r� ��r� ��
<br /> � 1,,, 1 .
<br /> � 3' I�I�INITY j ERD
<br /> TABLE 2A-1: STEEL OR CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TeaR-OFF)oR RECOVER
<br /> SYSTEM TYPE B-1: MECHARIICALLY ATTACHED BASE YNSULATION,BONDED TOP INSULATION,BONDED ROOF COVER
<br /> System Deck Base Insulation Layer Top Insulation Layer Roof Cover MDP
<br /> No. (See Note 1) Type Fasten Attach Type Attach Base Ply Cap �PS�
<br /> Min. 1.5-inch
<br /> Min.22 ga.,type B, EnergyGuard POLYISO See Note 1 per 2 Additional layer(s),min. 0.5-inch thick base 06500, SBS-SA or (Optional) SBS-TA,
<br /> SC-20 Grade 33 steel or LRF-M,M- Weather- SBS-TA,APP- -45.0*
<br /> structural concrete INSULATION, 2 ft2 insulation OSFA Watch XT TA APP-TA
<br /> EnergyGuard Ultre
<br /> Min.2-inch
<br /> Min.22 ga.,type B, EnergyGuard POLYISO See Note 1 per Additional layer(s), min.0.5-inch thick base 0B500, SBS-SA or (Optional) SBS-TA, *
<br /> SC-21 Grade 33 steel or LRF-M,M- Weather- SBS-TA,APP- -45,0
<br /> structural concrete INSULATION, 2 2.9 ft2 insulation OSFA Watch XT TA APP-TA
<br /> EnergyGuard Ultra
<br /> Min.2-inch
<br /> Min.22 ga.,type B, EnergyGuard POLYISO See Note 1 per 4 Additional layer(s),min. 1.5-inch thick base 06500, SBS-SA or (Optional) SBS-TA,
<br /> SC-22 Grede 33 steel or LRF-M,M- Weather- SBS-TA,APP- -45.0*
<br /> structural concrete INSULATION, 2 ft2 insulation OSFA Watch XT TA APP-TA
<br /> EnergyGuard Ultra
<br /> Min.22 ga.,type B, Min. 1.5-inch Optional additional layers of base (Optfonal)
<br /> EnergyGuard RA, See Note 1 per 2 Weather- SBS-TA, *
<br /> SC-23 Grade 33 steel or EnergyGuard RH, 2 ft2 insulatfon; Min.0.25-inch Dens Deck Prime OB500 yyatch XT SBS-TA,APP- APP-TA -45.0
<br /> structural concrete EnergyGuard RN or SECUROCK Gypsum-Fiber Roof Board TA
<br /> Min. 1.5-inch Optional additfonal layers,min. 0.5-inch
<br /> g _ 0B500, (Optional) SBS-TA
<br /> SC-24 Grade 33 steel or INSULATION, 2 ft2 Deck DuraGuard or SECUROCK Gypsum- ' APP-TA '
<br /> structural concrete EnergyGuard Ultre Fiber Roof Board OSFA� TA
<br /> Min. 1.5-inch Optional additlonal layers,min. 1-nich thick
<br /> Min.22 ga.,type B, EnergyGuard POLYISO See Note 1 per 2 base insulation; Min.0.25-inch Dens Deck OB500, yyeather- �Optional) SBS-TA,
<br /> SC-25 Grade 33 steel or INSULATION, 2 ft2 DuraGuard,Dens Deck Prime or SECUROCK LRF-M,M- Watch XT SBS-TA,APP- APP-TA -45.0*
<br /> structurel concrete EnergyGuard Ultre Gypsum-Fiber Roof Board OSFA TA
<br /> Min.2-inch Optional additional layers,min.0.5-inch
<br /> Min.22 ga.,type B, EnergyGuard POLYISO See Note 1 per base insulation; Min.0.25-inch Dens Deck OB500, (Optional) SBS-TA,
<br /> SC-26 Grade 33 steel or LRF-M,M- SBS-SA SBS-TA,APP- -45.0*
<br /> structural concrete INSULATION, 2 2.9 ft2 DuraGuard or SECUROCK Gypsum-Fiber OSFA TA APP-TA
<br /> EnergyGuard Ultra Roof Board
<br /> Min.22 ga.,type B, Min.2-inch Optional additional layers, min. 0.5-inch OB500, (Optional)
<br /> SC-27 Grede 33 steel or EnergyGuard POLYISO See Note 1 per base insulation; Min.0.25-inch Dens Deck Weather- SBS-TA
<br /> LRF-M,M- SBS-TA,APP- ' -45.0*
<br /> structurel concrete INSUTATION, 2 2.9 ft2 DuraGuard,Dens Deck Prime or SECUROCK �SFA Watch XT TA APP-TA
<br /> EnergyGuard Ultre Gypsum-Fiber Roof Board
<br /> Min.22 ga.,type B, Min.2-inch
<br /> EnergyGuard RA, See Note 1 per 4 Min.0.25-inch SECUROCK Gypsum-Fiber (Optional) *
<br /> SC-28 Grade 33 steel or EnergyGuard RH, 2 ft2 Roof Board OB500 SBS-SA SBS-SA SBS-SA -45.0
<br /> structural concrete EnergyGuard RN
<br /> Min.2-inch
<br /> Min.22 ga.,type B, EnergyGuard RA, See Note 1 per 4 Optional additional layers of base Weather- �Optional) SBS-TA, *
<br /> SC-29 Grade 33 steel or EnergyGuard RH, 2 ft2 insulation; Min.0.25-inch Dens Deck Prime 06500 N/atch XT SBS-TA,APP- APP_TA -45.0
<br /> structural concrete EnergyGuard RN or SECUROCK Gypsum-Fiber Roof Board TA
<br /> Exterior Research and Design,LLC.d/b/a Trinity�ERD Evaluation Report 01506.11.04-R12 for FL5680-R12
<br /> Certificate of Authorization#9503 Revision 12: 04/25/2014
<br /> Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 12 of 61
<br />
|