<br /> �'`�-.�l TRINSTY�ERD
<br /> APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
<br /> Table Deck Application Type Description Page
<br /> lA Wood New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 4
<br /> 16-1 Wood New,Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4-5
<br /> 1B-2 Wood New,Reroof(Tear-Off),Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5
<br /> iC Wood New,Reroof(Tear-Off),Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 6
<br /> iD Wood New,Reroof(Tear-Off),Recover C Mech.Attached Insulation,Bonded Roof Cover 6
<br /> lE Wood New,Reroof(Tear-Off),Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 7
<br /> SF-1 Wood New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 8
<br /> 1F-2 Wood New,Reroof(Tear-Off),Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 9
<br /> 2A-1 Steel or Conc. New,Reroof(Tear-Off),Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 10-14
<br /> 2A-2 Steel or Conc. New,Reroof(Tear-Off),Recover B-2 Mech.Attached Thermal Barrier,Bonded Temp Roof,Bonded Insulation,Bonded Roof Cover 15
<br /> 28-1 Steel or Conc. New,Reroof(Tear-Off),Recover C Mech.Attached Insulation,Bonded Roof Cover 16-24
<br /> 28-2 Steel or Conc. New,Reroof(Tear-Off),Recover C-1 Bonded and Mech.Attached Insulation,Bonded Roof Cover 25
<br /> 2C Steel or Conc. New,Reroof(Tear-Off),Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 24-28
<br />- �n-+ � �,� niAU, Rornnf�"�eqr-(lff� a-1 Bonded Insulation Bonded Roof Cover(Base Insulation Layer Only) 28-30
<br /> 3A-2 Concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover(Base and Top Insulation Layers) 30-38
<br /> 3A-3 Concrete New,Reroof(Tear-Off) A-la Bonded Temp Roof,Bonded Insulation,Bonded Roof Cover 38-40
<br /> 3B Concrete New,Reroof(Tear-Off) F Non-Insuiated,Bonded Roof Cover 41
<br /> 4A LWIC New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 41-43
<br /> 4B LWIC New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 43-45
<br /> 4C LWIC New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 45
<br /> 5A CWF New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 46 ,
<br /> 56 CWF New,Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 47
<br /> SC CWF New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 48 li
<br /> 6A Gypsum Reroof(Tear-Of� A-1 Bonded Insulation,Bonded Roof Cover 49
<br /> 6B Gypsum Reroof(Tear-Oft� A-2 Mech.Attached Anchor Sheet,Bonded Insulation, Bonded Roof Cover 49
<br /> 6C Gypsum Reroof(Tear-Of� C Mech.Attached Insulation,8onded Roof Cover 49
<br /> 6D Gypsum Reroof(Tear-Of� E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 50
<br /> 7A-1 Various Recover A-1 Bonded Insulation,Bonded Roof Cover(Base Insulation Layer Only) 50-54
<br /> 7A-2 Various Recover A-1 Bonded Insulation,Bonded Roof Cover(Base and Top Insulation Layers) 54-61
<br /> Exterior Research and Design,LLC.d/b/a Trinity�ERD Evaluation Report 01506.11.04-R12 for FL5680-R12
<br /> Certificate of Authorization#9503 Revision 12:04/25/2014
<br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 1 of 61