg Clg Min Act <br /> Room Area Sens Htg Duct Duct Sens Lat Clg Sys <br /> No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM <br /> –Zone 1— <br /> Foyer 50 2,381 54 4 • 930 133 47 56 <br /> 3 Bed 2 156 3,112 71 5 - 1,317 339 67 79 <br /> 4 Bath 2 54 64 1 4 - 177 60 9 11 <br /> 5 Kitchen 204 802 18 6 - 2,188 500 111 132 <br /> 6 Bath 1 127 146 3 4 • 345 80 17 21 <br /> 7 Great 276 3,022 69 6,6 • 3,259 1,129 165 197 <br /> 8 M Wic 45 52 1 4 • 89 0 4 5 <br /> _ 9.. M Bed _._ _ 217 3,970_ 90 __ 6 • _ 1645 _ 677 83 99 <br /> .... .._. .._..._. _....... _. .1......_...._.. . ......_... .__... ____.......___ <br /> _...._.....Duct_latent ..... _...__ _ _ __.__ . ......__ _272 <br /> _._ _.___... _....._ _...__. __._.. <br /> __ System 1 total_. 1,129 13,552... 308 ....._ _ ____9,950 3190 503 600 <br /> _ _ __. . _.... . �.. _...._.. _ _..._.... <br /> System 1 Main Trunk Size: 10x13 in. <br /> Velocity: 664 ft.lmin <br /> Loss per 100 ft.: 0.085 in.wg <br /> Duct size results above are ftom Manual D Ductsize. <br /> Runout dud velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize <br /> report for duct velocities and other data. <br /> Cooling System Summary <br /> Cooling SensiblelLatent Sensibie Latent Total <br /> Tons S lit Btuh Btuh Btuh <br /> Recommended �,�� 75%125% 9,950 3,317 13,267 <br /> Actual: 1.55 75°/.125% 13,950 4,650 18,600 <br /> E ui ment Data <br /> Heatina Svstem Cooling Svstem <br /> Type: Air Source Heat Pump Air Source Heat Pump <br /> Model: 4A6H3018C1 4A6H3018C1 <br /> Indoor Model: GAF2AOA18S11+TDR <br /> Brand: HERITAGE 13 HERITAGE 13 <br /> Description: Air Source Heat Pump Air Source Heat Pump <br /> Efficlency: 8.2 HSPF 14 SEER <br /> Comment: 0 <br /> Sound: 0 0 <br /> Capacity: 17,600 Btuh 18,600 Btuh <br /> Sensible Capacity: nla 13,950 Btuh <br /> Latent Capacity: nla 4,650 Btuh <br /> AHRI Reference No.: nla 4941299 <br /> This system's equipment was selected in accordance with ACCA Manual S. <br /> Manual S equipment sizing data: SODB:93F,SOWB:T7F,WODB:40F,SIDB:75F,SIRH:55%,WID6:72F,Sen.gain:9,950 B�h,Lat gain:3,190 Btuh, <br /> Sen.loss:13,552 Btuh,Entering clg.coil DB:75F,Entering clg.coil WB:63.9F,Entering htg.coil DB:72F,Clg.coil TD:18F,Htg.coil TD:40F,Req. <br /> clg.airflow:503 CFM,Req.htg.airflow:308 CFM <br /> Monday,November 04,2013,12:09 PM <br />