Laserfiche WebLink
�I � - <br /> �.�r� � <br /> �`S_��a$�NIN 1 ERD <br /> � <br /> TABLE 2A-1: STEEL OR CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TeaR-OFF)oR RECOVER <br /> SYSTENI TYPE B-1: NIECHANICALLY ATTACHED BASE INSULATIOIV,BONDED TOP INSULATION,BONDED ROOF COVER <br /> System Deck Base Insulation Layer Top Insulation Layer Roof Cover MDP <br /> Na• (See Note 1) Type Fasten Attach Type Attach Base Ply Cap �PS� <br /> Min.22 ga.,type B, Min.2-inch SBS-AA <br /> SC-li Grade 33 steel or EnergyGuard RA, See Note 1 per Min. 1.0-inch EnergyGuard Perlite Roof HA BP-AA, (Optional)BP- or SBS- -60.0 <br /> structural concrete EnergyGuard RH, 2 1.45 ft2 Insulation(homogeneous) SBS-AA AA,SBS-AA TA <br /> EnergyGuard RN <br /> Min.2-inch <br /> Min.22 ga.,type B, EnergyGuard RA, See Note 1 per Min.0.5-inch Structodek High Density BP-AA, (Optional)BP- SBS-AA <br /> SC-12 Grede 33 steel or EnergyGuard RH, 2 1.45 ft2 Fiberboard Roof Insulation HA SBS-AA AA,SBS-AA or SBS- -67.5 <br /> structural concrete EnergyGuard RN TA <br /> (Optional) <br /> Min. 1.5-inch Optional additional layers of base HA,GAF BP-AA, SBS-AA, <br /> Min.22 ga.,type B, One or more <br /> EnergyGuard RA, See Note 1 per 2 insulation; Min.0.25-inch DensDeck, 2-Part, SBS-AA, SBS-TA * <br /> SC-13 Grade 33 steel or BP-AA,SBS- -45.0 <br /> EnergyGuard RH, 2 ft2 DensDeck Prime or SECUROCK Gypsum- CR-20, SBS-TA or or APP- <br /> structural concrete EnergyGuard RN Fiber Roof Board OB500 APP-TA AA,SBS-TA or TA <br /> APP-TA <br /> (Optional) <br /> Min.2-inch Optional additional layers of base HA,GAF BP-AA, SBS-AA, <br /> Min.22 ga.,type B, One or more <br /> SC-14 Grede 33 steel or EnergyGuard RA, See Note 1 per insulation; Min.0.25-inch DensDeck, 2-Part, SBS-AA, SBS-TA * <br /> BP-AA,SBS- -45.0 <br /> EnergyGuard RH, 2 4.0 ft2 DensDeck Prime or SECUROCK Gypsum- CR-20, SBS-TA or or APP- <br /> structurel concrete EnergyGuard RN Fiber Roof Board OB500 APP-TA AA,SBS-TA or TA <br /> APP-TA <br /> Min. 1.5-inch HA,GAF <br /> Min.22 ga.,type B, EnergyGuard RA, See Note 1 per 2 Min. 0.5-inch EnergyGuard High Density 2-Part, BP-AA, * <br /> SC-15 Grade 33 steel or EnergyGuard RH, z ft2 Roof Fiberboard CR-20 or SBS-AA None SBS-CA -45.0 <br /> structural concrete EnergyGuard RN or OB500 <br /> EnergyGuard Ultra <br /> (Optional) <br /> Min.22 ga.,type B, Min.2-inch HA,GAF BP-AA, SBS-AA, <br /> EnergyGuard RA, See Note 1 per 2 Min.0.375-inch SECUROCK Gypsum-Fiber 2-Part, SBS-AA, One or more SBS-TA <br /> SC-16 Grade 33 steel or BP-AA,SBS- -60.0 <br /> EnergyGuard RH, 2 ft2 Roof Board CR-20, SBS-TA or or APP- <br /> structural concrete EnergyGuard RN OBS00 APP-TA ��SBS-TA or TA <br /> APP-TA <br /> (Optfonal) <br /> Min.2-inch HA' BP-AA, SBS-AA, <br /> Min.22 ga.,type B, 0B500 or One or more SBS-TA <br /> EnergyGuard RA, See Note 1 per Min.0.25-inch SECUROCK Gypsum-Fiber SBS-AA, <br /> SC-17 Grade 33 steel or GAF 2- BP-AA,SBS- -60.0 <br /> structurel concrete EnergyGuard RH, 2 1.6 ft2 Roof Board Part,CR- SBS-TA or qA,SBS-TA or or APP- <br /> EnergyGuard RN Z� APP-TA APP_TA TA <br /> SELF-ADHERING SYSTEMS7 <br /> Min.22 ga.,Type Min.0.5-inch EnergyGuard RH HD Polyiso OB500, SBS-SA or (Optional) <br /> B,Grede 33 steel Min. 1.5-EnergyGuard See Note 1 per 2 Insulation,EnergyGuard HD Polyiso SBS-TA, * <br /> SC-18 or structurel RH 2 ftZ Insulation,EnergyGuard HD Plus Polyiso LRF-M,M- Weather- SBS-TA,APP- APP-TA -37.5 <br /> concrete Insulation OSFA Watch XT TA <br /> Min.22 ga.,Type Min.0.5-inch EnergyGuard RH HD Polyiso pg500, SBS-SA or (Optional) <br /> B,Grade 33 steel Min.2-EnergyGuard See Note 1 per Insulation,EnergyGuard HD Polyiso SBS-TA, * <br /> SC-19 or structurel RH 2 2.9 ftZ Insulation,EnergyGuard HD Plus Polyiso LRF-M,M- Weather- SBS-TA,APP- APP-TA '37.5 <br /> concrete Insulation OSFA Watch XT TA <br /> Exterior Research and Design,LLC.d/b/a Trinity�ERD Evaluation Report 01506.11.04-R12 for FL5680-R12 <br /> Certificate of Authorization#9503 Revision 12: 04/25/2014 <br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 11 of 61 <br />