My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
14-15548
Zephyrhills
>
Building Department
>
Permits
>
2014
>
14-15548
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2015 7:59:47 AM
Creation date
8/19/2015 7:59:38 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
14-15548
Building Department - Name
KENNEDY,ADAM & ABIGAIL
Address
39027 PARK DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
���"�s' <br /> �`,.' IsRINll1�I ERD <br /> 5.6 For mechanically attached insulation or embrane or strip-bonded insulation, the maximum <br /> design pressure for the selected assembl shall meet or exceed the Zone 1 design pressure <br /> determined in accordance with FBC Chap er 16. Zones 2 and 3 shall employ an attachment <br /> density designed by a qualified design rofessional to resist the elevated pressure criteria, <br /> Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* <br /> carry the limitations set forth in Secti n 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 <br /> enhancements. <br /> 5.7 For fully-adhered insulation, the maximum design pressure for the selected assembly shall meet <br /> or exceed critical design pressure determi ed in accordance with FBC Chapter 16. No rational <br /> analysis is permitted for these systems <br /> 5.8 For mechanically attached insulation or m mbrane over existing roof decks, fasteners shall be <br />� tested in the existing deck for withdrawal r sistance. A qualified design professional shall review <br /> the data for comparison to the minimum re uirements for the system. Testing and analysis shall <br /> be in accordance with TAS 105 or ANSI/SP I FX-1. <br /> 5.9 For bonded insulation or membrane over existing substrates in a re-roof (tear of� or recover <br /> installation, the existing deck or existing ro f surface shall be examined for compatibility with the <br /> adhesive to be installed. If any surface conditions exist that bring system performance into <br />� - 124 shall be <br /> uestion field u lift testin in accordance with ASTM E907 FM LPDS 1 52 or TAS <br /> q , P 9 , <br /> conducted on mock-ups of the proposed ne roof assembly. <br /> 5.10 For bonded insulation or membrane over e isting substrates in a recover installation, the existing <br /> roof system shall be capable of resistin project design pressures on its own merit to the <br /> satisfaction of the AHJ, as documented thr ugh field uplift testing in accordance with ASTM E907, <br /> FM LPDS 1-52 or TAS 124. <br /> 5.11 Metal edge attachment (except gutters), shall be designed and installed for wind loads in <br /> accordance with FBC Chapter 16 and teste for resistance in accordance with ANSI/SPRI ES-1 or <br /> RAS ili, except the basic wind speed shal be determined from FBC Figure 1609. <br /> 5.12 All products in the roof assembly shall ha e quality assurance audit in accordance with the FBC <br /> and F.A.C. Rule 61G20-3. <br /> 6. INSTALLATION: <br /> 6.1 GAF Modified Bitumen Roof Systems sh II be installed in accordance with GAF's published <br /> installation instructions, subject to the Lim tations/ Conditions of Use noted herein. <br /> 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" _ <br /> Maximum Design Pressure is the result o testing for wind load resistance based on allowable <br /> wind loads, and reflects the ultimate pass ng pressure divided by 2 (the 2 to 1 margin of safety <br /> per FBC 1504.9 has already been applie ). Refer to FBC 1609.1.5 for determination of design <br /> wind loads. <br /> 7. BUILDING PERMIT REQUIREMENTS: <br /> As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the <br /> installation of this product. <br /> 8. MANUFACTURING PLANTS: <br /> Contact the named QA entity for manufactu ing facilities covered by F.A.C. Rule 61G20-3 QA <br /> requirements. <br /> 9. QUALITY/ASSURANCE ENTITY: <br />� UL, LLC — QUA9625; (847) 664-3281 <br /> - THE 61-PAGES THAT FOLLOW FORM ART OF THIS EVALUATION REPORT- <br /> Exterior Research and Design, LLC. Evaluation Report 01506.11.04-R12 <br /> Certificate ofAuthorization#9503 FL5680-R12 <br /> Revision 12: 04/25/2014 <br /> Page 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.