Laserfiche WebLink
� <br /> � <br /> 5. Interior of this tent follows the diagram provided above and meets all aisle width, exit width, aisle �� <br /> placement and an•angement criterion as noted at NFPA 1, Section 65.11.4.8.1, 65.11.4.8.1.2, <br /> 65.11.4.8.5, 65.11.3.14.3.1.1 through 65.11.3.14.3.1.4.There are no dead-end aisles. <br /> 6. • This facility is equipped with two emergency/exit light sets per NFPA 1, Section 65.11.4.8.3 and <br /> 65.11.4.8.4.IIours of operation are suggested as from 9:00 AM tlu-ough 12:00 A1V1.This varies as <br /> ii geis closer io the hoiiciay saies event. <br /> 7. All battery�perated equipment, electric�l equipment, and electrical cords in this facility are used <br /> in accordance with their listing per I�TFPA 1, Section 65.11.�.9.1. <br /> 8. All temporaiy wiring in the tent sh111 comply with NrPA 70 (2005 Ed.)article 590"Temporary <br /> Wiring"and shall be secured to prevent damage caused by civilian or vehicular traffic per NFPA <br /> l, Section 65.11.4.9.1.1. <br /> 9. Generators (if applicable)used at this location operates on a Class II or Class III combustible <br /> fuel. Specifically any generator utilized at this location operates on diesel fuel. <br />