Laserfiche WebLink
� '`��' . <br /> �``�..f ��I����ERD <br /> The followina notes apolv to the svstems outlined herein: <br /> 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the <br /> satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. <br /> 2. Unless otherwise noted, fasteners and stress plates for insulation or base sheet attachment shall be as follows. Fasteners shall be of sufFicient length for the following <br /> engagements: <br /> ➢ Wood: Drill-Tec#12 Fastener or Drill-Tec#14 Fastener with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec Accutrec Plate,Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP Roofing <br /> Fastener Assembled with a 3"Metal Plate. Minimum 0.75-inch plywood penetretion or minimum 1-inch wood plank embedment. <br /> ➢ Steel: Drill-Tec#12 Fastener,Drill-Tec#14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec Accutrac Plate;Drill-Tec ASAP 3S;Drill-Tec <br /> Heavy Duty ASAP Roofing Fastener Assembled with a 3"Metal Plate;Drill-Tec Extre Heavy Duty ASAP Roofing Fastener-Insulation. Minimum 0.75-inch steel pe�etration and engage the top <br /> flute of the steel deck. <br /> ➢ Concrete: Drill-Tec#14 Fastener or Drill-Tec CD-10 with Drill-Tec 3"Standard Steel Plate,Drill-Tec 3"Steel Plate or Drill-Tec Accutrec Plate or Drill-Tec Heavy Duty ASAP Roofing Fastener Assembled with <br /> a 3"Metal Plate. Minimum 1-inch embedment into pilot hole in accordance with the fastener manufacturer's pu6lished installation instructions. <br /> 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, DensDeck, DensDeck Prime, DensDeck <br /> DuraGuard, MonoBoard, TopRock DD, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board that meets the QA requirements of F.A.C. Rule 61G20-3 <br /> and is documented as meeting FBC 1505.1 and,for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover. VersaShieldp Solo•"' Fire-Resistant Slip Sheet <br /> may be used as a non-load-bearing,fire-barrier slip-sheet component within any system outlined herein. <br /> 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, <br /> bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal <br /> or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the <br /> AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. <br /> 5. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in <br /> e manu ac ur . <br /> ➢ Hot asphalt(HA): Full coverege at 25-30 Ibs/square <br /> ➢ OMG OlyBond 500(OB500): Continuous 0.75-inch wide ribbons, 12-inch o.c. using PaceCart or SpotShot. Note: OlyBond C/ossic or OlyBond 500 Green may be used <br /> where O/y8ond 500 is referenced. <br /> ➢ GAF LRF Adhesive M(LRF-M): Continuous 1-inch wide ribbons,12-inch o.c <br /> ➢ ADCO Millennium One-Step Foamable Adhesive(M-OSFA): Continuous 1-inch wide ribbons,12-inch o.c. <br /> ➢ GAF 2-Part Roofing Adhesive(GAF 2-Part): Continuous 2.5 to 3-inch wide ribbons,12-inch o.c. <br /> ➢ 3M CR-20: Continuous 2.5 to 3-inch wide ribbons,12-inch o.c. Note:TITESET may be used where 3M CR-20 is referenced. <br /> ➢ Note: When multiple layers(sJ of insulation and/or coverboard are installed in ribbon-applied adhesive,adhesive ribbons shall be staggered from/ayer-to-layer a distance of one-ha/f the ribbon spacing. <br /> ➢ Note: The maximum edge distance from the adhesive ribbon to tfle edge of the insu/otion board shall be not less than one-half the specified ribbons spacing. <br /> 6. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be <br /> substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to�increase'the MDP listings in the tables; rather if MDP <br /> listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker <br /> material listed in the table. <br /> ➢ Hot asphalt(HA): MDP -240.0 psf (Min.0.5-inch thick) <br /> ➢ OMG OlyBOnd 500(OB500): MDP -315.0 psf (Min.0.5-inch thick EnergyGuard RH or RN) <br /> ➢ OMG OlyBond 500(OB500): MDP -485.0 psf (Min.0.5-inch thick EnergyGuard RA) <br /> ➢ GAF 2-Part Roofing Adhesive(GAF 2-Part): MDP -117.5 psf (Min.1.0-inch thick) <br /> ➢ 3M CR-20: MDP -117.5 psf (Min.1.0-inch thick) <br /> 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. <br /> 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design <br /> pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the <br /> Exterior Research and Design,LLC.d/b/a Trinity�ERD Evaluation Report 01506.11.04-R12 for FL5680-R12 <br /> Certificate of Authorization#9503 Revision 12: 04/25/2014 <br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 2 of 61 <br />